52 resultados para LUNG PROTECTIVE VENTILATION


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our aim was to determine whether antenatal corticosteroids improve perinatal adaptation of the pulmonary circulation in lambs with lung hypoplasia (LH). LH was induced in 12 ovine fetuses between 105 and 140 days gestation (term similar to 147 days); in 6 of these the ewe was given a single dose of betamethasone (11.4 mg im) 24 hr before delivery (LH + B). All lambs, including a control group (n = 6), were delivered at similar to 140 days and ventilated for 2 hr during which arterial pressures, pulmonary blood flow (PBF), and ventilating pressure and flow were recorded. During ventilation, respiratory system compliance was lower in both LH + B and LH groups than in controls. Pulmonary vascular resistance (PVR) was lower in LH + B lambs than in LH lambs and similar to controls; PBF was reduced in LH lambs but was restored to control levels by betamethasone. The mean density of small arteries of LH + B lambs was similar to that of LH lambs (P = 0.06) and lower than in controls; the thickness of the media of small pulmonary arteries from LH + B lambs was similar to that in LH lambs and thicker than in controls. VEGF mRNA levels were not different between groups. PDGF mRNA levels in LH + B lambs were higher than in LH lambs; a similar trend (P = 0.06) was seen for PECAM-1. SP-C mRNA levels were greater in both LH and LH + B lambs than in controls. Effects of betamethasone were greater on indices of pulmonary circulation than ventilation. We conclude that a single dose of maternal betamethasone 24 hr prior to birth has significant favorable effects on the postnatal adaptation of the pulmonary circulation in lambs with LH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We review a single surgeon and surgical centre's experience with congenital cystic adenomatoid malformation of the lung (CCAML) in relation to clinical spectrum, operative experience, and postoperative course. A retrospective hospital record review was done on surgically treated cases of CCAML over a 10-year period, focusing on number with antenatal diagnosis, spectrum of postnatal presentation, type of surgery performed, and outcome. Forty-seven patients from birth to 14 years of age underwent surgery for CCAML. Antenatal diagnosis (ante) was made in 30 cases. Of these, 10 became symptomatic before surgery. Six of the 17 postnatally-diagnosed (pnd) cases were an asymptomatic incidental finding. Overall, 16 were symptomatic in the 1st year of life, and five were symptomatic beyond 1 year of age. Symptoms varied from respiratory distress (seven ante, six pnd) to chronic cough (three, and recurrent chest infection (three ante, two pnd). All preoperative diagnoses were confirmed with chest CT. Most patients (25) were operated on before 3 months of age. Eleven were operated on in the first 2 weeks of life as emergency surgery for respiratory distress. The most common lobe involved was the right upper lobe (16), and lobectomy was performed in 42 cases, segmentectomy in four, and pneumonectomy in one. Seventeen cases were extubated immediately postoperatively; 29 required postoperative ventilation overnight, and nine needed more prolonged ventilation. Early postoperative complications included pneumothorax (two), pleural effusion (one), and chylous effusion (one). Late complications included recurrence in three cases (all segmentectomy), who then subsequently underwent lobectomy. There was one death from respiratory failure. Because there is an increasing trend in the detection of asymptomatic antenatally-diagnosed CCAML, consideration of early surgical excision to prevent complications is suggested by our series. CT scanning is mandatory for postnatal evaluation because chest x-ray could be normal. Safe elective excision after 3 months is supported by our low morbidity and less need for postoperative ventilation. Lobectomy is the procedure of choice to prevent recurrence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and objective: There are no data about the influence of anaesthetics on cardiovascular variables during pressure support ventilation of the lungs through the laryngeal mask airway. We compared propofol, sevoflurane and isoflurane for maintenance of anaesthesia with the ProSeal (R) laryngeal mask airway during pressure support ventilation. Methods: Sixty healthy adults undergoing peripheral musculo-skeletal surgery were randomized for maintenance with sevoflurane end-tidal 29%, isoflurane end-tidal 1.1% or propofol 6 mg kg(-1) h(-1) in oxygen 33% and air. Pressure support ventilation comprised positive end-expiratory pressure set at 5 cmH(2)O, and pressure support set 5 cmH(2)O above positive end-expiratory pressure. Pressure support was initiated when inspiration produced a 2 cmH(2)O reduction in airway pressure. A blinded observer recorded cardiorespiratory variables (heart rate, mean blood pressure, oxygen saturation, air-way occlusion pressure, respiratory rate, expired tidal volume, expired minute volume and end-tidal CO2), adverse events and emergence times. Results: Respiratory rate and minute volume were 10-21% lower, and end-tidal CO2 6-11% higher with the propofol group compared with the sevoflurane or isoflurane groups, but otherwise cardiorespiratory variables were similar among groups. No adverse events occurred in any group. Emergence times were longer with the propofol group compared with the sevoflurane or isoflurane groups (10 vs. 7 vs. 7 min). Conclusion: Lung ventilation is less effective and emergence times are longer with propofol than sevoflurane or isoflurane for maintenance of anaesthesia during pressure support ventilation with the ProSeal (R) laryngeal mask airway. However, these differences are small and of doubtful clinical importance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Smoke inhalation injuries are the leading cause of mortality from