2 resultados para Migraine without aura
em Research Open Access Repository of the University of East London.
Resumo:
Participants who were unable to detect familiarity from masked 17 ms faces ([Stone and Valentine, 2004] and [Stone and Valentine, in press-b]) did report a vague, partial visual percept. Two experiments investigated the relative strength of the visual percept generated by famous and unfamiliar faces, using masked 17 ms exposure. Each trial presented simultaneously a famous and an unfamiliar face, one face in LVF and the other in RVF. In one task, participants responded according to which of the faces generated the stronger visual percept, and in the other task, they attempted an explicit familiarity decision. The relative strength of the visual percept of the famous face compared to the unfamiliar face was moderated by response latency and participants’ attitude towards the famous person. There was also an interaction of visual field with response latency, suggesting that the right hemisphere can generate a visual percept differentiating famous from unfamiliar faces more rapidly than the left hemisphere. Participants were at chance in the explicit familiarity decision, confirming the absence of awareness of facial familiarity.
Resumo:
An in situ experiment on a full-scale timber frame test building was carried out to study the hygrothermal performance of wood-hemp composite insulation in timber frame wall panels with and without a vapour barrier. The heat transfer properties and the likelihood of mould growth and condensation in the panels were compared. Step changes in the internal relative humidity were performed to explore the effects of high, normal and low internal moisture loads on the wall panels. No significant difference in the average equivalent thermal transmittance (U-values) between the panels with and without a vapour barrier was observed. The average equivalent U-values of the panels were close to the U-values calculated from the manufacturers’ declared thermal conductivity values of the insulation. The likelihood of condensation was higher at the interface of the wood-hemp insulation and the oriented strand board (OSB) in the panel without a vapour barrier. In terms of the parametric assessment of the mould germination potential, the relative humidity, the temperature and the exposure conditions in the insulation-OSB interfaces of the panel without a vapour barrier were found to be more favourable to the germination of mould spores. Nonetheless, when the insulations were dismantled, no mould was visually detected.