2 resultados para Vermont and Canada Railroad Co.

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses the advantages of using a combined environmagnetic and geochemical approach to the provenance and characterization of distal IRDs occurring during the Last Glacial Period in core CI12PC3 from the Galicia Interior Basin (GIB). Six Heinrich layers (HL1-6) have been identified in the area in base to the detection of distinct populations of exotic magnetic mineral assemblages alien to the local/regional sedimentation environment. Their extension has been determined by Ca/Sr and Si/Sr ratios and their provenance by 143Nd/144Nd and 87Sr/86Sr isotopic ratios and FORCs. The sedimentary expression of HL is characterized by the presence of distal Ice Rafted Detritus (IRD). Distal IRD magnetic signatures in the GIB consist of (i) an increase of one order of magnitude in the peak amplitude of magnetic susceptibility from background values, (ii) a general coarsening of the magnetic grain size in a mineral assemblage dominated by titano-magnetites, (iii) FORC distributions pushing towards the coarse MD or PSD component, and (iv) thermomagnetic curves depicting the occurrence of several magnetite phases. These four features are very different from the fine-grained biogenic magnetic assemblages characterized by the combination of lower MS and higher coercivity values that dominate the predominant mixtures of the non-interacting SSD and PSD components in the non-IRD influenced background sedimentation. Our results show that the last 70.000 yr of sedimentation in the GIB were controlled by the relative contribution of local detrital material derived from the Iberian Variscan Chain and IRD alien material from the iceberg melting during the Heinrich Events. They also show two main IRD provenance fields: Europe and Canada. And that the later is more important for for HL1, HL2, HL4 and HL5. FORCs analysis complemented the isotopic information and provided a very unique information, indicating that glacial flour may not always have the same provenance as IRD and that ice-melted derived suspended sediment has its own dynamics and may reach further and/or persists longer than IRD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: For the diagnosis of frailty exhaustion is a criteria currently measured by self-reported questionnaires, which are subjective and dependent on individual perception. The FR test has been developed as a bed side objective evaluation of muscle fatigue. The test was validated for the VM. However, the JD is frequently used to measure the grip strength. So the comparison of these devices is required to understand if FR is similar when measured with both devices. Methods: Fifty-four (29 female and 25 male; mean age: 39.98 ± 18.09) community-dwelling people were tested for muscle function. The Fatigue resistance (FR), which is the time during that grip strength drops to 50% of its maximum, was recorded with each device and simultaneous sEMG of the forearm muscles was obtained. The (co-)activation of agonist and antagonist muscles was calculated and compared with the differences between the performances with each device (controlling for gender and age). Results: FR was significantly better when measured with VM compared to JD. At all phases of the FR-test the antagonist muscle co-activation was significantly higher for VM compared to JD. In contrast, the agonist muscle activation level was significantly higher in JD compared to VM. When performing the FR-test with VM, both the agonist muscle activation and antagonist muscle co-activation decreased significantly (p<0.05). Whereas when using the JD, only a significant decrease in the antagonist muscle co-activation was observed. The difference in antagonist muscle activation between VM and JD was significantly related to the difference in FR between both devices. Conclusion: The results suggest that the FR-test when using the VM induces a more prominent muscle exhaustion than when using the JD, which makes the VM more suitable for measuring muscle fatigue resistance. However, these findings must be confirmed in a larger study population.