19 resultados para turf visual quality
Resumo:
Purpose
To evaluate the impact of the position of an asymmetric multifocal near segment on visual quality.
Setting
Cathedral Eye Clinic, Belfast, United Kingdom.
Design
Retrospective comparative case series.
Methods
Data from consecutive patients who had bilateral implantation of the Lentis Mplus LS-312 multifocal intraocular lens were divided into 2 groups. One group received inferonasal near-segment placement and the other, superotemporal near-segment placement. A +3.00 diopter (D) reading addition (add) was used in all eyes. The main outcome measures included uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), contrast sensitivity, and quality of vision. Follow-up was 3 months.
Results
Patients ranged in age from 43 to 76 years. The inferonasal group comprised 80 eyes (40 patients) and the superotemporal group, 76 eyes (38 patients). The mean 3-month spherical equivalent was −0.11 D ± 0.49 (SD) in the inferonasal group and −0.18 ± 0.46 D in the superotemporal group. The mean postoperative UDVA was 0.14 ± 0.10 logMAR and 0.18 ± 0.15 logMAR, respectively. The mean monocular UNVA was 0.21 ± 0.14 logRAD and 0.24 ± 0.13 logRAD, respectively. No significant differences were observed in the higher-order aberrations, total Strehl ratio (point-spread function), or modulation transfer function between the groups. Dysphotopic symptoms measured with a validated quality-of-vision questionnaire were not significantly different between groups.
Conclusion
Positioning of the near add did not significantly affect objective or subjective visual function parameters.
Resumo:
In this paper, a new blind and readable H.264 compressed domain watermarking scheme is proposed in which the embedding/extracting is performed using the syntactic elements of the compressed bit stream. As a result, it is not necessary to fully decode a compressed video stream both in the embedding and extracting processes. The method also presents an inexpensive spatiotemporal analysis that selects the appropriate submacroblocks for embedding, increasing watermark robustness while reducing its impact on visual quality. Meanwhile, the proposed method prevents bit-rate increase and restricts it within an acceptable limit by selecting appropriate quantized residuals for watermark insertion. Regarding watermarking demands such as imperceptibility, bit-rate control, and appropriate level of security, a priority matrix is defined which can be adjusted based on the application requirements. The resulted flexibility expands the usability of the proposed method.
Visual functioning and quality of life in the subfoveal radiotherapy study (SFRADS): SFRADS report 2
Resumo:
Aims: To determine whether or not self reported visual functioning and quality of life in patients with choroidal neovascularisation caused by age related macular degeneration (AMD) is better in those treated with 12 Gy external beam radiotherapy in comparison with untreated subjects. Methods: A multicentre single masked randomised controlled trial of 12 Gy of external beam radiation therapy (EBRT) delivered as 6x2 Gy fractions to the macula of an affected eye versus observation. Patients with AMD, aged 60 years or over, in three UK hospital units, who had subfoveal CNV and a visual acuity equal to or better than 6/60 (logMAR 1.0). Methods: Data from 199 eligible participants who were randomly assigned to 12 Gy teletherapy or observation were available for analysis. Visual function assessment, ophthalmic examination, and fundus fluorescein angiography were undertaken at baseline and at 3, 6, 12, and 24 months after study entry. To assess patient centred outcomes, subjects were asked to complete the Daily Living Tasks Dependent on Vision (DLTV) and the SF-36 questionnaires at baseline, 6, 12, and 24 months after enrolment to the study. Cross sectional and longitudinal analyses were conducted using arm of study as grouping variable. Regression analysis was employed to adjust for the effect of baseline co-variates on outcome at 12 months and 24 months. Results: Both control and treated subjects had significant losses in visual functioning as seen by a progressive decline in mean scores in the four dimensions of the DLTV. There were no statistically significant differences between treatment and control subjects in any of dimensions of the DLTV at 12 months or 24 months after study entry. Regression analysis confirmed that treatment status had no effect on the change in DLTV dimensional scores. Conclusions: The small benefits noted in clinical measures of vision in treated eyes did not translate into better self reported visual functioning in patients who received treatment when compared with the control arm. These findings have implications for the design of future clinical trials and studies.
