4 resultados para Non-Newton Flow
em SAPIENTIA - Universidade do Algarve - Portugal
Resumo:
A non-conforming three-node triangular finite element with 18 degree of freedom, is used in conjugation with the Kirchhoff theory for the non-linear analysis of thin composite plate-shell structure. The formulation of the geometrically non-linear analysis is based on an updated Lagrangian formulation associated with the Newton-Raphson iterative technique, which incorporates an automatic arc-length control procedure.
Resumo:
This paper deals with the geometrically non linear analysis of thin plate/shell laminated structures with embedded integrated piezoelectric actuors or sensors layers and/or patches.The model is based on the Kirchhoff classical laminated theory and can be applied to plate and shell adaptive structures with arbitrary shape, general mechanical and electrical loadings. the finite element model is a nonconforming single layer triangular plate/shell element with 18 degrees of fredom for the generalized displacements and one eçlectrical potential degree of freedom for each piezoelectric layer or patch. An updated Lagrangian formulation associated to Newton-Raphson technique is used to solve incrementally and iteratively the equilibrium equation.The model is applied in the solution of four illustrative cases, and the results are compared and discussedwith alternative solutions when available.
Resumo:
Aiming at time-spatial characterization of tissue temperature when ultrasound is applied for thermal therapeutic proposes two experiments were developed considering gel-based phantoms, one of them including an artificial blood vessel. The blood vessel was mimicking blood flow in a common carotid artery. For each experiment phantoms were heated by a therapeutic ultrasound (TU) device emitting different intensities (0.5, 1, 1.5, 1.8 W/cm2). Temperature was monitored by thermocouples and estimated through imaging ultrasound transducer's signals within specific special points inside the phantom. The temperature estimation procedure was based on temporal echo-shifts (TES), computed based on echo-shifts collected through image ultrasound (IU) transducer. Results show that TES is a reliable non-invasive method of temperature estimation, regardless the TU intensities applied. Presence of a pulsatile blood flow vessel in the focal point of TU transducer reduces thermal variation in more than 50%, also affecting the temperature variation in the surrounding area. In other words, vascularized tissues require longer ultrasound thermal therapeutic sessions or higher TU intensities and inclusion of IU in the therapeutic procedure enables non-invasive monitoring of temperature. © 2013 IEEE.
Resumo:
Dissertação de Mestrado, Tecnologia dos Alimentos, Instituto Superior de Engenharia, Universidade do Algarve, 2014