130 resultados para Anesthetic techniques, regional: subarachnoid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Postoperative cognitive dysfunction (POCD) after coronary artery bypass graft surgery is a common complication for which, despite many clinical investigations, no definitive etiology has been found. The current use of both high and low-dose fentanyl as anesthetic techniques allowed us to investigate the effect of fentanyl on the incidence of POCD. Methods. Three hundred fifty patients scheduled to undergo elective coronary artery bypass graft surgery were randomized to receive either high-dose fentanyl (50 mu g/kg) or low-dose fentanyl (10 mu g/kg) as the basis of the anesthetic. All patients underwent neuropsychological testing before surgery and at 1 week, 3 months, and 12 months after surgery. Results. One hundred sixty-eight patients in the low-dose group and 158 patients in the high-dose group were included in the final analysis. Neuropsychological testing was performed on 88%, 93%, and 92% of patients at 1 week, 3 months, and 12 months, respectively. There was no difference between group mean scores at any of the three testing times. Analysis of individual patients by the 20% rule did not detect any differences between groups. The one SD rule, which has fewer false-positive results, detected significantly more patients with POCD in the low-dose group than in the high-dose group at 1 week (23.6% vs. 13.7%; P = 0.03) but not at the other testing times. Patients with POCD spent an average of 1.2 days longer in the hospital than those without POCD (P = 0.021). Conclusions: High-dose fentanyl is not associated with a difference in the incidence of POCD at 3 or 12 months after surgery. Low-dose fentanyl leads to shorter postoperative ventilation times and may be associated with a greater incidence of POCD 1 week after surgery. Early POCD is associated with an increased duration of stay in the hospital.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The left ventricular response to dobutamine may be quantified using tissue Doppler measurement of myocardial velocity or displacement or 3-dimensional echocardiography to measure ventricular volume and ejection fraction. This study sought to explore the accuracy of these methods for predicting segmental and global responses to therapy. Standard dobutamine and 3-dimensional echocardiography were performed in 92 consecutive patients with abnormal left ventricular function at rest. Recovery of function was defined by comparison with follow-up echocardiography at rest 5 months later. Segments that showed improved regional function at follow-up showed a higher increment in peak tissue Doppler velocity with dobutamine therapy than in nonviable segments (1.2 +/- 0.4 vs 0.3 +/- 0.2 cm/s, p = 0.001). Similarly, patients who showed a > 5% improvement of ejection fraction at follow-up showed a greater displacement response to dobutamine (6.9 +/- 3.2 vs 2.1 +/- 2.3 mm, p = 0.001), as well as a higher rate of ejection fraction, response to dobutamine (9 +/- 3% vs 2 +/- 2%, p = 0.001). The optimal cutoff values for predicting subsequent recovery of function at rest were an increment of peak velocity > 1 cm/s, >5 mm of displacement, and a >5% improvement of ejection fraction with low-dose dobutamine. (C) 2003 by Excerpta Medica, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental mechanical sieving methods are applied to samples of shellfish remains from three sites in southeast Queensland, Seven Mile Creek Mound, Sandstone Point and One-Tree, to test the efficacy of various recovery and quantification procedures commonly applied to shellfish assemblages in Australia. There has been considerable debate regarding the most appropriate sieve sizes and quantification methods that should be applied in the recovery of vertebrate faunal remains. Few studies, however, have addressed the impact of recovery and quantification methods on the interpretation of invertebrates, specifically shellfish remains. In this study, five shellfish taxa representing four bivalves (Anadara trapezia, Trichomya hirsutus, Saccostrea glomerata, Donax deltoides) and one gastropod (Pyrazus ebeninus) common in eastern Australian midden assemblages are sieved through 10mm, 6.3mm and 3.15mm mesh. Results are quantified using MNI, NISP and weight. Analyses indicate that different structural properties and pre- and postdepositional factors affect recovery rates. Fragile taxa (T. hirsutus) or those with foliated structure (S. glomerata) tend to be overrepresented by NISP measures in smaller sieve fractions, while more robust taxa (A. trapezia and P. ebeninus) tend to be overrepresented by weight measures. Results demonstrate that for all quantification methods tested a 3mm sieve should be used on all sites to allow for regional comparability and to effectively collect all available information about the shellfish remains.