2 resultados para Methods: numerical

em SAPIENTIA - Universidade do Algarve - Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The morphology of a sample of four bulls and 43 cows, presumed to be descendants of the extinct cattle breed ‘Algarvia’ (AG), was used to assign their relationship with animals from other Portuguese autochthonous breeds – Arouquesa (AR), Barrosa˜ (BA), Cachena (CA), Marinhoa (MA), Maronesa (MO), Minhota (MN), Mirandesa (MI), (only bulls), Alentejana (AL), Garvonesa (GA), Mertolenga (ME) and Preta (PR). Standard numerical taxonomic methods were applied to a set of 183 (cows) and 170 (bulls) traits, to derive average pairwise taxonomic distances among the sample of 257 cows and 76 bulls. Distance coefficients (morphological index of distance) ranged from 0.22 to 2.62 (cows) and from 0.49 to 2.13 (bulls). Unweighted pair group method using arithmetic averages (UPGMA)-based phenograms and a principal coordinate analysis showed that bulls were highly clustered and cows showed a tendency to cluster according to their geographical and breed origin. The AG population grouped together with GA, AL, ME and MN breeds in the Red Convex group. The average taxonomic distance among breeds was 1.02, the highest being 1.39 (ME versus BA) and the lowest being 0.64 (MA versus AR). The approach allowed for the identification of a phenotypically differentiated set of animals, comprising 19 cows and four bulls representative of the AG breed, and which can be targeted in further studies aiming at the recovery of this extinct breed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of blood-flow Doppler ultrasound spectral content is currently performed on clinical diagnosis. Since mean frequency and bandwidth spectral parameters are determinants on the quantification of stenotic degree, more precise estimators than the conventional Fourier transform should be seek. This paper summarizes studies led by the author in this field, as well as the strategies used to implement the methods in real-time. Regarding stationary and nonstationary characteristics of the blood-flow signal, different models were assessed. When autoregressive and autoregressive moving average models were compared with the traditional Fourier based methods in terms of their statistical performance while estimating both spectral parameters, the Modified Covariance model was identified by the cost/benefit criterion as the estimator presenting better performance. The performance of three time-frequency distributions and the Short Time Fourier Transform was also compared. The Choi-Williams distribution proved to be more accurate than the other methods. The identified spectral estimators were developed and optimized using high performance techniques. Homogeneous and heterogeneous architectures supporting multiple instruction multiple data parallel processing were essayed. Results obtained proved that real-time implementation of the blood-flow estimators is feasible, enhancing the usage of more complex spectral models on other ultrasonic systems.