31 resultados para Monocular video


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of overt tobacco advertising and sponsorship bans is well established. The industry has responded to these bans by implementing “buzz” or “viral” marketing techniques, such as nightclub and dance party promotions. This paper analyses possible tobacco industry content on the burgeoning consumer generated media website, YouTube. Tobacco control efforts need to embrace this new medium in order to counter pro-smoking messages and maximize media advocacy opportunities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The eyes of the sandlance, Limnichthyes fasciatus (Creediidae. Teleostei) move independently and possess a refractive cornea, a convexiclivate fovea and a non-spherical lens giving rise to a wide separation of the nodal point from the axis of rotation of the eye much like that of a chameleon. To investigate this apparent convergence of the visual optics in these phylogenetically disparate species, we examine feeding behaviour and accommodation in the sandlance with special reference to the possibility that sandlances use accommodation as a depth cue to judge strike length. Frame-by-frame analysis of over 2000 strikes show a 100% success rate. Explosive strikes are completed in 50 ms over prey distances of four body lengths. Close-up video confirms that successful strikes can be initiated monocularly (both normally and after monocular occlusion) showing that binocular cues are not necessary to judge the length of a strike. Additional means of judging prey distance may also be derived from parallax information generated by rotation of the eye as suggested for chameleons. Using photorefraction on anaesthetised sandlances, accommodative changes were induced with acetylcholine and found to range between 120 D and 180 D at a speed of 600-720 D s(-1). The large range of accommodation (25% of the total power) is also thought to be mediated by corneal accommodation where the contraction of a unique cornealis muscle acts to change the corneal curvatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perceived depth was measured for three-types of stereograms with the colour/texture of half-occluded (monocular) regions either similar to or dissimilar to that of binocular regions or background. In a two-panel random dot stereogram the monocular region was filled with texture either similar or different to the far panel or left blank. In unpaired background stereograms the monocular region either matched the background or was different in colour or texture and in phantom stereograms the monocular region matched the partially occluded object or was a different colour or texture. In all three cases depth was considerably impaired when the monocular texture did not match either the background or the more distant surface. The content and context of monocular regions as well as their position are important in determining their role as occlusion cues and thus in three-dimensional layout. We compare coincidence and accidental view accounts of these effects. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High performance video codec is mandatory for multimedia applications such as video-on-demand and video conferencing. Recent research has proposed numerous video coding techniques to meet the requirement in bandwidth, delay, loss and Quality-of-Service (QoS). In this paper, we present our investigations on inter-subband self-similarity within the wavelet-decomposed video frames using neural networks, and study the performance of applying the spatial network model to all video frames over time. The goal of our proposed method is to restore the highest perceptual quality for video transmitted over a highly congested network. Our contributions in this paper are: (1) A new coding model with neural network based, inter-subband redundancy (ISR) prediction for video coding using wavelet (2) The performance of 1D and 2D ISR prediction, including multiple levels of wavelet decompositions. Our result shows a short-term quality enhancement may be obtained using both 1D and 2D ISR prediction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Howard and Duke (2003) generated stereograms with a grey transparent square offset from a vertical bar in one eye, and a vertical bar with a gap in the other eye. They argued that these displays were 'without conventional disparity' and that the metrical depth experienced was a new form of unpaired stereopsis due to 'transparency rather than occlusion'. Another possibility is that the perceived depth in these displays was obtained from horizontal contours. To test this possibility, we generated three displays that contained similar horizontal contourterminations, but were inconsistent with transparency. Reliable depth was seen in all stimuli. We conclude that in our stimuli, and those of Howard and Duke, transparency is not responsible for the perception of depth, which appears to be based instead on disparate horizontal contour terminations. Our results also show that disparate contours of opposite contrast polarity can generate depth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of the human eye to perceive depth was measured using a specially designed instrument. Visual acuity and both monocular and binocular stereoacuity were measured when viewing the instrument directly and via a videoconferencing link. Ten subjects with an average age of 32.5 years (range 24-50) took part in the study. The group mean visual acuity using both eyes under normal test conditions was -0.04 logMAR (Snellen 6/5) compared with 0.18 logMAR (Snellen 6/10) for the video-link. The mean stereoacuity using both eyes was 37 (SD 18) under normal test conditions. When a videoconferencing link was used, the mean stereoacuity fell to 1218 (SD 1203) using one eye and to 1651 (SD 1419) using both eyes. The ability to perceive depth remotely via a