6 resultados para Signalto Noise Ratio (SNR)

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flexible radio transmitters based on the Software-Defined Radio (SDR) concept are gaining an increased research importance due to the unparalleled proliferation of new wireless standards operating at different frequencies, using dissimilar coding and modulation schemes, and targeted for different ends. In this new wireless communications paradigm, the physical layer of the radio transmitter must be able to support the simultaneous transmission of multi-band, multi-rate, multi-standard signals, which in practice is very hard or very inefficient to implement using conventional approaches. Nevertheless, the last developments in this field include novel all-digital transmitter architectures where the radio datapath is digital from the baseband up to the RF stage. Such concept has inherent high flexibility and poses an important step towards the development of SDR-based transmitters. However, the truth is that implementing such radio for a real world communications scenario is a challenging task, where a few key limitations are still preventing a wider adoption of this concept. This thesis aims exactly to address some of these limitations by proposing and implementing innovative all-digital transmitter architectures with inherent higher flexibility and integration, and where improving important figures of merit, such as coding efficiency, signal-to-noise ratio, usable bandwidth and in-band and out-of-band noise will also be addressed. In the first part of this thesis, the concept of transmitting RF data using an entirely digital approach based on pulsed modulation is introduced. A comparison between several implementation technologies is also presented, allowing to state that FPGAs provide an interesting compromise between performance, power efficiency and flexibility, thus making them an interesting choice as an enabling technology for pulse-based all-digital transmitters. Following this discussion, the fundamental concepts inherent to pulsed modulators, its key advantages, main limitations and typical enhancements suitable for all-digital transmitters are also presented. The recent advances regarding the two most common classes of pulse modulated transmitters, namely the RF and the baseband-level are introduced, along with several examples of state-of-the-art architectures found on the literature. The core of this dissertation containing the main developments achieved during this PhD work is then presented and discussed. The first key contribution to the state-of-the-art presented here consists in the development of a novel ΣΔ-based all-digital transmitter architecture capable of multiband and multi-standard data transmission in a very flexible and integrated way, where the pulsed RF output operating in the microwave frequency range is generated inside a single FPGA device. A fundamental contribution regarding the simultaneous transmission of multiple RF signals is then introduced by presenting and describing novel all-digital transmitter architectures that take advantage of multi-gigabit data serializers available on current high-end FPGAs in order to transmit in a time-interleaved approach multiple independent RF carriers. Further improvements in this design approach allowed to provide a two-stage up-conversion transmitter architecture enabling the fine frequency tuning of concurrent multichannel multi-standard signals. Finally, further improvements regarding two key limitations inherent to current all-digital transmitter approaches are then addressed, namely the poor coding efficiency and the combined high quality factor and tunability requirements of the RF output filter. The followed design approach based on poliphase multipath circuits allowed to create a new FPGA-embedded agile transmitter architecture that significantly improves important figures of merit, such as coding efficiency and SNR, while maintains the high flexibility that is required for supporting multichannel multimode data transmission.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

No trabalho apresentado realiza-se uma primeira descrição de voz e emoção para o Português Europeu. Estudamos, utilizando como base estudos realizados em diversas línguas (finlandês; inglês; alemão), os parâmetros relacionados com voz e que variam consoante a emoção que expressamos. Analisamos assim os parâmetros relacionados com a frequência Fundamental (F0) com a perturbação (jitter) com a amplitude (shimmer) e com aspectos relacionados com o ruído (HNR). Trata-se de um estudo abrangente que estudando voz e a sua relação/variação de acordo com a emoção o faz em três vertentes: patologia de voz de origem psicogénica (carácter emocional); emoção produzida por actores e a análise de emoção espontânea. Conseguindo, como trabalho pioneiro nesta área, valores para todos estes tipos de produção. Salientamos o facto de no nosso trabalho apenas existir a análise de voz sem recurso a expressão facial ou à postura dos indivíduos. Para que pudéssemos realizar estudos comparativos com os dados que íamos recolhendo em cada corpus (patologia; emoção por actor e emoção espontânea), procurámos utilizar sempre os mesmos métodos de análise (Praat; SFS; SPSS, Hoarseness Diagram – para a análise de voz com patologia - e o sistema Feeltrace - para as emoções espontâneas). Os estudos e análises relativos à emoção produzida por actores são complementados por testes de percepção aplicados a falantes nativos de Inglês Americano e a falantes de Português Europeu. Este teste, juntamente com a análise da emoção espontânea, permitiu-nos retirar dados particulares