1 resultado para G METHOD

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The immune system is able to produce antibodies, which have the capacity to recognize and to bind to foreign molecules or pathogenic organisms. Currently, there are a diversity of diseases that can be treated with antibodies, like immunoglobulins G (IgG). Thereby, the development of cost-efficient processes for their extraction and purification is an area of main interest in biotechnology. Aqueous biphasic systems (ABS) have been investigated for this purpose, once they allow the reduction of costs and the number of steps involved in the process, when compared with conventional methods. Nevertheless, typical ABS have not showed to be selective, resulting in low purification factors and yields. In this context, the addition of ionic liquids (ILs) as adjuvants can be a viable and potential alternative to tailor the selectivity of these systems. In this work, ABS composed of polyethylene glycol (PEG) of different molecular weight, and a biodegradable salt (potassium citrate) using ILs as adjuvants (5 wt%), were studied for the extraction and purification of IgG from a rabbit source. Initially, it was tested the extraction time, the effect on the molecular weight of PEG in a buffer solution of K3C6H5O7/C6H8O7 at pH≈7, and the effect of pH (59) on the yield (YIgG) and extraction efficiency (EEIgG%) of IgG. The best results regarding EEIgG% were achieved with a centrifugation step at 1000 rpm, during 10 min, in order to promote the separation of phases followed by 120 min of equilibrium. This procedure was then applied to the remaining experiments. The results obtained in the study of PEGs with different molecular weights, revealed a high affinity of IgG for the PEG-rich phase, and particularly for PEGs of lower molecular weight (EEIgG% of 96 % with PEG 400). On the other hand, the variation of pH in the buffer solution did not show a significant effect on the EEIgG%. Finally, it was evaluated the influence of the addition of different ILs (5% wt) on the IgG extraction in ABS composed of PEG 400 at pH≈7. In these studies, it was possible to obtain EEIgG% of 100% with the ILs composed of the anions [TOS]-, [CH3CO2]-and Cl-, although the obtained YIgG% were lower than 40%. On the other hand, the ILs composed of the anions Br-, as well as of the cation [C10mim]+, although not leading to EEIgG% of 100%, provide an increase in the YIgG%. ABS composed of PEG, a biodegradable organic salt and ILs as adjuvants, revealed to be an alternative and promising method to purify IgG. However, additional studies are still required in order to reduce the loss of IgG.