150 resultados para silicone oil


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the tamponade effect on the retina of a heavier-than-water silicone oil mixture and to compare it with the effect of silicone oil. Methods: Prospective, non-randomised, comparative pilot study. Phakic/pseudophakic patients with retinal detachment undergoing vitrectomy with Densiron 68 or silicone oil were recruited. The 'separation volume', defined as the relative volume of the space between intraocular tamponade agent and retina, was estimated using magnetic resonance imaging in both groups and compared. Results: Nine participants were included; 4 received silicone oil and 5 Densiron 68. The mean separation volume was statistically significantly larger in the silicone oil group (0.477 ± 0.419 cm ) than in the Densiron group (0.042 ± 0.013 cm ; p = 0.014). Conclusions: In this study Densiron achieved an excellent tamponade effect in the retina. © 2011 S. Karger AG, Basel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To describe endothelial changes associated with emulsified silicone oil. Methods. Report of a case. Results. A 77-year-old man had multiple and diffuse clear vesicles on the endothelium of his left eye (LE). The cornea was clear and thin. He had undergone pars plana vitrectomy and intraocular silicone oil injection 5 years before presentation. Specular microscopy revealed numerous small bubbles of emulsified silicone oil and a mild degree of endothelial damage. Conclusion. Emulsified silicone oil can adhere to the endothelium and induce an apparent droplet-like endotheliopathy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the effectiveness of diode laser trans-scleral cyclophotocoagulation (TSCPC) on intraocular pressure (IOP) in nine patients having raised IOP following use of silicone oil (SO) for retinal detachment (RD) surgery in a retrospective observational case series. Diode laser TSCPC was applied at a power setting of 1.75 to 2.5 watts, for two sec with a maximum of 30 applications. The patients were followed up for 40 to 312 weeks. The mean pre-laser IOP was 32.06 mm Hg (SD 7.32). The mean post-laser IOP at one month, three months and six months was 17.89 mm Hg (SD 8.23), 21.89 mm Hg (SD 8.16) and 21.67 mm Hg (SD 7.55) respectively. The final IOP (at the last follow-up) was 19.56 mm Hg (SD 7.85) (P=0.021). Seven of them had undergone SO removal. In our observation, effectiveness of TSCPC in long-term control of SO-induced ocular hypertension was limited as compared to short-term control of IOP.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To determine the incidence of giant retinal tear (GRT) in the United Kingdom and to provide epidemiologic data, clinical characteristics, treatment methods, and short-term outcomes in affected and fellow eyes. METHODS. Patients with a newly developed GRT (90° or greater in circumferential extent associated with posterior vitreous detachment) were identified prospectively over a 13-month period (January 2007-January 2008, inclusive) by active surveillance through the British Ophthalmic Surveillance Unit. Questionnaire-based data were obtained from reporting ophthalmologists at baseline and 12 months. RESULTS. Sixty patients (62 eyes) developed a new GRT, giving a U.K. annual incidence of 0.094 (95% CI 0.072-0.120) cases or 0.091 (95% CI 0.069-0.117) patients per 100,000. The GRTs were mostly idiopathic (54.8%), affected middle-aged (mean, 42.2 years), white British (93.3%) males (71.7%), with presenting vision worse than 20/40 in 59.7%, foveal detachment in 45.2%, and proliferative vitreoretinopathy of grade C (PVR-C) or worse in 11.3%. Treatment in most was managed by pars plana vitrectomy (93.5%) with laser retinopexy (52.5%) and silicone oil endotamponade (75.8%). Prophylactic 360° laser or cryotherapy was applied to 39.0% of the fellow eyes. At mean follow-up of 11.3 months, eventual retinal reattachment was attained in 94.7%, although only 42.1% achieved vision of =20/40. Neither GRT nor RD developed in any of the 19 nontraumatic, noniatrogenic, prophylactically treated fellow eyes. CONCLUSIONS. This study is the first population-based prospective effort to evaluate the epidemiology of GRT. Although onlya minority presented with PVR-C and high retinal reattachment rates were achieved, fewer than half had vision sufficient for driving in the GRT eye.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim - To describe a new surgical technique for foveal relocation, and to report the outcome in nine patients treated with this procedure. Methods - Nine consecutive patients with subfoveal choroidal neovascular membranes (CNVMs) secondary to age related macular degeneration underwent foveal relocation surgery by redistribution of the neurosensory retina (RNR). The technique involved induction of a retinal detachment via a single retinotomy, relocation of the fovea by 'sweeping' the retinal tissue with a retinal brush, and stabilisation of the retina in its new location using perfluorocarbon liquid peroperatively and silicone oil postoperatively. Results - In eight of nine eyes successful relocation of the fovea was achieved; in one eye the CNVM remained in a subfoveal location postoperatively. Visual acuity improved in two eyes, remained unchanged in three, and decreased in four eyes after a median follow up of 4 months (range 2.5-6 months). Complications included rupture of a foveal cyst with the development of a macular hole in one eye and epimacular membrane formation in another eye. In two eyes, macular retinal vessel closure occurred at the time of laser photocoagulation; one of these eyes later developed cystoid macular oedema and the other an epiretinal membrane. Recurrence of the CNVM was observed in one eye, but was controlled with further laser treatment. Conclusions - Foveal relocation by RNR appears to be feasible, obviating the need for extensive retinotomies or scleral shortening.