8 resultados para Three phase rectifier system
em SAPIENTIA - Universidade do Algarve - Portugal
Resumo:
This paper presents the development and implementation of a digital simulation model of a threephase, three-leg, three-winding power transformer. The proposed model, implemented in MATLAB environment, is based on the simultaneous analysis of both magnetic and electric lumped-parameters equivalents circuits, and it is intended to study its adequacy to incorporate, at a later stage, the influences of the occurrence of windings interturn short-circuit faults. Both simulation and laboratory tests results, obtained so far, for a three-phase, 6 kVA transformer, demonstrate the adequacy of the model under normal operating conditions.
Resumo:
This paper presents the development and implementation of a digital simulation model of a three-phase, three-leg, power transformer. The proposed model, implemented in MATLAB environment, is based on the physical concept of representing windings as mutually coupled coils, and it is intended to study its adequacy to incorporate, at a later stage, the influences of the occurrence of windings inter- turn short-circuits. Both simulation and laboratory tests results, obtained so far, for a three-phase, 6 kVA transformer, demonstrate the adequacy of the model under normal operating conditions.
Resumo:
This paper presents a non-invasive approach for diagnosing winding insulation failures in three-phase transformers, which is based on the on-line monitoring of the primary and secondary current Park's Vector. Experimental and simulated results demonstrate the effectiveness of the proposed technique, for detecting winding inter-turn insulation faults in operating three-phase transformers.
Resumo:
This paper presents the development of a new approach for diagnosing the occurrence of inter-turn short-circuits in the windings of three-phase transformers, which is based on the on-line monitoring of the on-load exciting current Park's Vector patterns. Experimental and simulated results demonstrate the effectiveness of the proposed technique for detecting winding inter-turn insulation faults in operating three-phase transformers.
Resumo:
In the past few years, a considerable research effort has been devoted to the development of transformer digital models in order to simulate its behaviour under transient and abnormal operating conditions. Although many three-phase transformer models have been presented in the literature, there is a surprisingly lack of studies regarding the incorporation of winding faults. This paper presents a coupled electromagnetic transformer model for the study of winding inter-turn short-circuits. Particular attention will be given to the model parameters determination, for both healthy and faulty operating conditions. Experimental and simulation test results are presented in the paper, demonstrating the adequacy of the model as well as the methodologies for the parameters determination.
Resumo:
This paper addresses the subject of condition monitoring and diagnostics of power transformers. The main results of two reliability surveys, carried out under the auspices of CIGRE and IEEE in order to assemble objective data on the performance of transformers in service, are presented, providing useful information on the main causes of transformer failures, the most likely affected components and the related outages times. A survey of the most important methods, actually in use, for condition monitoring and diagnostics of power transformers is also given, which stresses the need for the development of new diagnostic methods, that can be applied without taking the transformers out of service, and that can also provide a fault severity criteria, in particular for determining transformers windings integrity. Preliminary results, concerning the on-going research activity on the development of a new approach for inter-turn winding fault diagnosis in three-phase transformers, are also reported in the paper.
Resumo:
This paper addresses the subject of condition monitoring and diagnostics of power transformers. The main results of two reliability surveys, carried out under the auspices of CIGRE and IEEE in order to assemble objective data on the performance of transformers in service, are presented, providing useful information on the main causes of transformer failures, the most likely affected components and the related outages times. A survey of the most important methods, actually in use, for condition monitoring and diagnostics of power transformers is also given, which stresses the need for the development of new diagnostic methods, that can be applied without taking the transformers out of service, and that can also provide a fault severity criteria, in particular for determining transformers windings integrity. Preliminary results, concerning the on-going research activity on the development of a new approach for inter-turn winding fault diagnosis in three-phase transformers, are also reported in the paper.
Resumo:
Polystichum drepanum (Sw) C. Presl is a threatened fern endemic to a few forest areas in the north-west of Madeira Island. The aims of this work were to establish suitable culture conditions for in vitro germination of spores, and to evaluate short-term storage conditions for P drepanum spores. The highest frequency of germination was obtained in Murishage and Skoog (MS) liquid medium, without agitation. However, gametophytes maintained in MS liquid medium did not grow and, after 4 weeks, became anoxic and died. Thus, after germination in liquid medium, gametophytes were transferred to an MS double-phase culture system for further growth. The effects of storage period, temperature, and relative humidity during storage on in vitro spore germination were studied. Spore viability was assessed after 2, 4 and 6 months, and high viability (> 94%) was observed in all the assays. However, germination capability decreased with increased storage periods. The number of sporophytes obtained also decreased with prolonged storage periods. The results indicate that spores of R drepanum stored for 4 months at 21 degrees C maintain high viability and high germination frequency. ne sporophytes obtained were acclimatised in a mixture of peat and vermiculite [2:1 (v/v)] under high relative humidity (90-95%). Seventy-five sporophytes were successfully acclimatised to ex vitro conditions and showed active growth in the glasshouse.