3 resultados para micro CT
em Repositório Institucional da Universidade de Aveiro - Portugal
Resumo:
Coronary CT angiography is widely used in clinical practice for the assessment of coronary artery disease. Several studies have shown that the same exam can also be used to assess left ventricle (LV) function. LV function is usually evaluated using just the data from end-systolic and end-diastolic phases even though coronary CT angiography (CTA) provides data concerning multiple cardiac phases, along the cardiac cycle. This unused wealth of data, mostly due to its complexity and the lack of proper tools, has still to be explored in order to assess if further insight is possible regarding regional LV functional analysis. Furthermore, different parameters can be computed to characterize LV function and while some are well known by clinicians others still need to be evaluated concerning their value in clinical scenarios. The work presented in this thesis covers two steps towards extended use of CTA data: LV segmentation and functional analysis. A new semi-automatic segmentation method is presented to obtain LV data for all cardiac phases available in a CTA exam and a 3D editing tool was designed to allow users to fine tune the segmentations. Regarding segmentation evaluation, a methodology is proposed in order to help choose the similarity metrics to be used to compare segmentations. This methodology allows the detection of redundant measures that can be discarded. The evaluation was performed with the help of three experienced radiographers yielding low intraand inter-observer variability. In order to allow exploring the segmented data, several parameters characterizing global and regional LV function are computed for the available cardiac phases. The data thus obtained is shown using a set of visualizations allowing synchronized visual exploration. The main purpose is to provide means for clinicians to explore the data and gather insight over their meaning, as well as their correlation with each other and with diagnosis outcomes. Finally, an interactive method is proposed to help clinicians assess myocardial perfusion by providing automatic assignment of lesions, detected by clinicians, to a myocardial segment. This new approach has obtained positive feedback from clinicians and is not only an improvement over their current assessment method but also an important first step towards systematic validation of automatic myocardial perfusion assessment measures.
Resumo:
In the present work multilayered micro/nanocrystalline (MCD/NCD) diamond coatings were developed by Hot Filament Chemical Vapour Deposition (HFCVD). The aim was to minimize the surface roughness with a top NCD layer, to maximize adhesion onto the Si3N4 ceramic substrates with a starting MCD coating and to improve the mechanical resistance by the presence of MCD/NCD interfaces in these composite coatings. This set of features assures high wear resistance and low friction coefficients which, combined to diamond biocompatibility, set this material as ideal for biotribological applications. The deposition parameters of MCD were optimized using the Taguchi method, and two varieties of NCD were used: NCD-1, grown in a methane rich gas phase, and NCD-2 where a third gas, Argon, was added to the gas mixture. The best combination of surface pre-treatments in the Si3N4 substrates is obtained by polishing the substrates with a 15 μm diamond slurry, further dry etching with CF4 plasma for 10 minutes and final ultrasonic seeding in a diamond powder suspension in ethanol for 1 hour. The interfaces of the multilayered CVD diamond films were characterized with high detail using HRTEM, STEM-EDX and EELS. The results show that at the transition from MCD to NCD a thin precursor graphitic film is formed. On the contrary, the transition of the NCD to MCD grade is free of carbon structures other than diamond, as a result of the richer atomic hydrogen content and of the higher substrate temperature for MCD deposition. At those transitions, WC nanoparticles were found due to contamination from the filament, being also present at the first interface of the MCD layer with the silicon nitride substrate. In order to study the adhesion and mechanical resistance of the diamond coatings, indentation and particle jet blasting tests were conducted, as well as tribological experiments with homologous pairs. Indentation tests proved the superior behaviour of the multilayered coatings that attained a load of 800 N without delamination, when compared to the mono and bilayered ones. The multilayered diamond coatings also reveal the best solid particle erosion resistance, due to the MCD/NCD interfaces that act as crack deflectors. These results were confirmed by an analytical model on the stress field distribution based on the von Mises criterion. Regarding the tribological testing under dry sliding, multilayered coatings also exhibit the highest critical load values (200N for Multilayers with NCD-2). Low friction coefficient values in the range μ=0.02- 0.09 and wear coefficient values in the order of ~10-7 mm3 N-1 m-1 were obtained for the ball and flat specimens indicating a mild wear regime. Under lubrication with physiological fluids (HBSS e FBS), lower wear coefficient values ~10-9-10-8 mm3 N-1 m-1) were achieved, governed by the initial surface roughness and the effective contact pressure.
Resumo:
This work reports one possible way to develop new functional coatings used to increase the life time of metallic structures. The functionalities selected and attributed to model coatings in the frame of this work were corrosion protection, self-sensing and prevention of fouling (antifouling). The way used to confer those functionalities to coatings was based on the encapsulation of active compounds (corrosion inhibitors, pH indicators and biocides) in micro and nanocontainers followed by their incorporation into the coating matrices. To confer active corrosion protection, one corrosion inhibitor (2-mercaptobenzothiazole, MBT) was encapsulated in two different containers, firstly in silica nanocapsules (SiNC) and in polyurea microcapsules (PU-MC). The incorporation of both containers in different models coatings shows a significant improvement in the corrosion protection of aluminum alloy 2024 (AA2024). Following the same approach, SiNC and PU-MC were also used for the encapsulation of phenolphthalein (one well known pH indicator) to introduce sensing properties in polymeric coatings. SiNC and PU-MC containing phenolphthalein acted as corrosion sensor, showing a pink coloration due to the beginning of cathodic reaction, resulting in a pH increase identified by those capsules. Their sensing performance was proved in suspension and when integrated in coatings for aluminium alloy 2024 and magnesium alloy AZ31. In a similar way, the biocide activity (antifouling) was assigned to two polymeric matrices using SiNC for encapsulation of one biocide (Dichloro-2-octyl-2H-isothiazol-3-one, DCOIT) and also SiNC-MBT was tested as biocide. The antifouling activity of those two encapsulated compounds was assessed through inhibition and consequent decrease in the bioluminescence of modified E. coli. That effect was verified in suspension and when incorporated in coatings for AISI 1008 carbon steel. The developed micro and nanocontainers presented the desired performance, allowing the introduction of new functionalities to model coatings, showing potential to be used as functional additives in the next generation of multifunctional coatings.