77 resultados para precipitation and ultrasound


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective Within the framework of a health technology assessment and using an economic model, to determine the most clinically and cost effective policy of scanning and screening for fetal abnormalities in early pregnancy. Design A discrete event simulation model of 50,000 singleton pregnancies. Setting Maternity services in Scotland. Population Women during the first 24 weeks of their pregnancy. Methods The mathematical model was populated with data on uptake of screening, prevalence, detection and false positive rates for eight fetal abnormalities and with costs for ultrasound scanning and serum screening. Inclusion of abnormalities was based on the relative prevalence and clinical importance of conditions and the availability of data. Six strategies for the identification of abnormalities prenatally including combinations of first and second trimester ultrasound scanning and first and second trimester screening for chromosomal abnormalities were compared. Main outcome measures The number of abnormalities detected and missed, the number of iatrogenic losses resulting from invasive tests, the total cost of strategies and the cost per abnormality detected were compared between strategies. Results First trimester screening for chromosomal abnormalities costs more than second trimester screening but results in fewer iatrogenic losses. Strategies which include a second trimester ultrasound scan result in more abnormalities being detected and have lower costs per anomaly detected. Conclusions The preferred strategy includes both first and second trimester ultrasound scans and a first trimester screening test for chromosomal abnormalities. It has been recommended that this policy is offered to all women in Scotland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To prospectively compare clinical examination of the ankle structures with ultrasound (US) findings. Methods. In 42 children with juvenile idiopathic arthritis (JIA; 25 girls, 17 boys, mean age 11.3 yrs, range 2.3–22.3 yrs), a total of 61 swollen/painful ankles were assessed clinically and ultrasonographically. Accurate clinical examination of the entire ankle joint was performed, focusing especially on 3 regions — tibiotalar joint and medial and lateral tendons. Clinical and US findings were both scored 0–3 (normal-severe). Results. US demonstrated no signs of tibiotalar joint effusion in 14 out of 43 ankles considered clinically involved. For the medial tendons, US showed tenosynovitis in 13 ankles out of 31 thought to be clinically normal; and for the lateral tendons, of the 19 deemed to be clinically involved, less than 50% had involvement on US. Very poor agreement was observed comparing the clinical and US scores for the 3 regions: tibiotalar joint, kappa = 0.3; medial tendons, kappa = 0.24; lateral tendons, kappa = 0.25. With regard to other ankle structures, only 39% of the subtalar (talocalcaneal) joints considered clinically involved were deemed abnormal on US. Finally, of the 10 ankles with talonavicular US effusion, only 2 were considered clinically involved. Conclusion. Using US findings as the “gold standard,” clinical examination of the ankle in children with JIA was found to be inadequate in identifying the structures involved. US assessment prior to any glucocorticoid injection should be considered to improve the outcome. A prospective study comparing the outcome following clinical- versus US-guided ankle joint injection should be undertaken, to confirm our findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To evaluate agreement between clinical examination (slit lamp examination and gonioscopy) and ultrasound biomicroscopy (UBM) in characterizing various features of the anterior chamber angle and adjacent structures. Methods. Twenty-eight patients (51 eyes) with open angle glaucoma (14), closed angle glaucoma (4), narrow angle and/or plateau iris (10), who had undergone UBM between March 94 and September 95 were studied. Evaluated parameters included angle width, iris configuration and presence of angle closure. The UBMs were reviewed in a masked fashion. Results. In 87.8% of cases there was agreement (within 10 degrees) between gonioscopic and UBM estimates of angle width. In all cases with greater than 10 degrees difference (12.2%) the angle size estimated by UBM was less than that estimated clinically. Iris configuration was graded identically in 51% of cases; the majority of disagreements (76.1%) occurred in cases graded as "regular" by gonioscopy and as "steep" by UBM. Angle closure was judged to be present more frequently by UBM. Conclusions. UBM and gonioscopy do not necessarily yield identical values for angle width, iris configuration, and presence of angle closure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ObjectiveThe objective of this paper is to elucidate the role of specific cytokines in lupus (SLE) arthritis.MethodsFifty SLE and 40 RA patients had an ultrasound (US) scan of their hand as per standardized protocols. US scores were expressed per joint and as a total 'US activity' score, (sum of power Doppler (PD) and grey-scale synovial hypertrophy scores in all joints) and a total erosion score. SLE disease activity was assessed (BILAG and SELENA-SLEDAI). Plasma levels of IL-6, TNF-alpha and BLyS were measured using sandwich ELISA kits (Quantikine kits, R & D).ResultsOn the basis of the US results SLE patients were divided into three groups: erosive arthritis (n?=?20), non-erosive arthritis (n?=?18) and those with a normal US scan (n?=?12). Across the SLE groups plasma IL-6 levels correlated with CRP (p?

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Recent experimental evidence has challenged the paradigm according to which radiation traversal through the nucleus of a cell is a prerequisite for producing genetic changes or biological responses. Thus, unexposed cells in the vicinity of directly irradiated cells or recipient cells of medium from irradiated cultures can also be affected. The aim of the present study was to evaluate, by means of the medium transfer technique, whether interleukin-8 and its receptor (CXCR1) may play a role in the bystander effect after gamma irradiation of T98G cells in vitro. In fact the cell specificity in inducing the bystander effect and in receiving the secreted signals that has been described suggests that not only the ability to release the cytokines but also the receptor profiles are likely to modulate the cell responses and the final outcome. The dose and time dependence of the cytokine release into the medium, quantified using an enzyme linked immunosorbent assay, showed that radiation causes alteration in the release of interleukin-8 from exposed cells in a dose-independent but time-dependent manner. The relative receptor expression was also affected in exposed and bystander cells.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Delivering sufficient dose to tumours while sparing surrounding tissue is one of the primary challenges of radiotherapy, and in common practice this is typically achieved by using highly penetrating MV photon beams and spatially shaping dose. However, there has been a recent increase in interest in the possibility of using contrast agents with high atomic number to enhance the dose deposited in tumours when used in conjunction with kV x-rays, which see a significant increase in absorption due to the heavy element's high-photoelectric cross-section at such energies. Unfortunately, the introduction of such contrast agents significantly complicates the comparison of different source types for treatment efficacy, as the dose deposited now depends very strongly on the exact composition of the spectrum, making traditional metrics such as beam quality less valuable. To address this, a 'figure of merit' is proposed, which yields a value which enables the direct comparison of different source types for tumours at different depths inside a patient. This figure of merit is evaluated for a 15 MV LINAC source and two 150 kVp sources (both of which make use of a tungsten target, one with conventional aluminium filtration, while the other uses a more aggressive thorium filter) through analytical methods as well as numerical models, considering tissue treated with a realistic concentration and uptake ratio of gold nanoparticle contrast agents (10 mg ml(-1) concentration in 'tumour' volume, 10: 1 uptake ratio). Finally, a test case of human neck phantom is considered with a similar contrast agent to compare the abstract figure to a more realistic treatment situation. Good agreement was found both between the different approaches to calculate the figure of merit, and between the figure of merit and the effectiveness in a more realistic patient scenario. Together, these observations suggest that there is the potential for contrast-enhanced kilovoltage radiation to be a useful therapeutic tool for a number of classes of tumour on dosimetric considerations alone, and they point to the need for further research in this area.