2 resultados para Confiabilidade (Mecânica)

em Repositório Institucional da Universidade de Aveiro - Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The planar design of solid oxide fuel cell (SOFC) is the most promising one due to its easier fabrication, improved performance and relatively high power density. In planar SOFCs and other solid-electrolyte devices, gas-tight seals must be formed along the edges of each cell and between the stack and gas manifolds. Glass and glass-ceramic (GC), in particular alkaline-earth alumino silicate based glasses and GCs, are becoming the most promising materials for gas-tight sealing applications in SOFCs. Besides the development of new glass-based materials, new additional concepts are required to overcome the challenges being faced by the currently existing sealant technology. The present work deals with the development of glasses- and GCs-based materials to be used as a sealants for SOFCs and other electrochemical functional applications. In this pursuit, various glasses and GCs in the field of diopside crystalline materials have been synthesized and characterized by a wide array of techniques. All the glasses were prepared by melt-quenching technique while GCs were produced by sintering of glass powder compacts at the temperature ranges from 800−900 ºC for 1−1000 h. Furthermore, the influence of various ionic substitutions, especially SrO for CaO, and Ln2O3 (Ln=La, Nd, Gd, and Yb), for MgO + SiO2 in Al-containing diopside on the structure, sintering and crystallization behaviour of glasses and properties of resultant GCs has been investigated, in relevance with final application as sealants in SOFC. From the results obtained in the study of diopside-based glasses, a bilayered concept of GC sealant is proposed to overcome the challenges being faced by (SOFCs). The systems designated as Gd−0.3 (in mol%: 20.62MgO−18.05CaO−7.74SrO−46.40SiO2−1.29Al2O3 − 2.04 B2O3−3.87Gd2O3) and Sr−0.3 (in mol%: 24.54 MgO−14.73 CaO−7.36 SrO−0.55 BaO−47.73 SiO2−1.23 Al2O3−1.23 La2O3−1.79 B2O3−0.84 NiO) have been utilized to realize the bi-layer concept. Both GCs exhibit similar thermal properties, while differing in their amorphous fractions, revealed excellent thermal stability along a period of 1,000 h. They also bonded well to the metallic interconnect (Crofer22APU) and 8 mol% yttrium stabilized zirconium (8YSZ) ceramic electrolyte without forming undesirable interfacial layers at the joints of SOFC components and GC. Two separated layers composed of glasses (Gd−0.3 and Sr−0.3) were prepared and deposited onto interconnect materials using a tape casting approach. The bi-layered GC showed good wetting and bonding ability to Crofer22APU plate, suitable thermal expansion coefficient (9.7–11.1 × 10–6 K−1), mechanical reliability, high electrical resistivity, and strong adhesion to the SOFC componets. All these features confirm the good suitability of the investigated bi-layered sealant system for SOFC applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uma das causas de insucesso nas artroplastias do joelho está relacionada com a dor que os doentes sentem a curto e/ou longo prazo. A dor tanto pode ser devida a infecção ou descolamento, como pode estar presente sem qualquer um destes factores, provocando a substituição da prótese. Existem estudos de origem clínica que relatam uma percentagem, que se pode considerar relevante, de dor na extremidade da haste, quer na zona da tíbia quer no fémur [1-3]. A nível ósseo, a cintigrafia pode mostrar as alterações metabólicas locais, antes de qualquer tradução radiográfica [4]. O aumento da carga, a nível ósseo, estimula localmente a actividade osteoblástica [4]. Esta estimulação pode originar dor local, como demonstrado num caso clínico por Fonseca et al. [5], referente a um doente com dor na extremidade da haste de uma prótese do joelho e onde a cintigrafia com Tc 99m [5] mostrava uma actividade celular mais intensa em torno da extremidade. O presente estudo teve como objectivo verificar até que ponto é possível estabelecer uma relação entre o sintoma dor e o comportamento biomecânico da haste da prótese do joelho e, particularmente, na sua extremidade. A análise relativa ao nível de tensões no osso, em torno da haste tibial, comparativamente ao valor do osso intacto para o mesmo tipo de carga e localização, foi realizada utilizando a aplicação de análise estrutural HyperWorks (Altair Engineering Inc.). Um estudo posterior, relativo à forma e material da extremidade da haste levou à conclusão de que é possível uma melhor uniformização das tensões no osso, podendo-se desta forma aproximar às tensões fisiológicas. Neste sentido, a forma geometral da haste deverá ser objecto de optimização, que poderá incluir materiais poliméricos, de menor rigidez, na ponta distal do implante.