video-link was significantly decreased compared with normal test conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human nervous system constructs a Euclidean representation of near (personal) space by combining multiple sources of information (cues). We investigated the cues used for the representation of personal space in a patient with visual form agnosia (DF). Our results indicated that DF relies predominantly on binocular vergence information when determining the distance of a target despite the presence of other (retinal) cues. Notably, DF was able to construct an Euclidean representation of personal space from vergence alone. This finding supports previous assertions that vergence provides the nervous system with veridical information for the construction of personal space. The results from the current study, together with those of others, suggest that: (i) the ventral stream is responsible for extracting depth and distance information from monocular retinal cues (i.e. from shading, texture, perspective) and (ii) the dorsal stream has access to binocular information (from horizontal image disparities and vergence). These results also indicate that DF was not able to use size information to gauge target distance, suggesting that intact temporal cortex is necessary for learned size to influence distance processing. Our findings further suggest that in neurologically intact humans, object information extracted in the ventral pathway is combined with the products of dorsal stream processing for guiding prehension. Finally, we studied the size-distance paradox in visual form agnosia in order to explore the cognitive use of size information. The results of this experiment were consistent with a previous suggestion that the paradox is a cognitive phenomenon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this experiment was to determine the effectiveness of two video-based perceptual training approaches designed to improve the anticipatory skills of junior tennis players. Players were assigned equally to an explicit learning group, an implicit learning group, a placebo group or a control group. A progressive temporal occlusion paradigm was used to examine, before and after training, the ability of the players to predict the direction of an opponent's service in an in-vivo on-court setting. The players responded either through hitting a return stroke or making a verbal prediction of stroke direction. Results revealed that the implicit learning group, whose training required them to predict serve speed direction while viewing temporally occluded video footage of the return-of-serve scenario, significantly improved their prediction accuracy after the training intervention. However, this training effect dissipated after a 32 day unfilled retention interval. The explicit learning group, who received instructions about the specific aspects of the pre-contact service kinematics that are informative with respect to service direction, did not demonstrate any significant performance improvements after the intervention. This, together with the absence of any significant improvements for the placebo and control groups, demonstrated that the improvement observed for the implicit learning group was not a consequence of either expectancy or familiarity effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time motion analysis is extensively used to assess the demands of team sports. At present there is only limited information on the reliability of measurements using this analysis tool. The aim of this study was to establish the reliability of an individual observer's time motion analysis of rugby union. Ten elite level rugby players were individually tracked in Southern Hemisphere Super 12 matches using a digital video camera. The video footage was subsequently analysed by a single researcher on two occasions one month apart. The test-retest reliability was quantified as the typical error of measurement (TEM) and rated as either good (10% TEM). The total time spent in the individual movements of walking, jogging, striding, sprinting, static exertion and being stationary had moderate to poor reliability (5.8-11.1% TEM). The frequency of individual movements had good to poor reliability (4.3-13.6% TEM), while the mean duration of individual movements had moderate reliability (7.1-9.3% TEM). For the individual observer in the present investigation, time motion analysis was shown to be moderately reliable as an evaluation tool for examining the movement patterns of players in competitive rugby. These reliability values should be considered when assessing the movement patterns of rugby players within competition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have designed and tested an Internet-based video-phone suitable for use in the homes of families in need of paediatric palliative care services. The equipment uses an ordinary telephone line and includes a PC, Web camera and modem housed in a custom-made box. In initial field testing, six clinical consultations were conducted in a one-month trial of the videophone with a family in receipt of palliative care services who were living in the outer suburbs of Brisbane. Problems with variability in call quality-namely audio and video freezing, and audio break-up-prompted further laboratory testing. We completed a programme of over 250 test calls. Fixing modem connection parameters to use the V.34 modulation protocol at a set bandwidth of 24 kbit/s improved connection stability and the reliability of the video-phone. In subsequent field testing 47 of 50 calls (94%) connected without problems. The freezes that did occur were brief (with greatly reduced packet loss) and had little effect on the ability to communicate, unlike the problems arising in the home testing. The low-bandwidth Internet-based video-phone we have developed provides a feasible means of doing telemedicine in the home.