4 resultados para Optimizations of concrete traces

em Research Open Access Repository of the University of East London.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the experimental work carried out on a full scale concrete frame strengthened with Fibre Reinforced Polymer (FRP) composites. The frame was damaged, strengthened with FRP reinforcement and re-tested to assess the effectiveness of the strengthening technique. The natural frequencies of vibration, displacements, velocities and accelerations for both the unstrengthened and strengthened frame were recorded and compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an experimental investigation carried out on concrete cylinders confined with fibre reinforced polymers (FRP), subjected to monotonic and cyclic loading. Carbon fibres (CFRP) were used as confining material for the concrete specimens. The failure mode, reinforcement ratio based on jacket thickness and type of loading are examined. The study shows that external confinement of concrete can enhance its strength and ductility as well as result in large energy absorption capacity. This has important safety implications, especially in regions with seismic activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an experimental investigation carried out on concrete filled fibre reinforced polymers (FRP) tubes, subjected to monotonic and cyclic loading. Two types of FRP materials were used: glass fibres and carbon fibres. Different failure modes and the effect of concrete fill, type of confinement materials, reinforcement ratio based on tube thickness and type of loading are examined. The study shows that external confinement of concrete by means of modern materials, such fibre reinforced polymers, can enhance its strength and ductility as well as result in large energy absorption capacity. This has important safety implications, especially in regions with seismic activity. A model that predicts the behaviour of confined concrete which takes into account the stiffness and effectiveness of different confinement materials is briefly introduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

On March 11 2011, an exceptionally large tsunami event was triggered by a massive earthquake offshore, the northeast coast of Japan, which affected coastal infrastructure such as seawalls, coastal dikes and breakwaters in the Tohoku region. Such infrastructure was built to protect against the Level 1 tsunamis that previously hit the region, but not for events as significant as the 2011 Tohoku tsunami, which was categorized as a Level 2 tsunami [Shibayama et al. 2013]. The failure mechanisms of concrete-armoured dikes, breakwaters and seawalls due to Level 2 tsunamis are still not fully understood by researchers and engineers. This paper investigates the failure modes and mechanisms of damaged coastal structures in Miyagi and Fukushima Prefectures, following the authors' post-disaster field surveys carried out between 2011 and 2013. Six significant failure mechanisms were identified for the coastal dikes and seawalls affected by this tsunami: 1) Leeward toe scour failure, 2) Crown armour failure, 3) Leeward slope armour failure, 4) Seaward toe and armour failure, 5) Overturning failure, and 6) Parapet wall failure, in which leeward toe scour being recognized as the major failure mechanism in most surveyed locations. The authors also propose a simple practical mathematical model for predicting the scour depth at the leeward toe of the coastal dikes, by considering the effects of the tsunami hydrodynamics, the soil properties and the type of structure. The key advantage of this model is that it depends entirely on quantities that are measurable in the field. Furthermore this model was further refined by conducting a series of hydraulic model experiments aimed to understand the governing factors of the leeward toe scour failure. Finally, based on the results obtained, key recommendations are given for the design of resilient coastal defence structures that can survive a level 2 tsunami event.