3 resultados para performance assessment
em Research Open Access Repository of the University of East London.
Resumo:
An in situ experiment on a full-scale timber frame test building was carried out to study the hygrothermal performance of wood-hemp composite insulation in timber frame wall panels with and without a vapour barrier. The heat transfer properties and the likelihood of mould growth and condensation in the panels were compared. Step changes in the internal relative humidity were performed to explore the effects of high, normal and low internal moisture loads on the wall panels. No significant difference in the average equivalent thermal transmittance (U-values) between the panels with and without a vapour barrier was observed. The average equivalent U-values of the panels were close to the U-values calculated from the manufacturers’ declared thermal conductivity values of the insulation. The likelihood of condensation was higher at the interface of the wood-hemp insulation and the oriented strand board (OSB) in the panel without a vapour barrier. In terms of the parametric assessment of the mould germination potential, the relative humidity, the temperature and the exposure conditions in the insulation-OSB interfaces of the panel without a vapour barrier were found to be more favourable to the germination of mould spores. Nonetheless, when the insulations were dismantled, no mould was visually detected.
Resumo:
An in situ experiment in a full scale timber frame test building was carried out to compare the hygrothermal performance of Hemp and Stone Wool insulations of identical thermal conductivity. Hemp and Stone Wool insulations were installed in timber frame wall panels without vapour barrier. The comparison was made in terms of heat transfer properties, likelihood of mould growth and condensation. Step changes in internal relative humidity were performed to explore the effect of high and normal internal moisture load on the wall panels. No significant difference between the average equivalent thermal transmittance (U-values) of the panels incorporating Hemp and Stone Wool insulations was observed. The average equivalent U-values of the panels were closer to the calculated U-values of the panels based on the manufacturers’ declared thermal conductivity of Hemp and Stone Wool insulations. It was observed that the placement of heat flux sensor along the depth of the insulation had significant influence on the measured equivalent U-value of the panels during high internal moisture load. The frequency and likelihood of condensation was higher in the interface of Stone Wool and Oriented Strand Board (OSB). In terms of the parametric assessment of mould germination potential, relative humidity, temperature and exposure conditions in the insulation-OSB interfaces were found to be favourable to germination of mould spore. However, when the insulations were dismantled, no mould was visually detected.
Resumo:
In a previous exploratory study we observed no relevant differences in psychopathology, personality, and functioning between inpatients diagnosed with gastrointestinal motor disorders (GMDs) or functional gastrointestinal disorders (FGDs) [1]. However, we observed higher levels of incongruence between clinician-assessed performance status and patients’ self-reported levels of functioning among patients diagnosed with FGDs. Likewise, research in other medical conditions has shown incongruences between self-reported and clinician-reported or objective measures [2]. Furthermore, in a study on chronic depression, the authors found that discrepancies between patients’ and physicians’ assessments of medical comorbidities were related to higher levels of depressive symptomatology [3]. In this line, the aim of this study was to explore whether the inconsistencies between clinician-assessed and patient self-reported levels of functioning could be related to psychopathology among patients admitted for evaluation of gastrointestinal motility.