2 resultados para Heparina de baixo peso molecular

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The immune system is able to produce antibodies, which have the capacity to recognize and to bind to foreign molecules or pathogenic organisms. Currently, there are a diversity of diseases that can be treated with antibodies, like immunoglobulins G (IgG). Thereby, the development of cost-efficient processes for their extraction and purification is an area of main interest in biotechnology. Aqueous biphasic systems (ABS) have been investigated for this purpose, once they allow the reduction of costs and the number of steps involved in the process, when compared with conventional methods. Nevertheless, typical ABS have not showed to be selective, resulting in low purification factors and yields. In this context, the addition of ionic liquids (ILs) as adjuvants can be a viable and potential alternative to tailor the selectivity of these systems. In this work, ABS composed of polyethylene glycol (PEG) of different molecular weight, and a biodegradable salt (potassium citrate) using ILs as adjuvants (5 wt%), were studied for the extraction and purification of IgG from a rabbit source. Initially, it was tested the extraction time, the effect on the molecular weight of PEG in a buffer solution of K3C6H5O7/C6H8O7 at pH≈7, and the effect of pH (59) on the yield (YIgG) and extraction efficiency (EEIgG%) of IgG. The best results regarding EEIgG% were achieved with a centrifugation step at 1000 rpm, during 10 min, in order to promote the separation of phases followed by 120 min of equilibrium. This procedure was then applied to the remaining experiments. The results obtained in the study of PEGs with different molecular weights, revealed a high affinity of IgG for the PEG-rich phase, and particularly for PEGs of lower molecular weight (EEIgG% of 96 % with PEG 400). On the other hand, the variation of pH in the buffer solution did not show a significant effect on the EEIgG%. Finally, it was evaluated the influence of the addition of different ILs (5% wt) on the IgG extraction in ABS composed of PEG 400 at pH≈7. In these studies, it was possible to obtain EEIgG% of 100% with the ILs composed of the anions [TOS]-, [CH3CO2]-and Cl-, although the obtained YIgG% were lower than 40%. On the other hand, the ILs composed of the anions Br-, as well as of the cation [C10mim]+, although not leading to EEIgG% of 100%, provide an increase in the YIgG%. ABS composed of PEG, a biodegradable organic salt and ILs as adjuvants, revealed to be an alternative and promising method to purify IgG. However, additional studies are still required in order to reduce the loss of IgG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Streptococcus pneumoniae is a human pathobiont that colonizes the nasopharynx. S. pneumoniae is responsible for causing non-invasive and invasive disease such as otitis, pneumonia, meningitis, and sepsis, being a leading cause of infectious diseases worldwide. Due to similarities with closely related species sharing the same niche, it may be a challenge to correctly distinguish S. pneumoniae from its relatives when using only non-culture based methods such as real time PCR (qPCR). In 2007, a molecular method targeting the major autolysin (lytA) of S. pneumoniae by a qPCR assay was proposed by Carvalho and collaborators to identify pneumococcus. Since then, this method has been widely used worldwide. In 2013, the gene encoding for the ABC iron transporter lipoprotein PiaA, was proposed by Trzcinzki and collaborators to be used in parallel with the lytA qPCR assay. However, the presence of lytA gene homologues has been described in closely related species such as S. pseudopneumoniae and S. mitis and the presence of piaA gene is not ubiquitous between S. pneumoniae. The hyaluronate lyase gene (hylA) has been described to be ubiquitous in S. pneumoniae. This gene has not been used so far as a target for the identification of S. pneumoniae. The aims of our study were to evaluate the specificity, sensitivity, positive predicted value (PPV) and negative predicted value (NPV) of the lytA and piaA qPCR methods; design and implement a new assay targeting the hylA gene and evaluate the same parameters above described; analyze the assays independently and the possible combinations to access what is the best approach using qPCR to identify S. pneumoniae. A total of 278 previously characterized strains were tested: 61 S. pseudopneumoniae, 37 Viridans group strains, 30 type strains from other streptococcal species and 150 S. pneumoniae strains. The collection included both carriage and disease isolates. By Mulilocus Sequence Analysis (MLSA) we confirmed that strains of S. pseudopneumoniae could be misidentified as S. pneumoniae when lytA qPCR assay is used. The results showed that as a single target, lytA had the best combination of specificity, sensitivity, PPV and NPV being, 98.5%, 100.0%, 98.7% and 100.0% respectively. The combination of targets with the best values of specificity, sensibility, PPV and NPV were lytA and piaA, with 100.0%, 93.3%, 97.9% and 92.6%, respectively. Nonetheless by MLSA we confirmed that strains of S. pseudopneumoniae could be misidentified as S. pneumoniae and some capsulated (23F, 6B and 11A) and non-capsulated S. pneumoniae were not Identified using this assay. The hylA gene as a single target had the lowest PPV. Nonetheless it was capable to correctly identify all S. pneumoniae.