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent advances in corneal graft technology, including donor tissue retrieval, storage and surgical techniques, have greatly improved the clinical outcome of corneal grafts. Despite these advances, immune mediated corneal graft rejection remains the single most important cause of corneal graft failure. Several host factors have been identified as conferring a "high risk" status to the host. These include: more than two quadrant vascularisation, with associated lymphatics, which augment the afferent and efferent arc of the immune response; herpes simplex keratitis; uveitis; silicone oil keratopathy; previous failed (rejected) grafts; "hot eyes"; young recipient age; and multiple surgical procedures at the time of grafting. Large grafts, by virtue of being closer to the host limbus, with its complement of vessels and antigen-presenting Langerhans cells, also are more susceptible to rejection. The diagnosis of graft rejection is entirely clinical and in its early stages the clinical signs could be subtle. Graft rejection is largely mediated by the major histocompatibility antigens, minor antigens and perhaps blood group ABO antigens and some cornea-specific antigens. Just as rejection is mediated by active immune mediated events, the lack of rejection (tolerance) is also sustained by active immune regulatory mechanisms. The anterior chamber associated immune deviation (ACAID) and probably, conjunctiva associated lymphoid tissue (CALT) induced mucosal tolerance, besides others, play an important role. Although graft rejection can lead to graft failure, most rejections can be readily controlled if appropriate management is commenced at the proper time. Topical steroids are the mainstay of graft rejection management. In the high-risk situations however, systemic steroids, and other immunosuppressive drugs such as cyclosporin and tacrolimus (FK506) are of proven benefit, both for treatment and prevention of rejection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A giant retinal tear (GRT) is a full-thickness neurosensory retinal break that extends circumferentially around the retina for three or more clock hours in the presence of a posteriorly detached vitreous. Its incidence in large population-based studies has been estimated as 1.5% of rhegmatogenous retinal detachments, with a significant male preponderance, and bilaterality in 12.8%. Most GRTs are idiopathic, with trauma, hereditary vitreoretinopathies and high myopia each being causative in decreasing frequency. The vast majority of GRTs are currently managed with a pars plana vitrectomy; the use of adjunctive circumferential scleral buckling is debated, but no studies have shown a clear anatomical or visual advantage with its use. Similarly, silicone oil tamponade does not influence long-term outcomes when compared with gas. Primary and final retinal reattachment rates are achieved in 88% and 95% of patients, respectively. Even when the retina remains attached, however, visual recovery may be limited. Furthermore, fellow eyes of patients with a GRT are at higher risk of developing retinal tears and retinal detachment. Prophylactic treatment under these circumstances may be considered but there is no firm evidence of its efficacy at the present time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The importance of the frying oil as a heat-transfer medium and as a source of flavor precursors for the formation of potato chip flavor was investigated. Potato slices were fried in palmolein or silicone fluid, and the volatile flavor compounds of the resulting chips were isolated onto Tenax and analyzed by gas chromatography-mass spectrometry. Although the heat-transfer coefficients of the oils did not differ significantly, their temperature profiles during frying were different, probably due to greater turbulence on placing potato slices in palmolein, leading to more efficient heat transfer. Levels of Strecker aldehydes and sulfides in chips fried in the two media were not significantly different, but levels of pyrazines were significantly higher in palmolein-fried chips. Amounts of 2,4-decadienal were also significantly higher in palmolein-fried chips, but there was no significant difference in hexanal levels between the samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxybutynin, a drug of choice in the treatment of urinary incontinence, has low oral bioavailability due to extensive first-pass metabolism. A toxic metabolite, N-desethyloxybutynin, has been linked to adverse reactions to oral oxybutynin. This study, therefore, reports on the design of an oxybutynin intravaginal ring (IVR) of reservoir design, comprising an oxybutynin silicone elastomer core encased in a non-medicated silicone sheath, manufactured by reaction injection moulding at 50oC. An unusually high initial burst release of oxybutynin (42.7 mg in 24 h) was observed in vitro with a full length core (100 mg drug loading), with subsequent non-zero order drug release. Use of fractional segment cores substantially reduced the burst effect, yielding linear cumulative drug release versus time plots from days 2 to 14. Thus, a 1/8 fractional segment core gave a 24 h burst of 11.28 mg oxybutynin and, thereafter, zero order release at the target dose of 5 mg/day over 14 days. Two oxybutynin cores, each 1/16 of full length, gave a greater release than a single 1/8 core, due to core segment end effects resulting in an increased surface area for release. The burst release was investigated by determining drug solubilities in the propan-1-ol product of elastomer condensation cure (390 mg/ml) and in the elastomer itself (13.9-20.21 