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Echocardiographic analysis of regional left ventricular function is based upon the assessment of radial motion. Long-axis motion is an important contributor to overall function. but has been difficult to evaluate clinically until the recent development of tissue Doppler techniques. We sought to compare the standard visual assessment of radial motion with quantitative tissue Doppler measurement of peak systolic velocity. timing and strain rate (SRI) in 104 patients with known or suspected coronary artery disease undergoing dobutamine stress echocardiography (DbE). A standard DbE protocol was used with colour tissue Doppler images acquired in digital cine-loop format. peak systolic velocity (PSV), time to peak velocity (TPV) and SRI were assessed off-line by an independent operator. Wall motion was assessed by an experienced reader. Mean PSV, TPV and SRI values were compared with wall motion and the presence of coronary artery disease by angiography. A further analysis included assessing the extent of jeopardized myocardium by comparing average values of PSV, TPV and SRI against the previously validated angiographic score. Segments identified as having normal and abnormal radial wall motion showed significant differences in mean PSV (7.9 +/- 3.8 and 5.9 +/- 3.3 cm/s respectively; P < 0.001), TPV (84 40 and 95 +/- 48 ms respectively; P = 0.005) and SRI (- 1.45 +/- 0.5 and - 1.1 +/- 0.9 s(-1) respectively; P < 0.001). The presence of a stenosed subtending coronary artery was also associated with significant differences from normally perfused segments for mean PSV (8.1 3.4 compared with 5.7 +/- 3.7 cm/s; P < 0.001), TPV (78 50 compared with 92 +/- 45 ms; P < 0.001) and SRI (- 1.35 0.5 compared with - 1.20 +/- 0.4 s(-1); P = 0.05). PSV, TPV and SRI also varied significantly according to the extent of jeopardized myocardium within a vascular territory. These results suggest that peak systolic velocity, timing of contraction and SRI reflect the underlying physiological characteristics of the regional myocardium during DbE, and may potentially allow objective analysis of wall motion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regional planners, policy makers and policing agencies all recognize the importance of better understanding the dynamics of crime. Theoretical and application-oriented approaches which provide insights into why and where crimes take place are much sought after. Geographic information systems and spatial analysis techniques, in particular, are proving to be essential or studying criminal activity. However, the capabilities of these quantitative methods continue to evolve. This paper explores the use of geographic information systems and spatial analysis approaches for examining crime occurrence in Brisbane, Australia. The analysis highlights novel capabilities for the analysis of crime in urban regions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have tested an alternative method of delivering health services to regional areas of Queensland. By integrating telepaediatrics into an existing outreach programme for children with diabetes and endocrine conditions, we were able to reduce travel for specialist hospital staff while maintaining (and sometimes increasing) the contact patients had with the specialist team. In the first 28 months, we facilitated 160 patient consultations and 10 education sessions via videoconference through the telepaediatric service. By the end of the study, site visits were taking place annually and routine videoconference clinics were scheduled quarterly for the review of new patients and follow-up. Telepaediatric services in endocrinology and diabetes were established at three levels: the coordination of routine specialist clinics via videoconference; ad hoc patient consultations for collaborative management during acute presentations and at times of urgent clinical need; and the delivery of education to staff and patients throughout the state. The net result was improved access to specialist services from rural and remote areas of Queensland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The planning and management of water resources in the Pioneer Valley, north-eastern Australia requires a tool for assessing the impact of groundwater and stream abstractions on water supply reliabilities and environmental flows in Sandy Creek (the main surface water system studied). Consequently, a fully coupled stream-aquifer model has been constructed using the code MODHMS, calibrated to near-stream observations of watertable behaviour and multiple components of gauged stream flow. This model has been tested using other methods of estimation, including stream depletion analysis and radon isotope tracer sampling. The coarseness of spatial discretisation, which is required for practical reasons of computational efficiency, limits the model's capacity to simulate small-scale processes (e.g., near-stream groundwater pumping, bank storage effects), and alternative approaches are required to complement the model's range of applicability. Model predictions of groundwater influx to Sandy Creek are compared with baseflow estimates from three different hydrograph separation techniques, which were found to be unable to reflect the dynamics of Sandy Creek stream-aquifer interactions. The model was also used to infer changes in the water balance of the system caused by historical land use change. This led to constraints on the recharge distribution which can be implemented to improve model calibration performance. