56 resultados para subjective and objective video quality assessment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of an automated system for the quality assessment of aerodrome ground lighting (AGL), in accordance with associated standards and recommendations, is presented. The system is composed of an image sensor, placed inside the cockpit of an aircraft to record images of the AGL during a normal descent to an aerodrome. A model-based methodology is used to ascertain the optimum match between a template of the AGL and the actual image data in order to calculate the position and orientation of the camera at the instant the image was acquired. The camera position and orientation data are used along with the pixel grey level for each imaged luminaire, to estimate a value for the luminous intensity of a given luminaire. This can then be compared with the expected brightness for that luminaire to ensure it is operating to the required standards. As such, a metric for the quality of the AGL pattern is determined. Experiments on real image data is presented to demonstrate the application and effectiveness of the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective

Global migration of healthcare workers places responsibility on employers to comply with legal employment rights whilst ensuring patient safety remains the central goal. We describe the pilot of a communication assessment designed for doctors who trained and communicated with patients and colleagues in a different language from that of the host country. It is unique in assessing clinical communication without assessing knowledge.

Methods

A 14-station OSCE was developed using a domain-based marking scheme, covering professional communication and English language skills (speaking, listening, reading and writing) in routine, acute and emotionally challenging contexts, with patients, carers and healthcare teams. Candidates (n = 43), non-UK trained volunteers applying to the UK Foundation Programme, were provided with relevant station information prior to the exam.

Results

The criteria for passing the test included achieving the pass score and passing 10 or more of the 14 stations. Of the 43 candidates, nine failed on the station criteria. Two failed the pass score and also the station criteria. The Cronbach's alpha coefficient was 0.866.

Conclusion

This pilot tested ‘proof of concept’ of a new domain-based communication assessment for non-UK trained doctors.

Practice implications

The test would enable employers and regulators to verify communication competence and safety in clinical contexts, independent of clinical knowledge, for doctors who trained in a language different from that of the host country.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Assessing methodological quality of primary studies is an essential component of systematic reviews. Following a systematic review which used a domain based system [United States Preventative Services Task Force (USPSTF)] to assess methodological quality, a commonly used numerical rating scale (Downs and Black) was also used to evaluate the included studies and comparisons were made between quality ratings assigned using the two different methods. Both tools were used to assess the 20 randomized and quasi-randomized controlled trials examining an exercise intervention for chronic musculoskeletal pain which were included in the review. Inter-rater reliability and levels of agreement were determined using intraclass correlation coefficients (ICC). Influence of quality on pooled effect size was examined by calculating the between group standardized mean difference (SMD).

RESULTS: Inter-rater reliability indicated at least substantial levels of agreement for the USPSTF system (ICC 0.85; 95% CI 0.66, 0.94) and Downs and Black scale (ICC 0.94; 95% CI 0.84, 0.97). Overall level of agreement between tools (ICC 0.80; 95% CI 0.57, 0.92) was also good. However, the USPSTF system identified a number of studies (n = 3/20) as "poor" due to potential risks of bias. Analysis revealed substantially greater pooled effect sizes in these studies (SMD -2.51; 95% CI -4.21, -0.82) compared to those rated as "fair" (SMD -0.45; 95% CI -0.65, -0.25) or "good" (SMD -0.38; 95% CI -0.69, -0.08).

CONCLUSIONS: In this example, use of a numerical rating scale failed to identify studies at increased risk of bias, and could have potentially led to imprecise estimates of treatment effect. Although based on a small number of included studies within an existing systematic review, we found the domain based system provided a more structured framework by which qualitative decisions concerning overall quality could be made, and was useful for detecting potential sources of bias in the available evidence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Morphological changes in the retinal vascular network are associated with future risk of many systemic and vascular diseases. However, uncertainty over the presence and nature of some of these associations exists. Analysis of data from large population based studies will help to resolve these uncertainties. The QUARTZ (QUantitative Analysis of Retinal vessel Topology and siZe) retinal image analysis system allows automated processing of large numbers of retinal images. However, an image quality assessment module is needed to achieve full automation. In this paper, we propose such an algorithm, which uses the segmented vessel map to determine the suitability of retinal images for use in the creation of vessel morphometric data suitable for epidemiological studies. This includes an effective 3-dimensional feature set and support vector machine classification. A random subset of 800 retinal images from UK Biobank (a large prospective study of 500,000 middle aged adults; where 68,151 underwent retinal imaging) was used to examine the performance of the image quality algorithm. The algorithm achieved a sensitivity of 95.33% and a specificity of 91.13% for the detection of inadequate images. The strong performance of this image quality algorithm will make rapid automated analysis of vascular morphometry feasible on the entire UK Biobank dataset (and other large retinal datasets), with minimal operator involvement, and at low cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The availability of BRAF inhibitors has given metastatic melanoma patients an effective new treatment choice and molecular testing to determine the presence or absence of a BRAF codon 600 mutation is pivotal in the clinical management of these patients. This molecular test must be performed accurately and appropriately to ensure that the patient receives the most suitable treatment in a timely manner. Laboratories have introduced such testing; however, some experience low sample throughput making it critical that an external quality assurance programme is available to help promote a high standard of testing, reporting and provide an educational aspect for BRAF molecular testing. Laboratories took part in three rounds of external quality assessment (EQA) during a 12-month period giving participants a measure of the accuracy of genotyping, clinical interpretation of the result and experience in testing a range of different samples. Formalin fixed paraffin embedded tissue sections from malignant melanoma patients were distributed to participants for BRAF molecular testing. The standard of testing was generally high but distribution of a mutation other than the most common, p.(Val600Glu), highlighted concerns with detection or reporting of the presence of rarer mutations. The main issues raised in the interpretation of the results were the importance of clear unambiguous interpretation of the result tailored to the patient and the understanding that the treatment is different from that given to other stratified medicine programmes. The variability in reporting and wide range of methodologies used indicate a continuing need for EQA in this field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A full-scale, seven-story, reinforced concrete building frame was constructed in-place at the Building Research Establishment's Cardington Laboratory, which encompassed a range of different concrete mixtures and advanced construction techniques. This provided an opportunity to assess in-place nondestructive test methods, namely the pullout test, and more specifically the Danish version, which has been known as the Lok test, on a systematic basis during the construction of the building. It was used in conjunction with both standard and temperature-matched cube specimens to assess its practicality and accuracy under site conditions. Strength correlations were determined using linear and power function regression analysis. Strength predictions from these were found to be in very good agreement with the compressive strengths of temperature-matched cube specimens. When a general correlation is used, however, estimates for compressive strength are likely to have 95% confidence limits of around '20% of the mean value of four results.