3 resultados para Numerical power performance

em Research Open Access Repository of the University of East London.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This investigation aimed to explore the effects of inert sugar-free drinks described as either ‘performance enhancing’ (placebo) or ‘fatigue inducing’ (nocebo) on peak minute power (PMP;W) during incremental arm crank ergometry (ACE). Twelve healthy, non-specifically trained individuals volunteered to take part. A single-blind randomised controlled trial with repeated measures was used to assess for differences in PMP;W, oxygen uptake, heart rate (HR), minute ventilation, respiratory exchange ratio (RER) and subjective reports of local ratings of perceived exertion (LRPE) and central ratings of perceived exertion (CRPE), between three separate, but identical ACE tests. Participants were required to drink either 500 ml of a ‘sports performance’ drink (placebo), a ‘fatigue-inducing’ drink (nocebo) or water prior to exercise. The placebo caused a significant increase in PMP;W, and a significant decrease in LRPE compared to the nocebo (p=0.01; p=0.001) and water trials (p=0.01). No significant differences in PMP;W between the nocebo and water were found. However, the nocebo drink did cause a significant increase in LRPE (p=0.01). These results suggest that the time has come to broaden our understanding of the placebo and nocebo effects and their potential to impact sports performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to examine the effect of carbohydrate mouth rinse on 30-min arm cranking performance. Twelve healthy, active males (age 21.6, standard deviation (SD)=3.1 years; mass 76.2, SD=12.2 kg) volunteered in a single-blind, randomised crossover design. Firstly they completed an incremental exercise test to exhaustion (VO2max test) on an arm crank (50W for 2 min, increasing by 10W every min). During visit 2 and 3 they arm cranked for maximal distance over 30 min at a resistance equivalent to 50% of their peak power, mouth rinsing for 5 s with either 25 ml of a tasteless 6.4% maltodextrin solution (CHO) or 25 ml of water (placebo) every 6 min. A letter cancellation test was performed pre and post exercise to measure cognitive function. The result showed that cognitive function was not significantly different between trials (P=0.874). There was no significant difference in distance arm cranked between trials (P=0.164) even though 9 out of 12 participants had improved performance on the CHO trial. In conclusion, further research is needed to determine the ergogenic effect of CHO mouth rinsing on upper body exercise performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This investigation aimed to explore the effects of inert sugar-free drinks described as either ‘performance enhancing’ (placebo) or ‘fatigue inducing’ (nocebo) on peak minute power (PMP;W) during incremental arm crank ergometry (ACE). Twelve healthy, non-specifically trained individuals volunteered to take part. A single-blind randomised controlled trial with repeated measures was used to assess for differences in PMP;W, oxygen uptake, heart rate (HR), minute ventilation, respiratory exchange ratio (RER) and subjective reports of local ratings of perceived exertion (LRPE) and central ratings of perceived exertion (CRPE), between three separate, but identical ACE tests. Participants were required to drink either 500 ml of a ‘sports performance’ drink (placebo), a ‘fatigue-inducing’ drink (nocebo) or water prior to exercise. The placebo caused a significant increase in PMP;W, and a significant decrease in LRPE compared to the nocebo (p=0.01; p=0.001) and water trials (p=0.01). No significant differences in PMP;W between the nocebo and water were found. However, the nocebo drink did cause a significant increase in LRPE (p=0.01). These results suggest that the time has come to broaden our understanding of the placebo and nocebo effects and their potential to impact sports performance.