burn injury. Airway obstruction due to mucus plugging and bronchoconstriction can cause severe ventilation inhomogeneity and worsen hypoxia. Studies describing changes of viscoelastic characteristics of the lung after smoke inhalation are missing. We present results of a new smoke inhalation device in sheep and describe pathophysiological changes after smoke exposure. Fifteen female Merino ewes were anesthetized and intubated. Baseline data using electrical impedance tomography and multiple-breath inert-gas washout were obtained by measuring ventilation distribution, functional residual capacity, lung clearance index, dynamic compliance, and stress index. Ten sheep were exposed to standardized cotton smoke insufflations and five sheep to sham smoke insufflations. Measured carboxyhemoglobin before inhalation was 3.87 +/- 0.28% and 5 min after smoke was 61.5 +/- 2.1%, range 50-69.4% ( P < 0.001). Two hours after smoke functional residual capacity decreased from 1,773 +/- 226 to 1,006 +/- 129 ml and lung clearance index increased from 10.4 +/- 0.4 to 14.2 +/- 0.9. Dynamic compliance decreased from 56.6 +/- 5.5 to 32.8 +/- 3.2 ml/ cmH(2)O. Stress index increased from 0.994 +/- 0.009 to 1.081 +/- 0.011 ( P < 0.01) ( all means +/- SE, P < 0.05). Electrical impedance tomography showed a shift of ventilation from the dependent to the independent lung after smoke exposure. No significant change was seen in the sham group. Smoke inhalation caused immediate onset in pulmonary dysfunction and significant ventilation inhomogeneity. The smoke inhalation device as presented may be useful for interventional studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observation period and an EIT image describing regional relative impedance change is generated. Analysis of such an EIT image may be erroneous because it is based on an impedance signal that has several components. Most of the change in relative impedance in the chest is caused by air movement but other physiological events such as cardiac activity change in end expiratory level or pressure swings originating from a ventilator circuit can influence the impedance signal. We obtained EIT images and signals in spontaneously breathing healthy adults, in extremely prematurely born infants on continuous positive airway pressure and in ventilated sheep on conventional mechanical or high frequency oscillatory ventilation (HFOV). Data were analyzed in the frequency domain and results presented after band pass filtering within the frequency range of the physiological event of interest. Band pass filtering of EIT data is necessary in premature infants and on HFOV to differentiate and eliminate relative impedance changes caused by physiological events other than the one of interest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Caudal block results in a motor blockade that can reduce abdominal wall tension. This could interact with the balance between chest wall and lung recoil pressure and tension of the diaphragm, which determines the static resting volume of the lung. On this rationale, we hypothesised that caudal block causes an increase in functional residual capacity and ventilation distribution in anaesthetised children. Fifty-two healthy children (15-30 kg, 3-8 years of age) undergoing elective surgery with general anaesthesia and caudal block were studied and randomly allocated to two groups: caudal block or control. Following induction of anaesthesia, the first measurement was obtained in the supine position (baseline). All children were then turned to the left lateral position and patients in the caudal block group received a caudal block with bupivacaine. No intervention took place in the control group. After 15 nun in the supine position, the second assessment was performed. Functional residual capacity and parameters of ventilation distribution were calculated by a blinded reviewer. Functional residual capacity was similar at baseline in both groups. In the caudal block group, the capacity increased significantly (p < 0.0001) following caudal block, while in the control group, it remained unchanged. In both groups, parameters of ventilation distribution were consistent with the changes in functional residual capacity. Caudal block resulted in a significant increase in functional residual capacity and improvement in ventilation homogeneity in comparison with the control group. This indicates that caudal block might have a beneficial effect on gas exchange in anaesthetised, spontaneously breathing preschool-aged children with healthy lungs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of individual viral proteins in the immune response to bluetongue virus (BTV) is not clearly understood. To investigate the contributions of the outer capsid proteins, VP2 and VP5, and possible interactions between them, these proteins were expressed from recombinant vaccinia viruses either as individual proteins or together in double recombinants, or with the core protein VP7 in a triple recombinant. Comparison of the immunogenicity of the vaccinia expressed proteins with BTV expressed proteins was carried out by inoculation of rabbits and sheep. Each of the recombinants was capable of stimulating an anti-BTV antibody response, although there was a wide range in the level of response between animals and species. Vaccinia-expressed VP2 was poorly immunogenic, particularly in rabbits. VP5, on the whole, stimulated higher ELISA titers in rabbits and sheep and in some animals in both species was able to stimulate virus neutralizing antibodies. When the protective efficacy of VP2 and VP5 was tested in sheep, vaccinia-expressed VP2, VP5 and VP2 + VP5 were protective, with the most consistent protection being in groups immunized with both proteins. (C) 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molecular mechanism of how insects recognize intruding microorganisms and parasites and distinguish them from own body