Resumo:
BACKGROUND: To evaluate cataract surgical outcomes in four rural districts of Ha Tinh Province, Vietnam. DESIGN: Cross-sectional study. PARTICIPANTS: Post-cataract surgery patients sampled randomly from facilities in four rural districts of Ha Tinh Province >3 months after surgery. MAIN OUTCOME MEASURES: Postoperative visual acuity (VA), visual function and quality of life. RESULTS: Among 412 patients, the mean age was 74.5 ± 9.4 years, 67% (276) were female, and 377 (91.5%) received intraocular lenses (IOL). Nearly two-thirds of patients had no postoperative visits after discharge. Postoperatively, more than 40% of eyes had presenting VA <6/18, while 20% remained <6/60. The mean self-reported visual function and quality of life for all patients were 68.7 ± 23.8 and 73.8 ± 21.6, respectively. Most patients (89.5%) were satisfied with surgery and the majority (94.4%) would recommend surgery to others. One-third of patients paid ≥$US50 for surgery. In multiple regression modelling, older age (P < 0.01), intraoperative complications (P < 0.01) and failure to receive an IOL (P < 0.01) were associated with postoperative VA <6/60. CONCLUSION: Satisfaction with surgery was high, and many patients were willing to pay for their operations. Poor visual outcomes were common; however, and better surgical training is needed to reduce complications and their impact on visual outcomes. More intensive postoperative follow-up may also be beneficial. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.
Resumo:
Background: Cough is a prominent symptom across a range of common chronic respiratory diseases and impacts considerably on patient health status.
Methods: We undertook a cross-sectional comparison of scores from two cough-specific health-related quality of life (HRQoL) questionnaires, the Leicester Cough Questionnaire (LCQ), and the Cough Quality of Life Questionnaire (CQLQ), together with a generic HRQoL measure, the EuroQol. Questionnaires were administered to and spirometry performed on 147 outpatients with chronic cough (n = 83), COPD (n = 18), asthma (n = 20), and bronchiectasis (n = 26).
Results: There was no significant difference in the LCQ and CQLQ total scores between groups (p = 0.24 and p = 0.26, respectively). Exploratory analyses of questionnaire subdomains revealed differences in psychosocial issues and functional impairment between the four groups (p = 0.01 and p = 0.05, respectively). CQLQ scores indicated that chronic coughers have more psychosocial issues than patients with bronchiectasis (p = 0.03) but less functional impairment than COPD patients (p = 0.04). There was a significant difference in generic health status across the four disease groups (p = 0.04), with poorest health status in COPD patients. A significant inverse correlation was observed between CQLQ and LCQ in each disease group (chronic cough r = - 0.56, p < 0.001; COPD r = - 0.49, p = 0.04; asthma r = - 0.94, p < 0.001; and bronchiectasis r = - 0.88, p < 0.001). There was no correlation between cough questionnaire scores and FEV1 in any group, although a significant correlation between EuroQol visual analog scale component and FEV1 (r = 0.639, p = 0.004) was observed in COPD patients.
Conclusion: Cough adversely affects health status across a range of common respiratory diseases. The LCQ and CQLQ can each provide important additional information concerning the impact of cough.
Resumo:
Purpose: To quantify decreases in health-related quality of life (HRQoL) for given deterioration in clinical measures of vision; to describe the shape of these relationships; and to test whether the gradients of these relationships change with duration of visual loss.
Resumo:
Contesting animals typically gather information about the resource value and that information affects fight motivation. However, it is possible that particular resource characteristics alter the ability to fight independently of the motivation. Using hermit crabs, we investigate how the resource in terms of shell quality affects both motivation and ability to fight. These crabs fight for shells, but those shells have to be carried and may impose physiological costs that impede fight vigour. We find that the shell has different effects on motivation and ability. Potential attackers in very small shells were highly motivated to attack but, rather than having enhanced ability, unexpectedly quickly fatigued and subsequently were not more successful in the fights than were crabs in larger shells. We also examined whether defending crabs could gather information about the attacker's shell from the vigour of the attack. Defending crabs gave up quickly when a potential gain had been assessed, indicating that such information had been gathered. However, there was no indication that this could be owing to the activity of the attacker and the information is probably gathered via visual assessment of the shell.
