25 resultados para Absorption of light
Resumo:
The development of solutions that prevent dehydration or promote adequate re-hydration play a vital role in preventing fatigue during exercise, however, the methods commonly used to assess the hydration ability of such solutions are invasive and often assess the components of absorption separately. This paper describes using a non-invasive deuterium tracer technique that assesses gastric emptying and intestinal absorption simultaneously to evaluate the uptake of water during rest and exercise. The kinetics of absorption are further examined by mathematical modelling of the data generated. For the rest group, 0.05 g/kg of body weight of deuterium, contained in gelatine capsules, was ingested with ordinary tap water and saliva samples were collected every 5 min for one hour while the subject remained seated. The deuterium was administered as above for the exercise group but sample collection was during one hour of exercise on a treadmill at 55% of the subject's maximum heart rate. The enrichment data for each subject were mathematically modelled and the parameters obtained were compared across groups using an independent samples t-test. Compared with the rest condition, the exercise group showed delayed absorption of water as indicated by significant differences for the modelling parameters t(2), t(1/2), maximum absorption rate and solution absorption amount at t(1). Labelling with a deuterium tracer is a good measure of the relative rate ingested fluids are absorbed by the body. Mathematical modelling of the data generates rates of maximum absorption and allows calculation of the percentage of the solution that is absorbed at any given time during the testing period. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
Objective-To investigate in vitro transdermal absorption of fentanyl from patches through skin samples obtained from various anatomic regions of dogs. Sample Population-Skin samples from 5 Greyhounds. Procedure-Skin samples from the dogs' thoracic, neck, and groin regions were collected postmortem and frozen. After samples were thawed, circular sections were cut and placed in Franz-type diffusion cells in a water bath (32degreesC). A commercial fentanyl patch, attached to an acetate strip with a circular hole, was applied to each skin sample. Cellulose strips were used as control membranes. Samples of receptor fluid in the diffusion cells were collected at intervals for 48 hours, and fentanyl concentrations were analyzed by use of high-performance liquid chromatography. Results-Mean +/- SD release rate of fentanyl from the patch, defined by its absorption rate through the non-rate-limiting cellulose membrane, was linear during the first 8 hours (2.01 +/- 0.05 pg/cm(2) of cellulose membrane/h) and then decreased. Fentanyl passed through skin from the groin region at a faster rate and with a significantly shorter lag time, compared with findings in neck or thoracic skin samples. Conclusions and Clinical Relevance-In vitro, fentanyl from a patch was absorbed more quickly and to a greater extent through skin collected from the groin region of dogs, compared with skin samples from the thoracic and neck regions. Placement of fentanyl patches in the groin region of dogs may decrease the lag time to achieve analgesia perioperatively; however, in vivo studies are necessary to confirm these findings.
Resumo:
The effect of region of application on the percutaneous penetration of solutes with differing lipophilicity was investigated in canine skin. Skin from the thorax, neck, back, groin, and axilla regions was harvested from Greyhound dogs and placed in Franz-type diffusion cells. Radiolabelled (C-14) ethanol (Log P 0.19) or hexanol (Log P 1.94) was applied to each skin section for a total of 5 h. The permeability coefficient (k(P), cm h(-1)) and residue of alcohol remaining in the skin were significantly (P = 0.001) higher for hexanol compared to ethanol. In contrast, ethanol had a far greater maximum flux (J(max), mol (cm(2))(-1) h(-1)) than hexanol (P = 0.001). A comparison of regional differences shows the k(P) and Jmax for ethanol in the groin was significantly lower (P = 0.035) than the back. The k(P) and Jmax for hexanol were significantly higher (P = 0.001) in the axilla than the other four skin sites. An understanding of factors influencing percutaneous drug movement is important when formulating topical preparations for the dog. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
We consider the task of estimating the randomly fluctuating phase of a continuous-wave beam of light. Using the theory of quantum parameter estimation, we show that this can be done more accurately when feedback is used (adaptive phase estimation) than by any scheme not involving feedback (nonadaptive phase estimation) in which the beam is measured as it arrives at the detector. Such schemes not involving feedback include all those based on heterodyne detection or instantaneous canonical phase measurements. We also demonstrate that the superior accuracy of adaptive phase estimation is present in a regime conducive to observing it experimentally.
