3 resultados para Source apportionment

em SAPIENTIA - Universidade do Algarve - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vector sensors measure both the acoustic pressure and the three components of particle velocity. Because of this, a vector sensor array (VSA) has the advantage of being able to provide substantially higher directivity with a much smaller aperture than an array of traditional scalar (pressure only) hydrophones. Although several, most of them theoretic, works were published from early nineties, only in the last years due to improvements and availability of vector sensor technology, the interest on field experiments with VSA increased in the scientific community. During the Makai Experiment, that took place off the coast of Kauai I., Hawaii, in September 2005, real data were collected with a 4 element vertical VSA. These data will be discussed in the present paper. The acoustic signals were emitted from a near source (low frequency ship noise) and two high frequency controlled acoustic sources located within a range of 2km from the VSA. The advantages of the VSA over traditional scalar hydrophone arrays in source localization will be addressed using conventional beamforming.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, an open source solution for measurement of temperature and ultrasonic signals (RF-lines) is proposed. This software is an alternative to the expensive commercial data acquisition software, enabling the user to tune applications to particular acquisition architectures. The collected ultrasonic and temperature signals were used for non-invasive temperature estimation using neural networks. The existence of precise temperature estimators is an essential point aiming at the secure and effective applica tion of thermal therapies in humans. If such estimators exist then effective controllers could be developed for the therapeutic instrumentation. In previous works the time-shift between RF-lines echoes were extracted, and used for creation of neural networks estimators. The obtained estimators successfully represent the temperature in the time-space domain, achieving a maximum absolute error inferior to the threshold value defined for hyperthermia/diathermia applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is on the implementation of a dual axis positioning system controller. The system was designed to be used for space-dependent ultrasound signal acquisition problems, such as pressure field mapping. The work developed can be grouped in two main subjects: hardware and software. Each axis includes one stepper motor connected to a driver circuit, which is then connected to a processing unit. The graphical user interface is simple and clear for the user. The system resolution was computed as 127 mu m with an accuracy of 2.44 mu m. Although the target application is ultrasound signal acquisition, the controller can be applied to other devices that has up to four stepper motors. The application was developed as an open source software, thus it can be used or changed to fit different purposes.