4 resultados para TUMOR BLOOD-FLOW
em SAPIENTIA - Universidade do Algarve - Portugal
Resumo:
The work described here is part of a research program aiming to increase the sensitivity to disease detection using Doppler ultrasound by reducing the effects to the measurement procedure on the estimation of blood velocity and detection of flow disturbance.
Resumo:
Aiming at time-spatial characterization of tissue temperature when ultrasound is applied for thermal therapeutic proposes two experiments were developed considering gel-based phantoms, one of them including an artificial blood vessel. The blood vessel was mimicking blood flow in a common carotid artery. For each experiment phantoms were heated by a therapeutic ultrasound (TU) device emitting different intensities (0.5, 1, 1.5, 1.8 W/cm2). Temperature was monitored by thermocouples and estimated through imaging ultrasound transducer's signals within specific special points inside the phantom. The temperature estimation procedure was based on temporal echo-shifts (TES), computed based on echo-shifts collected through image ultrasound (IU) transducer. Results show that TES is a reliable non-invasive method of temperature estimation, regardless the TU intensities applied. Presence of a pulsatile blood flow vessel in the focal point of TU transducer reduces thermal variation in more than 50%, also affecting the temperature variation in the surrounding area. In other words, vascularized tissues require longer ultrasound thermal therapeutic sessions or higher TU intensities and inclusion of IU in the therapeutic procedure enables non-invasive monitoring of temperature. © 2013 IEEE.
Resumo:
Evaluation of blood-flow Doppler ultrasound spectral content is currently performed on clinical diagnosis. Since mean frequency and bandwidth spectral parameters are determinants on the quantification of stenotic degree, more precise estimators than the conventional Fourier transform should be seek. This paper summarizes studies led by the author in this field, as well as the strategies used to implement the methods in real-time. Regarding stationary and nonstationary characteristics of the blood-flow signal, different models were assessed. When autoregressive and autoregressive moving average models were compared with the traditional Fourier based methods in terms of their statistical performance while estimating both spectral parameters, the Modified Covariance model was identified by the cost/benefit criterion as the estimator presenting better performance. The performance of three time-frequency distributions and the Short Time Fourier Transform was also compared. The Choi-Williams distribution proved to be more accurate than the other methods. The identified spectral estimators were developed and optimized using high performance techniques. Homogeneous and heterogeneous architectures supporting multiple instruction multiple data parallel processing were essayed. Results obtained proved that real-time implementation of the blood-flow estimators is feasible, enhancing the usage of more complex spectral models on other ultrasonic systems.
Resumo:
Dissertação de mestrado, Engenharia de Sistemas e Computação, Unidade de Ciências Exactas e Humanas, Universidade do Algarve, 1997