3 resultados para Conventional techniques

em SAPIENTIA - Universidade do Algarve - Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de Mestrado, Gestão da Água e da Costa, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2007

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Field effect transistors (FETs) based on organic materials were investigated as sensors for detecting 2,4,6-trinitrotoluene (TNT) vapors. Several FET devices were fabricated using two types of semiconducting organic materials, solution processed polymers deposited by spin coating and, oligomers (or small molecules) deposited by vacuum sublimation. When vapors of nitroaromatic compounds bind to thin films of organic materials which form the transistor channel, the conductivity of the thin film increases and changes the transistor electrical characteristic. The use of the amplifying properties of the transistor represents a major advantage over conventional techniques based on simple changes of resistance in polymers frequently used in electronic noses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of blood-flow Doppler ultrasound spectral content is currently performed on clinical diagnosis. Since mean frequency and bandwidth spectral parameters are determinants on the quantification of stenotic degree, more precise estimators than the conventional Fourier transform should be seek. This paper summarizes studies led by the author in this field, as well as the strategies used to implement the methods in real-time. Regarding stationary and nonstationary characteristics of the blood-flow signal, different models were assessed. When autoregressive and autoregressive moving average models were compared with the traditional Fourier based methods in terms of their statistical performance while estimating both spectral parameters, the Modified Covariance model was identified by the cost/benefit criterion as the estimator presenting better performance. The performance of three time-frequency distributions and the Short Time Fourier Transform was also compared. The Choi-Williams distribution proved to be more accurate than the other methods. The identified spectral estimators were developed and optimized using high performance techniques. Homogeneous and heterogeneous architectures supporting multiple instruction multiple data parallel processing were essayed. Results obtained proved that real-time implementation of the blood-flow estimators is feasible, enhancing the usage of more complex spectral models on other ultrasonic systems.