This chapter describes my experiences of conducting research on commercial sex in Belfast, Northern Ireland which was conducted as part of a larger British Academy – Leverhulme Trust funded study that examined the policing and legal regulation of commercial sex in Belfast (Northern Ireland) along with three other cities: Manchester (England), Berlin (Germany) and Prague (Czech Republic). This study provided the first empirical analysis of commercial sex in the jurisdiction and was instrumental in shedding light on prevalence rates for those involved in the industry as well as providing demographic information on the age, nationality and sexual orientation of sex workers along with the sector worked in, whether on-street or off-street. In the chapter I consider my role as a researcher and highlight some of the difficulties that I experienced conducting what was seen as controversial research in the politically, socially and culturally conservative context of Northern Ireland.
Resumo:
BACKGROUND: A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter.
METHODS: Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies.
RESULTS: There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions.
CONCLUSIONS: A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.