47 resultados para time measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper is to develop a new generation of extruder control system for recycled materials which has ability to automatically maintain constant a polymer melt viscosity of mixed recycled polymers during extrusion, regardless of variations in the Melt Flow Index (MFI) of recycled mixed grade high density polyethylene (HDPE) feedstock. The variations in MFI are due to differences in the source of the recycled material used. The work describes how melt viscosity for specific extruder/die system is calculated in real time using the rheological properties of the materials, the pressure drop through the extruder die and the actual throughput measurements using a gravimetric loss-in-weight hopper feeder. A closed-loop controller is also developed to automatically regulate screw speed and barrel temperature profile to achieve constant viscosity and enable consistent processing of variable grade recycled HDPE materials. Such a system will improve processability of mixed MFI polymers may also reduce the risk of polymer melt degradation, reduce producing large volumes of scrap/waste and lead to improvement in product quality. The experimental results of real time viscosity measurement and control using a 38 mm single screw extruder with different recycled HDPEs with widely different MFIs are reported in this work.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a novel detection method for broken rotor bar fault (BRB) in induction motors based on Estimation of Signal Parameters via Rotational Invariance Technique (ESPRIT) and Simulated Annealing Algorithm (SAA). The performance of ESPRIT is tested with simulated stator current signal of an induction motor with BRB. It shows that even with a short-time measurement data, the technique is capable of correctly identifying the frequencies of the BRB characteristic components but with a low accuracy on the amplitudes and initial phases of those components. SAA is then used to determine their amplitudes and initial phases and shows satisfactory results. Finally, experiments on a 3kW, 380V, 50Hz induction motor are conducted to demonstrate the effectiveness of the ESPRIT-SAA-based method in detecting BRB with short-time measurement data. It proves that the proposed method is a promising choice for BRB detection in induction motors operating with small slip and fluctuant load.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

MIR spectroscopy is an established technique which has process monitoring applications in the chemical and pharmaceutical industries. Previous attempts to utilise the technology for monitoring of AD plants were of limited success, with operation hindered by severe clogging of the probe.

Novel fittings, which allow a probe to be withdrawn from the process fluid, cleaned and recalibrated in situ have now been developed to combat this clogging problem. This has allowed a spectroscopic probe to be used successfully in lab scale digesters for real time measurement of VFA concentration, a key parameter to the stability of AD plants.