relativos à língua portuguesa. Apesar de haver tanto na expressão como na percepção de emoções muitas características consideradas universais, em Português percebe-se algo de peculiar. Os valores para a expressão neutra; tristeza e alegria são todos muito próximos, ao contrário do que acontece noutras línguas. Além disso estas três emoções (de famílias distintas) são as que mais dificuldades causam (aos dois grupos de informantes) em termos de distinção no teste de percepção. Poderá ser esta a particularidade da expressão da emoção no Português Europeu, podendo estar ligada a factores culturais. Percebe-se ainda, com este trabalho, que a emoção expressa pelo actor se aproxima da emoção espontânea. No entanto, alguns parâmetros apresentam valores diferentes, isto porque o actor tem a tendência de exagerar a emoção. Com este trabalho foram criados corpora originais que serão um recurso importante a disponibilizar para futuras análises numa área que é ainda deficitária, em termos de investigação científica, em Portugal. Tanto os corpora, como respectivos resultados obtidos poderão vir a ser úteis em áreas como as Ciências da Fala; Robótica e Docência.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work several techniques to monitor the performance of optical networks were developed. These techniques are dedicated either to the measurement of the data signal parameters (optical signal to noise ratio and dispersion) or to the detection of physical failures on the network infrastructure. The optical signal to noise ratio of the transmitted signal was successfully monitored using methods based on the presence of Bragg gratings imprinted on high birefringent fibres that allowed the distinction of the signal from the noise due to its polarization properties. The monitoring of the signal group-velocity dispersion was also possible. In this case, a method based on the analysis of the electric spectrum of the signal was applied. It was experimentally demonstrated that this technique is applicable on both amplitude and phase modulated signals. It was also developed a technique to monitor the physical infrastructure of an optical access network. Once again, the application of Bragg gratings (this time imprinted on standard single mode fibres) was the basis of the developed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of computed tomography systems with energy resolving detectors is a current challenge in medical physics and biomedical engineering. A computed tomography system of this kind allows getting complementary informations relatively to conventional systems, that can help the medical diagnosis, being of great interest in medicine. The work described in this thesis is related to the development of a computed tomography system using micropattern gaseous detectors, which allow storing, simultaneously, information about the interaction position and the energy of each single photon that interacts with the detector. This kind of detectors has other advantages concerning the cost and characteristics of operation when compared with solid state detectors. Tomographic acquisitions were performed using a MicroHole & Strip Plate based detector, which allowed reconstructing cross-sectional images using energy windows, applying the energy weighting technique and performing multi-slice and tri-dimensional reconstructions. The contrast-to-noise ratio was improved by 31% by applying the energy weighting technique, comparing with the corresponding image obtained with the current medical systems. A prototype of a computed tomography with flexibility to change the detector was developed, making it possible to apply different detectors based on Thick-COBRA. Several images acquired with these detectors are presented and demonstrate their applicability in X-ray imaging. When operating in NeCH4, the detector allowed a charge gain of 8 104, an energy resolution of 20% (full width at half maximum at 8 keV), a count rate of 1 106 Hz/mm2, a very stable operation (gain fluctuations below 5%) and a spacial resolution of 1.2 mm for an energy photon of 3.6 keV. Operating the detector in pure Kr allowed increasing the detection efficiency and achieving a charge gain of 2 104, an energy resolution of 32% (full width at half maximum at 22 keV), a count rate of 1 105 Hz/mm2, very stable operation and a spatial resolution of 500 m. The software already existing in the group was improved and tools to correct geometric misalignments of the system were also developed. The reconstructions obtained after geometrical correction are free of artefacts due to the referred misalignments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho teve como objetivos a produção, caracterização e aplicação de microelétrodos (MEs) de diamante como sensores amperométricos e potenciométricos em sistemas de corrosão nos quais a agressividade do meio e a presença de produtos de corrosão, constituem obstáculos que podem diminuir o desempenho, ou inviabilizar a utilização, de outros tipos de sensores. Os microeléctrodos são baseados em filmes finos de diamante dopado com boro (BDD – Boron Doped Diamond) depositados sobre fios de tungsténio afiados, através do método de deposição química a partir da fase vapor, assistida por filamento quente (HFCVD – Hot Filament Chemical Vapor Deposition). A otimização das diversas etapas de fabricação dos MEs deu origem ao desenvolvimento de um novo sistema de afiamento eletroquímico para obtenção destes fios e a várias opções para a obtenção dos filmes de diamante condutor e seu isolamento com resinas para exposição apenas da ponta cilíndrica. A qualidade cristalina dos filmes de diamante foi avaliada por espectroscopia