7 resultados para Interphase transformer
em SAPIENTIA - Universidade do Algarve - Portugal
Resumo:
This paper presents a non-invasive approach for diagnosing winding insulation failures in three-phase transformers, which is based on the on-line monitoring of the primary and secondary current Park's Vector. Experimental and simulated results demonstrate the effectiveness of the proposed technique, for detecting winding inter-turn insulation faults in operating three-phase transformers.
Resumo:
In the past few years, a considerable research effort has been devoted to the development of transformer digital models in order to simulate its behaviour under transient and abnormal operating conditions. Although many three-phase transformer models have been presented in the literature, there is a surprisingly lack of studies regarding the incorporation of winding faults. This paper presents a coupled electromagnetic transformer model for the study of winding inter-turn short-circuits. Particular attention will be given to the model parameters determination, for both healthy and faulty operating conditions. Experimental and simulation test results are presented in the paper, demonstrating the adequacy of the model as well as the methodologies for the parameters determination.
Resumo:
This paper presents the development and implementation of a digital simulation model of a threephase, three-leg, three-winding power transformer. The proposed model, implemented in MATLAB environment, is based on the simultaneous analysis of both magnetic and electric lumped-parameters equivalents circuits, and it is intended to study its adequacy to incorporate, at a later stage, the influences of the occurrence of windings interturn short-circuit faults. Both simulation and laboratory tests results, obtained so far, for a three-phase, 6 kVA transformer, demonstrate the adequacy of the model under normal operating conditions.
Resumo:
This paper presents the application of the on-load exciting current Park's Vector Approach for diagnosing permanent and intermittent turn-to-turn winding faults in operating power transformers. First, an experimental investigation of the behaviour of the transformer under the occurrence of both permanent and intermittent winding faults is presented. Finally, experimental test results demonstrate the effectiveness of the proposed diagnostic technique, which is based on the on-line monitoring of the on-load exciting current Park's Vector patterns.
Resumo:
This paper addresses the subject of condition monitoring and diagnostics of power transformers. The main results of two reliability surveys, carried out under the auspices of CIGRE and IEEE in order to assemble objective data on the performance of transformers in service, are presented, providing useful information on the main causes of transformer failures, the most likely affected components and the related outages times. A survey of the most important methods, actually in use, for condition monitoring and diagnostics of power transformers is also given, which stresses the need for the development of new diagnostic methods, that can be applied without taking the transformers out of service, and that can also provide a fault severity criteria, in particular for determining transformers windings integrity. Preliminary results, concerning the on-going research activity on the development of a new approach for inter-turn winding fault diagnosis in three-phase transformers, are also reported in the paper.
Resumo:
This paper presents the development and implementation of a digital simulation model of a three-phase, three-leg, power transformer. The proposed model, implemented in MATLAB environment, is based on the physical concept of representing windings as mutually coupled coils, and it is intended to study its adequacy to incorporate, at a later stage, the influences of the occurrence of windings inter- turn short-circuits. Both simulation and laboratory tests results, obtained so far, for a three-phase, 6 kVA transformer, demonstrate the adequacy of the model under normal operating conditions.
Resumo:
This paper addresses the subject of condition monitoring and diagnostics of power transformers. The main results of two reliability surveys, carried out under the auspices of CIGRE and IEEE in order to assemble objective data on the performance of transformers in service, are presented, providing useful information on the main causes of transformer failures, the most likely affected components and the related outages times. A survey of the most important methods, actually in use, for condition monitoring and diagnostics of power transformers is also given, which stresses the need for the development of new diagnostic methods, that can be applied without taking the transformers out of service, and that can also provide a fault severity criteria, in particular for determining transformers windings integrity. Preliminary results, concerning the on-going research activity on the development of a new approach for inter-turn winding fault diagnosis in three-phase transformers, are also reported in the paper.