This project will demonstrate the technology at a farm scale AD plant for the first time. Both real-time measurements of VFA concentrations and parameters currently measured by plant operators will be available, leading to state-of-the-art monitoring and control of the AD plant. With the improved monitoring that this probe will deliver, it is hoped to realise a 10% increase in biogas production without compromising the stability of the process. This will deliver both economic and environmental benefits.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The preventive knowledge of serviceability times is a critical factor for the quantification of after-sales services costs of a vehicle. Predetermined motion time system are frequently used to set labor rates in industry by quantifying the amount of time required to perform specific tasks. The first such system is known as Methods-time measurement (MTM). Several variants of MTM have been developed differing from each other on their level of focus. Among them MTM-UAS is suitable for processes that average around 1-3 min. However experimental tests carried out by the authors in Elasis (Research Center of FIAT Group) demonstrate that MTM-UAS is not the optimal approach to measure serviceability times. The reason is that it doesn't take into account ergonomic factors. In the present paper the authors propose to correct the MTM-UAS method including in the task analysis the study of human postures and efforts. The proposed approach allows to estimate with an "acceptable" error the time needed to perform maintenance tasks since the first phases of product design, by working on Digital Mock-up and human models in virtual environment. As a byproduct of that analysis, it is possible to obtain a list of maintenance times in order to preventively set after-sales service costs. © 2012 Springer-Verlag.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Statistical distributions have been extensively used in modeling fading effects in conventional and modern wireless communications. In the present work, we propose a novel κ − µ composite shadowed fading model, which is based on the valid assumption that the mean signal power follows the inverse gamma distribution instead of the lognormal or commonly used gamma distributions. This distribution has a simple relationship with the gamma distribution, but most importantly, its semi heavy-tailed characteristics constitute it suitable for applications relating to modeling of shadowed fading. Furthermore, the derived probability density function of the κ − µ / inverse gamma composite distribution admits a rather simple algebraic representation that renders it convenient to handle both analytically and numerically. The validity and utility of this fading model are demonstrated by means of modeling the fading effects encountered in body centric communications channels, which have been known to be susceptible to the shadowing effect. To this end, extensive comparisons are provided between theoretical and respective real-time measurement results. It is shown that these comparisons exhibit accurate fitting of the new model for various measurement set ups that correspond to realistic communication scenarios.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new approach to the search for residues of unknown growth promoting agents such as anabolic steroids and -agonists in feed is presented. Following primary extraction and clean-up, samples are separated using gradient liquid chromatography (LC). The effluent is split towards two identical 96-well fraction collectors and an optional electrospray quadrupole time-of-flight mass spectrometry (QTOFMS) system for accurate mass measurement. One 96-well plate is used for a bioassay (enzyme-immuno assay, receptor assay) and will detect the bioactivity and position of the relevant peak in the chromatogram. The positive well in the second 96-well plate is used for identification by LC/QTOFMS/MS. The value of this LC/bioassay/QTOFMS/MS methodology is highlighted by the finding and structure elucidation of a new -agonist in a feed extract.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The characterization of thermocouple sensors for temperature measurement in varying-flow environments is a challenging problem. Recently, the authors introduced novel difference-equation-based algorithms that allow in situ characterization of temperature measurement probes consisting of two-thermocouple sensors with differing time constants. In particular, a linear least squares (LS) lambda formulation of the characterization problem, which yields unbiased estimates when identified using generalized total LS, was introduced. These algorithms assume that time constants do not change during operation and are, therefore, appropriate for temperature measurement in homogenous constant-velocity liquid or gas flows. This paper develops an alternative ß-formulation of the characterization problem that has the major advantage of allowing exploitation of a priori knowledge of the ratio of the sensor time constants, thereby facilitating the implementation of computationally efficient algorithms that are less sensitive to measurement noise. A number of variants of the ß-formulation are developed, and appropriate unbiased estimators are identified. Monte Carlo simulation results are used to support the analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In quantum tunnelling, what appears to be an infinitely fast barrier traversal can be explained in terms of an Aharonov-like weak measurement of the tunnelling time, in which the role of the pointer is played by the particle's own coordinate. A relativistic wave packet is shown to be reshaped through a series of subluminal shifts which together produce an anomalous 'superluminal' result.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the case of a simple quantum system, we investigate the possibility of defining meaningful probabilities for a quantity that cannot be represented by a Hermitian operator. We find that the consistent-histories approach, recently applied to the case of quantum traversal time [N. Yamada, Phys. Rev. Lett. 83, 3350 (1999)], does not provide a suitable criterion and we dispute Yamada's claim of finding a simple solution to the tunneling-time problem. Rather, we define the probabilities for certain types of generally nonorthogonal decomposition of the system's quantum state. These relate to the interaction between the system and its environment, can be observed in a generalized von Neumann measurement, and are consistent with a particular class of positive-operator-valued measures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The harsh environment presented by engines, particularly in the exhaust systems, often necessitates the use of robust and therefore low bandwidth temperature sensors. Consequently, high frequencies are attenuated in the output. One technique for addressing this problem involves measuring the gas temperature using two sensors with different time-constants and mathematically reconstructing the true gas temperature from the resulting signals. Such a technique has been applied in gas turbine, rocket motor and combustion research. A new reconstruction technique based on difference equations has been developed and its effectiveness proven theoretically. The algorithms have been successfully tested and proven on experimental data from a rig that produces cyclic temperature variations. These tests highlighted that the separation of the thermocouple junctions must be very small to ensure that both sensors are subjected to the same gas temperatures. Exhaust gas temperatures were recorded by an array of thermocouples during transient operation of a high performance two-stroke engine. The results show that the increase in bandwidth arising from the dual sensor technique allowed accurate measurement of exhaust gas temperature with relatively robust thermocouples. Finally, an array of very fine thermocouples (12.5 - 50 microns) was used to measure the in-cycle temperature variation in the exhaust.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray emission from a comet was observed for the first time in 1996. One of the mechanisms believed to be contributing to this surprisingly strong emission is the interaction of highly charged solar wind ions with cometary gases. Reported herein are total absolute charge-exchange and normalized line-emission (X-ray) cross sections for collisions of high-charge state (+3 to +10) C, N, O, and Ne ions with the cometary species H2O and CO2. It is found that in several cases the double charge-exchange cross sections can be large, and in the case of C3+ they are equal to those for single charge exchange. Present results are compared to cross section values used in recent comet models. The importance of applying accurate cross sections, including double charge exchange, to obtain absolute line-emission intensities is emphasized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In gas discharges at elevated pressure, radiation-less collisional de-excitation (quenching) has a strong influence on the population of excited states. The knowledge of quenching coefficients is therefore important for plasma diagnostics and simulations. A novel time-resolved optical emission spectroscopic (OES) technique allows the measurement of quenching coefficients for emission lines of various species, particularly of noble gases, with molecular hydrogen as collision partner. The technique exploits the short electron impact excitation during the field reversal phase within the sheath region of a hydrogen capacitively coupled RF discharge at 13.56 MHz. Quenching coefficients can be determined subsequent to this excitation from the effective lifetime of the fluorescence decay at various hydrogen pressures. The measured quenching coefficients agree very well with results obtained by means of laser excitation. The time-resolved OES technique based on electron impact excitation is not limited - in contrast to laser techniques - by optical selection rules and the energy gap between the ground state and the observed excited level.