de Raman. Esta informação foi complementada com uma caracterização microestrutural dos filmes de diamante por microscopia eletrónica de varrimento (SEM), em que se fez a identificação da tipologia dos cristais como pertencendo às gamas de diamante nanocristalino ou microcristalino. Os filmes de BDD foram utilizados na sua forma não modificada, com terminações em hidrogénio e também com modificação da superfície através de tratamentos de plasma RF de CF4 e O2 indutores de terminações C-F no primeiro caso e de grupos C=O, C-O-C e C-OH no segundo, tal como determinado por XPS. A caracterização eletroquímica dos MEs não modificados revelou uma resposta voltamétrica com elevada razão sinal/ruído e baixa corrente capacitiva, numa gama de polarização quasi-ideal com extensão de 3 V a 4 V, dependente dos parâmetros de crescimento e pós-tratamentos de superfície. Estudou-se a reversibilidade de algumas reações heterogéneas com os pares redox Fe(CN)6 3-/4- e FcOH0/+ e verificou-se que a constante cinética, k0, é mais elevada em elétrodos com terminações em hidrogénio, nos quais não se procedeu a qualquer modificação da superfície. Estes MEs não modificados foram também testados na deteção de Zn2+ onde se observou, por voltametria cíclica, que a detecção da redução deste ião é linear numa escala log-log na gama de 10-5-10-2 M em 5 mM NaCl. Realizaram-se também estudos em sistemas de corrosão modelares, em que os microeléctrodos foram usados como sensores amperométricos para mapear a distribuição de oxigénio e Zn2+ sobre um par galvânico Zn-Fe, com recurso a um sistema SVET (Scanning Vibrating Electrode Technique). Foi possível detetar, com resolução lateral de 100 μm, um decréscimo da concentração de O2 junto a ambos os metais e produção de catiões de zinco no ânodo. Contudo verificou-se uma significativa deposição de zinco metálico na superfície dos ME utilizados. Os MEs com superfície modificada por plasma de CF4 foram testados como sensores de oxigénio dissolvido. A calibração dos microeléctrodos foi efetuada simultaneamente por voltametria cíclica e medição óptica através de um sensor de oxigénio comercial. Determinou-se uma sensibilidade de ~0.1422 nA/μM, com um limite de deteção de 0.63 μM. Os MEs modificados com CF4 foram também testados como sensores amperométricos com os quais se observou sensibilidade ao oxigénio dissolvido em solução, tendo sido igualmente utilizados durante a corrosão galvânica de pares Zn-Fe. Em alguns casos foi conseguida sensibilidade ao ião Zn2+ sem que o efeito da contaminação superficial com zinco metálico se fizesse sentir. Os microeléctrodos tratados em plasma de CF4 permitem uma boa deteção da distribuição de oxigénio, exibindo uma resposta mais rápida que os não tratados além de maior estabilidade de medição e durabilidade. Nos MEs em que a superfície foi modificada com plasma de O2 foi possível detetar, por cronopotenciometria a corrente nula, uma sensibilidade ao pH de ~51 mV/pH numa gama de pH 2 a pH 12. Este comportamento foi associado à contribuição determinante de grupos C-O e C=O, observados por XPS com uma razão O/C de 0,16. Estes MEs foram igualmente testados durante a corrosão galvânica do par Zn-Fe onde foi possível mapear a distribuição de pH associada ao desenvolvimento de regiões alcalinas causadas pela redução do oxigénio, acima da região catódica, e de regiões ácidas decorrentes da dissolução anódica do ânodo de zinco. Com o par galvânico imerso em 50 mM NaCl registou-se uma variação de pH aproximadamente entre 4,8 acima do ânodo de zinco a 9,3 sobre o cátodo de ferro. A utilização pioneira destes MEs como sensores de pH é uma alternativa promissora aos elétrodos baseados em membranas seletivas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente estudo tem como objetivo a caraterização acústica da voz normal para os falantes do Português Europeu, em termos de frequência fundamental, jitter, shimmer e relação sinal-ruído. São também analisadas as caraterísticas individuais que possam ter influência sobre a qualidade vocal, nomeadamente idade, género, índice de massa corporal, hábitos tabágicos e uso da voz no canto. Para tal, foram recolhidas amostras de fala de 363 indivíduos com uma voz avaliada como normal: 113 homens e 250 mulheres com idades compreendidas entre os 18 e os 91 anos. Amostras da produção sustentada da vogal /a/ foram analisadas acusticamente com o programa Praat, tendo sido extraídos os valores da média, mediana e desvio-padrão da frequência fundamental, jitter (ppq5), shimmer (apq11) e relação sinal-ruído. Os resultados obtidos apontam no sentido do género e a idade do indivíduo serem os fatores que maior influência exercem na voz, sendo que ambos os géneros apresentam um declínio da qualidade vocal ao longo da vida. As mulheres, globalmente, apresentam valores de frequência fundamental de 193,4±28,5 Hz (média ± desvio padrão da média), significativamente mais elevados que os homens, com valores de 120,7±22,3 Hz. Em termos de jitter, as mulheres obtiveram valores de 0,214±0,126 %, significativamente mais reduzidos que os 0,247±0,190 % obtidos para os homens. O shimmer não apresentou diferenças significativas entre géneros, sendo que os valores apresentados foram de 5,403±2,652 % para homens e 5,174±2,696 % para as mulheres. Relativamente à relação sinal-ruído, foram obtidos valores significativamente mais elevados nas mulheres, com 17,335±3,958 dB, tendo-se obtido para os homens 16,315±3,267 dB. Não foi encontrado um efeito significativo do índice de massa corporal, hábitos tabágicos e uso da voz no canto. Este trabalho disponibiliza novos dados para que a avaliação da voz em contexto clínico seja mais objetiva e eficaz.