mg/ml, by direct extraction and indirect thermal methods). These high oxybutynin solubilities were considered the major contributors to the burst effect. It was concluded that use of a fractional segment core would allow development of a suitable oxybutynin reservoir IVR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract There is considerable interest in developing medical devices that provide controlled delivery of biologically active agents, for example, to reduce the incidence of device-related infection. Silicone elastomers are one of the commonest biomaterials used in medical device production. However, they have a relatively high coefficient of friction and the resulting lack of lubricity can cause pain and tissue damage on device insertion and removal. Novel silicone cross-linking agents have recently been reported that produce inherently ‘self-lubricating’ silicone elastomers with very low coefficients of friction. In this study, the model antibacterial drug metronidazole has been incorporated into these self-lubricating silicone elastomers to produce a novel bioactive biomaterial. The in vitro release characteristics of the bioactive component were evaluated as a function of cross-linker composition and drug loading. Although conventional matrix-type release kinetics were observed for metronidazole from the silicone systems, it was also observed that increasing the concentration of the cross-linking agent responsible for the lubricious character (tetra(oleyloxy)silane) relative to that of the standard non-lubricious cross-linking agent (tetrapropoxysilane) produced an increase in the metronidazole flux rate by up to 65% for a specified drug loading. The results highlight the potential for developing lubricious silicone medical devices with enhanced drug release characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicone has a relatively high coefficient of friction and silicone medical devices therefore lack inherent lubricity, leading to pain on device insertion and potential tissue trauma. In this study, higher molecular weight tetra(alkoxy) silanes, particularly tetra(oleyloxy) silane, have been used as crosslinkers in the condensation cure of a hydroxy end-functionalised linear poly(dimethylsiloxane). The resulting elastomers displayed a persistent lubricous surface of oleyl alcohol, and coefficients of friction (static and dynamic) approaching zero. Chemical structures of the synthesised silanes and surface alcohol exudate were confirmed by nuclear magnetic resonance spectroscopy. Mechanical properties of the elastomers, which were chemically identical to conventionally cured systems, suggested that an 80/20 mixture of tetra(oleyloxy) silane and tetra(propoxysilane) gave the best compromise between desirable mechanical and frictional properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The silicone elastomer solubilities of a range of drugs and pharmaceutical excipients employed in the development of silicone intravaginal drug delivery rings (polyethylene glycols, norethisterone acetate, estradiol, triclosan, oleyl alcohol, oxybutynin) have been determined using dynamic mechanical analysis. The method involves measuring the concentration-dependent decrease in the storage modulus associated with the melting of the incorporated drug/excipient, and extrapolation to zero change in storage modulus. The study also demonstrates the effect of drug/excipient concentrations on the mechanical stiffness of the silicone devices at 37°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of self-lubricating silicone elastomeric biomaterials, prepared using the novel crosslinking agent tetra( oleyloxy) silane and having very low coefficients of friction, has recently been reported. In this study, the in vitro release characteristics of lubricious oleyl alcohol produced during the silicone curing reaction have been quantitatively evaluated for a range of tetra( propoxy) silane/tetra(oleyloxy) silane crosslinker compositions using a novel evaporative light scattering detection method in combination with high performance liquid chromatography. The mechanism of oleyl alcohol release was seen to deviate from a simple, matrix-controlled diffusion process and instead obeyed an anomalous transport mechanism. An explanation for the observed release behaviour has been proposed based on competitive reaction kinetics between the tetra( oleyloxy) silane and tetra( propoxy) silane substituents of the silicone crosslinking agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The controlled-release characteristics of matrix silicone intravaginal rings loaded with between 100 and 971 mg of nonoxynol-9 have been investigated with a view to developing a ring that may offer a new female-controlled method for the prevention of transmission of sexually transmitted diseases, particularly HIV. Intravaginal rings containing 253, 487 and 971 mg of nonoxynol-9 provided a daily release of 2 mg or more over the 8-day release period, the minimal amount of nonoxynol-9 considered to provide an effective vaginal concentration for the prevention of HIV. Furthermore, the maximum daily release of N9 was about 6 mg, an amount significantly smaller than that observed for other nonoxynol-9 products whose large daily doses may in fact increase the occurrence of HIV by causing epithelial damage to the vaginal tissue. The release mechanism of the liquid nonoxynol-9 from the intravaginal rings has also been investigated and compared to models describing the release of solid drugs from the rings. It has been demonstrated through release studies and surface microscopy that a drug depletion zone is not established in such liquid-loaded intravaginal ring systems, with implications for the release kinetics. (C) 2003 Elsevier B.V. All rights reserved.