2 resultados para Imunidade passiva

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Hamstring strain injuries (HSI) are one of the most common injuries in a wide variety of running-sports, resulting in a considerable loss of competition and training time. One of the most problematic consequences regarding HSI is the recurrence rate and its non-decrease over the past decades, despite increasing evidence. Recent studies also found several maladaptations post-HSI probably due to neuromuscular inhibition and it has been proposed that these adaptations post-injury may contribute as risk factors for the injury-reinjury cycle and high recurrence rates. Furthermore it has been recently proposed not to disregard the inter-relationship between these adaptations and risk-factors post-injury in order to better understand the mechanisms of this complex injury. Objective: To determine, analyze and correlate neuromuscular adaptations in amateur football players with prior history of HSI per comparison to uninjured athletes in similar conditions. Methodology: Every participant was subjected to isokinetic concentric (60 and 240deg.sec) and eccentric (30 and 120deg.sec¯¹) testing, and peak torque, angle of peak torque and hamstrings to quadriceps (H:Q) conventional ratios were measured, myoelectrical activity of Bicep Femoris (BF) and Medial Hamstrings (MH) were also measured during isokinetic eccentric testing at both velocities and muscle activation percentages were calculated at 30, 50 and 100ms after onset of contraction. Furthermore active and passive knee extension, knee joint position sense (JPS) test, triple-hop distance (THD) test and core stability (flexors and extensors endurance, right and left side bridge test) were used and correlated. Results: Seventeen players have participated in this study: 10 athletes with prior history of HSI, composing the Hamstring injury group (HG) and 7 athletes without prior severe injuries as control group (CG). We found statistical significant differences between HG injured and uninjured sides in the BF myoelectrical activity at almost all times in both velocities and between HG injured and CG non-dominant sides at 100ms in eccentric 120deg.sec¯¹ velocity (p<.05). We found no differences in MH activity. Regarding proprioception we found differences between the HG injured and uninjured sides (p=.027). We found no differences in the rest of used tests. However, significant correlation between myoelectrical activation at 100ms in 120deg.sec¯¹ testing and JPS with initial position at 90º (r-.372; p=0.031) was found, as well as between isokinetic H:Q ratio at 240deg.sec and THD score (r=-.345; p=.045). Conclusion: We found significant differences that support previous research regarding neuromuscular adaptations and BF inhibition post-HSI. Moreover, to our knowledge, this was the first study that found correlation between these adaptations, and may open a door to new perspectives and future studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A necessidade de controlar de forma rápida, eficaz e precisa a qualidade de líquidos, principalmente a água, um bem essencial para os seres humanos, conduziu ao desenvolvimento de dispositivos capazes de relacionar a medição de parâmetros físicos com a qualidade da água. Estes dispositivos devem ser capazes de monitorizar os inúmeros parâmetros necessários para aferir a qualidade do líquido, como a turvação, índice de refração, concentração de sedimentos e propriedades cromáticas. Desta forma devem-se recorrer a sensores multiparâmetros. A tecnologia baseada em POF (fibra ótica polimérica) tem sido apontada com elevado potencial no desenvolvimento de sensores óticos nas mais variadas aplicações dado o seu baixo custo, imunidade a interferências eletromagnéticas e flexibilidade. Neste trabalho é proposto um sensor POF multiparâmetro capaz de reunir num único dispositivo a capacidade de medição de altos e baixos valores de turvação, assim como ter a capacidade de medir vários parâmetros em simultâneo e em tempo real. Os resultados permitem avaliar o aumento da capacidade de gama dinâmica de turvação e concentração de sedimentos face aos sensores multiparâmetros já comercializados, uma vez que houve uma boa resposta por parte do sensor para altos e para baixos valores. Um método utilizado para descorrelacionar os diferentes parâmetros foi aplicado com sucesso. A WATGRID LDA. pretende, partindo deste tipo de sensores, disponibilizar aos seus clientes soluções (plataformas) inteligentes e integradas para avaliação e gestão da qualidade dos líquidos para consumo (e.g. água e vinho). Estas soluções irão permitir que os clientes da WATGRID LDA. aumentem a sua eficiência, a qualidade do seu produto e tenham um maior controlo do processo ao mesmo tempo que reduzem custos.