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tissue Doppler (TD) assessment of dysynchrony (DYS) is established in evaluation for bi-ventricular pacing. Time to regional minimal volume by real-time 3D echo (3D) has been applied to DYS. 3D offers simultaneous assessment of all segments and may limit errors in localization of maximum delay due to off-axis images.We compared TD and 3D for assessment of DYS. 27 patients with ischaemic cardiomyopathy (aged 60±11 years, 85% male) underwent TD with generation of regional velocity curves. The interval between QRS onset and maximal systolic velocity (TTV) was measured in 6 basal and 6 mid-cavity segments. Onthe same day,3Dwas performed and data analysed offline with Q-Lab software (Philips, Andover, MA). Using 12 analogous regional time-volume curves time to minimal volume (T3D)was calculated. The standard deviation (S.D.) between segments in TTV and T3D was calculated as a measure ofDYS. In 7 patients itwas not possible to measureT3D due to poor images. In the remaining 20, LV diastolic volume, systolic volume and EF were 128±35 ml, 68±23 ml and 46±13%, respectively. Mean TTV was less than mean T3D (150±33ms versus 348±54 ms; p < 0.01). The intrapatient range was 20–210ms for TTV and 0–410ms for T3D. Of 9 patients (45%) with significantDYS (S.D. TTV > 32 ms), S.D. T3D was 69±37ms compared to 48±34ms in those without DYS (p = ns). In DYS patients there was concordance of the most delayed segment in 4 (44%) cases.Therefore, different techniques for assessing DYS are not directly comparable. Specific cut-offs for DYS are needed for each technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We sought to determine the relative impact of myocardial scar and viability on post-infarct left ventricular (LV) remodeling in medically-treated patients with LV dysfunction. Forty patients with chronic ischemic heart disease (age 64±9, EF 40±11%) underwent rest-redistribution Tl201 SPECT (scar = 50% transmural extent), A global index of scarring for each patient (CMR scar score) was calculated as the sum of transmural extent scores in all segts. LV end diastolic volumes (LVEDV) and LV end systolic volumes (LVESV) were measured by real-time threedimensional echo at baseline and median of 12 months follow-up. There was a significant positive correlation between change in LVEDV with number of scar segts by all three imaging techniques (LVEDV: SPECT scar, r = 0.62, p < 0.001; DbE scar, r = 0.57, p < 0.001; CMR scar, r = 0.52, p < 0.001) but change in LV volumes did not the correlate with number of viable segments. ROC curve analysis showed that remodeling (LVEDV> 15%) was predicted bySPECTscars(AUC= 0.79),DbEscars(AUC= 0.76),CMR scars (AUC= 0.70), and CMR scar score (AUC 0.72). There were no significant differences between any of the ROC curves (Z score

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regional tourism organizations (RTOs) plays a central role in planning, coordinating and marketing tourism in many areas, including Queensland, Australia. RTOs rely on interaction with a network of other organizations for their efficient functioning. This paper describes an exploratory case study that develops a method for use of social network analysis techniques to analyse the inter-organizational network in one RTO region in Queensland. Results indicate that differences exist in the structure of inter-organizational links between commercial tourism organizations and planning organizations, between tourism organizations and other sectoral clusters, and between organizations at local, regional and state levels. The results highlight areas or improvement in the role and responsibilities of RTOs in Queensland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A piecewise uniform fitted mesh method turns out to be sufficient for the solution of a surprisingly wide variety of singularly perturbed problems involving steep gradients. The technique is applied to a model of adsorption in bidisperse solids for which two fitted mesh techniques, a fitted-mesh finite difference method (FMFDM) and fitted mesh collocation method (FMCM) are presented. A combination (FMCMD) of FMCM and the DASSL integration package is found to be most effective in solving the problems. Numerical solutions (FMFDM and FMCMD) were found to match the analytical solution when the adsorption isotherm is linear, even under conditions involving steep gradients for which global collocation fails. In particular, FMCMD is highly efficient for macropore diffusion control or micropore diffusion control. These techniques are simple and there is no limit on the range of the parameters. The techniques can be applied to a variety of adsorption and desorption problems in bidisperse solids with non-linear isotherm and for arbitrary particle geometry.