structures is not well known. We explored evolutionary adaptations in an insect parasitoid host interaction to identify components that interfere with the recognition of foreign objects and cellular encapsulation. Because some parasitoids provide protection for the developing wasp in the absence of an overt suppression of the insect host defense, we analyzed the surface of eggs and symbiotic viruses for protective properties. Here we report on the molecular cloning of a 32-kDa protein (Crp32) that is one of the major protective components. It is produced in the calyx cells of the female wasp ovaries and attached to the surface of the egg and other particles including polydnaviruses. The recombinant protein confers protection to coated objects in a cellular encapsulation assay suggesting that a layer of Crp32 may prevent cellular encapsulation reactions by a local inactivation of the host defense system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been shown previously that recombinant virus-like particles (VLPs) of papillomavirus can induce VLP-specific humoral and cellular immune responses following parenteral administration. To test whether mucosal administration of bovine papillomavirus type 1 (BPV1) VLPs could produce mucosal as well as systemic immune responses to VLPs, 50 mu g chimeric BPV1 VLPs containing an HPV16 E7 CTL epitope (BPVL1/E7 VLP) was administered intranasally to mice. After two immunisations, L1-specific serum IgG and IgA were observed. L1-specific IgG and IgA were also found in respiratory and vaginal secretions. Both serum and mucosal antibody inhibited papillomavirus VLP-induced agglutination of RBC, indicating that the antibody induced by mucosal immunisation may recognize conformational determinants associated with virus neutralisation. For comparison, VLPs were given intramuscularly, and systemic and mucosal immune responses were generally comparable following systemic or mucosal delivery. However, intranasal administration of VLP induced significantly higher local IgA response in lung, suggesting that mucosally delivered HPV VLP may be more effective for mediating local mucosal immune responses. Intranasal immunisation with HPV6b L1 VLP produced VLP-specific T proliferative responses in splenocytes, and immunisation with BPVL1 VLP containing an HPV16 E7 CTL epitope induced E7-specific CTL responses. We conclude that immunisation with papillomavirus VLPs via mucosal and intramuscular routes, without adjuvant, can elicit specific antibody at mucosal surfaces and also systemic VLP epitope specific T cell responses. These findings suggest that mucosally delivered VLPs may offer an alternative HPV VLP vaccine strategy for inducing protective humoral immunity to anogenital HPV infection, together with cell-mediated immune responses to eliminate any cells which become infected. (C) 1998 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obstruction of the fetal trachea is a potent stimulus for fetal lung growth and may have therapeutic potential in human fetuses with lung hypoplasia. However, the effects of increased lung expansion on lung development near midgestation, which is the preferred timing for fetal intervention, have not been well studied. Our aim was to determine the effects of increased lung expansion on lung development at 75-90 d of gestation in fetal sheep. In three groups of fetuses (n = 4 for each), the trachea was occluded for either 10 [10-d tracheal occlusion (TO) group] or 15 d (15-d TO group) or left intact (control fetuses). TO for both 10 and 15 d caused fetal hydrops, resulting in significantly increased fetal body weights. Both periods of TO significantly increased total lung DNA contents from 99.8 +/- 10.1 to 246.0 +/- 5.3 and 246.9 +/- 48.7 mg in 10- and 15-d TO fetuses, respectively. TO for 10 and 15 d also increased airspace diameter, although the percentage of lung occupied by airspace was not increased in 10-d TO fetuses due to large increases in interairway distances; this resulted from a large increase in mesenchymal tissue. The interairway distances at 15 d of TO were reduced compared with the 10-d value but were still similar to 30% larger than control values. We conclude that TO at

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To review the epidemiological evidence for the association between passive smoking and lung cancer. Method: Primary studies and meta-analyses examining the relationship between passive smoking and lung cancer were identified through a computerised literature search of Medline and Embase, secondary references, and experts in the field of passive smoking. Primary studies meeting the inclusion criteria were meta-analysed. Results From 1981 to the end of 1999 there have been 76 primary epidemiological studies of passive smoking and lung cancer, and 20 meta-analyses. There were 43 primary studies that met the inclusion criteria for this meta-analysis; more studies than previous assessments. The pooled relative risk (RR) for never-smoking women exposed to environmental tobacco smoke (ETS) from spouses, compared with unexposed never-smoking women was 1.29 (95% CI 1.17-1.43). Sequential cumulative meta-analysed results for each year from 1981 were calculated: since 1992 the RR has been greater than 1.25. For Western industrialised countries the RR for never-smoking women exposed to ETS compared with unexposed never-smoking women, was 1.21 (95% CI 1.10-1.33). Previously published international spousal meta-analyses have all produced statistically significant RRs greater than 1.17. Conclusions The abundance of evidence in this paper, and the consistency of findings across domestic and workplace primary studies, dosimetric extrapolations and meta-analyses, clearly indicates that non-smokers exposed to ETS are at increased risk of lung cancer. Implications: The recommended public health policy is for a total ban on smoking in enclosed public places and work sites.