Resumo:
Late age-related maculopathy (ARM) is responsible for the majority of blind registrations in the Western world among persons over 50 years of age. It has devastating effects on quality of life and independence and is becoming a major public health concern. Current treatment options are limited and most aim to slow progression rather than restore vision; therefore, early detection to identify those patients most suitable for these interventions is essential. In this work, we review the literature encompassing the investigation of visual function in ARM in order to highlight those visual function parameters which are affected very early in the disease process. We pay particular attention to measures of acuity, contrast sensitivity (CS), cone function, electrophysiology, visual adaptation, central visual field sensitivity and metamorphopsia. We also consider the impact of bilateral late ARM on visual function as well as the relationship between measures of vision function and self-reported visual functioning. Much interest has centred on the identification of functional changes which may predict progression to neovascular disease; therefore, we outline the longitudinal studies, which to date have reported dark-adaptation time, short-wavelength cone sensitivity, colour-match area effect, dark-adapted foveal sensitivity, foveal flicker sensitivity, slow recovery from glare and slower foveal electroretinogram implicit time as functional risk factors for the development of neovascular disease. Despite progress in this area, we emphasise the need for longitudinal studies designed in light of developments in disease classification and retinal imaging, which would ensure the correct classification of cases and controls, and provide increased understanding of the natural course and progression of the disease and further elucidate the structure-function relationships in this devastating disorder.
Resumo:
PURPOSE: To investigate the quality of life and priorities of patients with glaucoma.
METHODS: Patients diagnosed with glaucoma and no other ocular comorbidity were consecutively recruited. Clinical information was collected. Participants were asked to complete three questionnaires: EuroQuol (EQ-5D), time tradeoff (TTO), and choice-based conjoint analysis. The latter used five-attribute outcomes: (1) reading and seeing detail, (2) peripheral vision, (3) darkness and glare, (4) household chores, and (5) outdoor mobility. Visual field loss was estimated by using binocular integrated visual fields (IVFs).
RESULTS: Of 84 patients invited to participate, 72 were enrolled in the study. The conjoint utilities showed that the two main priorities were "reading and seeing detail" and "outdoor mobility." This rank order was stable across all segmentations of the data by demographic or visual state. However, the relative emphasis of these priorities changed with increasing visual field loss, with concerns for central vision increasing, whereas those for outdoor mobility decreased. Two subgroups of patients with differing priorities on the two main attributes were identified. Only 17% of patients (those with poorer visual acuity) were prepared to consider TTO. A principal component analysis revealed relatively independent components (i.e., low correlations) between the three different methodologies for assessing quality of life.
CONCLUSIONS: Assessments of quality of life using different methodologies have been shown to produce different outcomes with low intercorrelations between them. Only a minority of patients were prepared to trade time for a return to normal vision. Conjoint analysis showed two subgroups with different priorities. Severity of glaucoma influenced the relative importance of priorities.
Resumo:
Objective: The purpose of this study was to estimate costs and quality of life (QoL) of late-stage glaucoma patients in 4 European countries. Methods: Retrospective review of medical charts of patients with POAG who were followed in a low-vision or vision rehabilitation center in one of 4 countries for at least 1 year was used to determine patient characteristics, health status, and health care resource use. Visual impairment was measured by best-corrected visual acuity (Snellen score). Patients were also interviewed over the telephone in order to assess their health-related QoL (using EuroQol EQ-5D) and use of resources including: the number of visits to rehabilitation centers, visits to hospital and non-hospital specialists, the use of low-vision devices, medication, tests, and the use of hired home help. The costs associated with resource use were calculated from the perspective of a third-party payer of health and social care based on resource usage and unit costs in each country. Results: Patients undergoing visual rehabilitation in France (n=21), Denmark (n=59), Germany (n=60), and the United Kingdom (n=22) were identified, interviewed and had their medical charts reviewed. Annual maintenance costs of late-stage glaucoma amounted to €830 (±445) on average. Average home help costs were more than 3 times higher. QoL, on average, was 0.65 (±0.28). QoL was positively correlated with the level of visual acuity in the patients' best eye. On the other hand, visual acuity was also positively correlated to health care costs, but negatively correlated to costs of home help. Conclusions: The study was limited by its observational, uncontrolled design. The finding that late-stage glaucoma is associated with higher home help costs than health care maintenance costs suggests that potential savings from a better preventive treatment are to be found for social care payers rather than health care payers. © 2008 Informa UK Ltd All rights reserved.
Resumo:
PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (? = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.