3 resultados para Infrared and Raman spectroscopy

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last decades, the effects of the air pollution have been increasing, especially in the case of the human health diseases. In order to overcome this problem, scientists have been studying the components of the air. As a part of water-soluble organic compounds, amino acids are present in the atmospheric environment as components of diverse living organisms which can be responsible for spreading diseases through the air. Liquid chromatography is one technique capable of distinguish the different amino acids from each other. In this work, aiming at separating the amino acids found in the aerosols samples collected in Aveiro, the ability of four columns (Mixed-Mode WAX-1, Mixed-Mode HILIC-1, Luna HILIC and Luna C18) to separate four amino acids (aspartic acid, lysine, glycine and tryptophan) and the way the interaction of the stationary phases of the columns with the analytes is influenced by organic solvent concentration and presence/concentration of the buffer, are being assessed. In the Mixed-Mode WAX-1 column, the chromatograms of the distinct amino acids revealed the separation was not efficient, since the retention times were very similar. In the case of lysine, in the elution with 80% (V/V) MeOH, the peaks appeared during the volume void. In the Mixed-Mode HILIC-1 column, the variation of the organic solvent concentration did not affect the elution of the four studied amino acids. Considering the Luna HILIC column, the retention times of the amino acids were too close to each other to ensure a separation among each other. Lastly, the Luna C18 column revealed to be useful to separate amino acids in a gradient mode, being the variation of the mobile phase composition in the organic solvent concentration (ACN). Luna C18 was the column used to separate the amino acids in the real samples and the mobile phase had acidified water and ACN. The gradient consisted in the following program: 0 – 2 min: 5% (V/V) ACN, 2 – 8 min: 5 – 2 % (V/V) ACN, 8 – 16 min: 2% (V/V) ACN, 16 – 20 min: 2 – 20 % (V/V) ACN, 20 – 35 min: 20 – 35 % (V/V) ACN. The aerosols samples were collected by using three passive samplers placed in two different locations in Aveiro and each sampler had two filters - one faced up and the other faced down. After the sampling, the water-soluble organic compounds was extracted by dissolution in ultra-pure water, sonication bath and filtration. The resulting filtered solutions were diluted in acidified water for the chromatographic separation. The results from liquid chromatography revealed the presence of the amino acids, although it was not possible to identify each one of them individually. The chromatograms and the fluorescence spectra showed the existence of some patterns: the samples that correspond to the up filters had more intense peaks and signals, revealing that the up filters collected more organic matter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays it is still difficult to perform an early and accurate diagnosis of dementia, therefore many research focus on the finding of new dementia biomarkers that can aid in that purpose. So scientists try to find a noninvasive, rapid, and relatively inexpensive procedures for early diagnosis purpose. Several studies demonstrated that the utilization of spectroscopic techniques, such as Fourier Transform Infrared Spectroscopy (FTIR) and Raman spectroscopy could be an useful and accurate procedure to diagnose dementia. As several biochemical mechanisms related to neurodegeneration and dementia can lead to changes in plasma components and others peripheral body fluids, blood-based samples and spectroscopic analyses can be used as a more simple and less invasive technique. This work is intended to confirm some of the hypotheses of previous studies in which FTIR was used in the study of plasma samples of possible patient with AD and respective controls and verify the reproducibility of this spectroscopic technique in the analysis of such samples. Through the spectroscopic analysis combined with multivariate analysis it is possible to discriminate controls and demented samples and identify key spectroscopic differences between these two groups of samples which allows the identification of metabolites altered in this disease. It can be concluded that there are three spectral regions, 3500-2700 cm -1, 1800-1400 cm-1 and 1200-900 cm-1 where it can be extracted relevant spectroscopic information. In the first region, the main conclusion that is possible to take is that there is an unbalance between the content of saturated and unsaturated lipids. In the 1800-1400 cm-1 region it is possible to see the presence of protein aggregates and the change in protein conformation for highly stable parallel β-sheet. The last region showed the presence of products of lipid peroxidation related to impairment of membranes, and nucleic acids oxidative damage. FTIR technique and the information gathered in this work can be used in the construction of classification models that may be used for the diagnosis of cognitive dysfunction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta dissertação teve como objetivo a produção e caracterização física de fibras e nanotubos de BiFeO3 e FeNbO4. Para o desenvolvimento destes materiais utilizou-se a técnica de fusão com laser (LFZ), o método sol-gel (Pechini) e o método de poros absorventes. As amostras obtidas foram sujeitas a uma caracterização estrutural por difração de raios-X e espetroscopia de Raman, morfológica por microscopia electrónica de varrimento e elétrica por medidas de constante dielétrica. Os resultados obtidos com a técnica de difração de raios-X mostraram que o gel com tratamento a 750 ºC é polifásico. Para conseguir produzir nanotubos escolheu-se o LaCoO3 como material alternativo. Usando a técnica de fusão de zona com laser (LFZ) obtiveram-se fibras de BiFeO3, FeNbO4 e compósitos de BiFeO3+FeNbO4. Com esta técnica foram crescidas fibras a várias velocidades (5, 10, 25, 50, 100 e 200 mm/h), tendo os resultados obtidos com a difração de raios-X evidenciado que todas as amostras obtidas são polifásicas, sendo a amostra de 10 mm/h para o BiFeO3 e a de 5 mm/h para o FeNbO4 as que apresentam melhores propriedades. As amostras de 5 mm/h de todos os compósitos são aquelas que possuem menor quantidade de segundas fases e portanto foram alvo de estudo mais aprofundado. A caracterização dielétrica permitiu verificar que todas as amostras apresentam fenómenos de relaxação dielétrica. Verifica-se também que para o BiFeO3 a constante dielétrica é superior na amostra crescida à velocidade de 10 mm/h, para o FeNbO4 é superior na amostra crescida a 5 mm/h e nos compósitos a amostra com 75% de BiFeO3 e 25% de FeNbO4 apresenta um comportamento diferente das restantes, eventualmente devido à sua microestrutura singular.