Resumo:
We examine here the relative importance of different contributions to transport of light gases in single walled carbon nanotubes, using methane and hydrogen as examples. Transport coefficients at 298 K are determined using molecular dynamics simulation with atomistic models of the nanotube wall, from which the diffusive and viscous contributions are resolved using a recent approach that provides an explicit expression for the latter. We also exploit an exact theory for the transport of Lennard-Jones fluids at low density considering diffuse reflection at the tube wall, thereby permitting the estimation of Maxwell coefficients for the wall reflection. It is found that reflection from the carbon nanotube wall is nearly specular, as a result of which slip flow dominates, and the viscous contribution is small in comparison, even for a tube as large as 8.1 nm in diameter. The reflection coefficient for hydrogen is 3-6 times as large as that for methane in tubes of 1.36 nm diameter, indicating less specular reflection for hydrogen and greater sensitivity to atomic detail of the surface. This reconciles results showing that transport coefficients for hydrogen and methane, obtained in simulation, are comparable in tubes of this size. With increase in adsorbate density, the reflection coefficient increases, suggesting that adsorbate interactions near the wall serve to roughen the local potential energy landscape perceived by fluid molecules.
Resumo:
A review with 93 references. Heparins are high molecular weight, hydrophilic polyanions, which are unstable under acidic conditions; and therefore they exhibit poor oral bioavailability. Consequently they must be administered via the parenteral route which is expensive, inconvenient, and limits use by outpatients. The development of an oral form of heparin is warranted. This review examined the literature, mostly published between January 2000 and January 2005, pertaining to the gastrointestinal absorption of heparin by lipidization or coadministration with penetration enhancers. A lipidization strategy that was examined involved conjugation of low molecular weight heparin with deoxycholic acid. The majority of studies examined the ability of different formulations, typically utilizing penetration enhancers, to improve heparin bioavailability. The penetration enhancers used included fatty acids, Labrasol™, Gelucire 44/14™, polycationic lipophilic-core dendrons, saponins, mono-N-carboxymethyl chitosan, Carbopol® 934P, a combination of thiolated polycarbophil and glutathione, polymeric nanoparticles, polymeric microparticles, sodium N-[8-(2-hydroxybenzoyl) amino]caprylate (SNAC), and sodium N-[10-(2-hydroxybenzoyl)amino]decanoate (SNAD). The variety of models used and doses of heparin/penetration enhancers applied, however, made it difficult to compare the results between studies. Nevertheless, all of the reviewed drug delivery systems showed therapeutic value and confirmation of the promising results obtained from animal studies, by progression to clinical trials, is necessary. Overall, progress has been made in the quest for an oral heparin formulation.
Resumo:
Objective-To determine the effects of various vehicles on the penetration and retention of hydrocortisone applied to canine skin. Sample Population-20 canine skin samples obtained from the thorax, neck, and groin regions of 5 Greyhounds. Procedure-Skin was harvested from dogs after euthanasia and stored at -20 degrees C until required. The skin was then defrosted and placed into diffusion cells, which were maintained at approximately 32 degrees C by a water bath. Saturated solutions of hydrocortisone that contained trace amounts of radiolabelled [C-14]-hydrocortisone in each vehicle (ie, PBS solution [PBSS] alone, 50% ethanol [EtOH] in PBSS [wt/wt], and 50% propylene glycol in PBSS [wt/wt]) were applied to the outer (stratum corneum) surface of each skin sample, and aliquots of receptor fluid were collected for 24 hours and analyzed for hydrocortisone. Results-The maximum flux of hydrocortisone was significantly higher for all sites when dissolved in a vehicle containing 50% EtOH, compared with PBSS alone or 50% propylene glycol, with differences more prominent in skin from the neck region. In contrast, higher residues of hydrocortisone were found remaining within the skin when PBSS alone was used as a vehicle, particularly in skin from the thorax and neck. Conclusions and Clinical Relevance-Penetration of topically applied hydrocortisone is enhanced when EtOH is used in vehicle formulation. Significant regional differences (ie, among the thorax, neck, and groin areas) are also found in the transdermal penetration and skin retention of hydrocortisone. Variability in clinical response to hydrocortisone can be expected in relation to formulation design and site of application.
Resumo:
We report on a new experimental technique suitable for measurement of light-activated processes, such as fluorophore transport. The usefulness of this technique is derived from its capacity to decouple the imaging and activation processes, allowing fluorescent imaging of fluorophore transport at a convenient activation wavelength. We demonstrate the efficiency of this new technique in determination of the action spectrum of the light mediated transport of rhodamine 123 into the parasitic protozoan Giardia duodenalis. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
Resumo:
The skin localization of steroids following topical application is largely unknown. We determined the distribution of five steroids in human skin using excised epidermal, dermal, and full-thickness membranes in vitro. There was no significant difference in steroid maximum flux through epidermal and full-thickness membranes, other than significantly lower fluxes for the most polar steroid, aldosterone. Hydrocortisone had the highest dermal diffusivity and dermal penetration, and the accumulation of hydrocortisone and corticosterone was higher than that of the other steroids. Slower penetration and higher accumulation in the viable epidermis of progesterone in full-thickness skin were consistent with dermal penetration limitation effects associated with high lipophilicity. Copyright (c) 2006 S. Karger AG, Basel