20 resultados para measurement techniques


Relevância:

70.00% 70.00%

Publicador:

Resumo:

We introduce a method for measuring the full stress tensor in a crystal utilising the properties of individual point defects. By measuring the perturbation to the electronic states of three point defects with C 3 v symmetry in a cubic crystal, sufficient information is obtained to construct all six independent components of the symmetric stress tensor. We demonstrate the method using photoluminescence from nitrogen-vacancy colour centers in diamond. The method breaks the inverse relationship between spatial resolution and sensitivity that is inherent to existing bulk strain measurement techniques, and thus, offers a route to nanoscale strain mapping in diamond and other materials in which individual point defects can be interrogated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Silver thin films were modified using a novel plasma modification process for the development of thin-film silver-silver chloride reference electrodes. The surface, physical, and electrochemical properties of these electrodes were investigated by atomic force microscopy, thickness and resistivity measurement techniques, as well as impedance spectroscopy and potentiometry. After plasma treatment, thin-film growth was observed and the electrodes, in general, exhibited low interface impedance and a roughened surface. Evidence of a complex surface reorganization was found. Correlating plasma conditions with film properties suggested that increasing pressure and exposure duration increased species availability, therefore governing the reaction rates, while input power appeared to influence the type of surface chemical reactions. Results also indicated that Ar/Cl-2 mixtures should be employed rather than pure chlorine plasmas. (C) 2002 The Electrochemical Society.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pain expression in neonates instigated by heel-lance for blood sampling purposes was systematically described using measures of facial expression and cry and compared across sleep/waking states and sex. From gate-control theory it was hypothesized that pain behavior would vary with the ongoing functional state of the infant, rather than solely reflecting tissue insult. Awake-alert but inactive infants responded with the most facial activity, consistent with current views that infants in this state are most receptive to environmental stimulation. Infants in quiet sleep showed the least facial reaction and the longest latency to cry. Fundamental frequency of cry was not related to sleep/waking state. This suggested that findings from the cry literature on qualities of pain cry as a reflection of nervous system 'stress', in unwell newborns, do not generalize directly to healthy infants as a function of state. Sex differences were apparent in speed of response, with boys showing shorter time to cry and to display facial action following heel-lance. The findings of facial action variation across sleep/waking state were interpreted as indicating that the biological and behavioral context of pain events affects behavioral expression, even at the earliest time developmentally, before the opportunity for learned response patterns occurs. Issues raised by the study include the importance of using measurement techniques which are independent of preconceived categories of affective response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Software product development is recognised as difficult due to the intangible nature of the product, requirements elicitation, effective progress measurement, and so forth. In this paper, we describe some of the challenges of software product development and how the challenges are being met by lean management principles and techniques. Specifically, we examine lean principles and techniques that were devised by Toyota and other manufacturers over the last 50 years. Applying lean principles to software development projects has been advocated for over ten years and it will be shown that the extensive lean literature is a valuable source of ideas for software development. A case study with a software development organisation, Timberline Inc., will demonstrate that lean principles and techniques can be successfully applied to software product development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contact friction plays a critical role in all the major thermoforming processes for polymers. However, these effects are very difficult to measure in practice and, as a result, have received little scientific investigation. In this work, two independently developed test methods for the measurement of elevated temperature polymer-to-polymer contact friction are presented, and their results are compared in detail for the first time. One is based on a modified moving sled friction test, whereas the other uses a rotational rheometer. In each case, friction tests were conducted between two plug and two sheet materials. The results show that broadly similar coefficients of friction were obtained from the two test methods. The measured values were quite low (<0.3) at lower temperatures and typically were higher for polypropylene (PP) sheet than for polystyrene (PS). On approaching the glass transition temperature for PS (95°C) and the crystalline melting point for PP (165°C), the friction coefficients rose very sharply, and both test techniques became increasingly unreliable. It was concluded that despite their physical differences, both test techniques were able to capture the highly temperature sensitive nature of friction between polymer materials used in thermoforming.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many different immunochemical platforms exist for the screening of naturally occurring contaminants in food from the low cost enzyme linked immunosorbent assays (ELISA) to the expensive instruments such as optical biosensors based on the phenomenon of surface plasmon resonance (SPR). The primary aim of this study was to evaluate and compare a number of these platforms to assess their accuracy and precision when applied to naturally contaminated samples containing HT-2/T-2 mycotoxins. Other important factors considered were the speed of analysis, ease of use (sample preparation techniques and use of the equipment) and ultimately the cost implications. The three screening procedures compared included an SPR biosensor assay, a commercially available ELISA and an enzyme-linked immunomagnetic electrochemical array (ELIME array). The qualitative data for all methods demonstrated very good overall agreements with each other, however on comparison with mass spectrometry confirmatory results, the ELISA and SPR assay performed slightly better than the ELIME array, exhibiting an overall agreement of 95.8% compared to 91.7%. Currently, SPR is more costly than the other two platforms and can only be used in the laboratory whereas in theory both the ELISA and ELIME array are portable and can be used in the field, but ultimately this is dependent on the sample preparation techniques employed. Sample preparative techniques varied for all methods evaluated, the ELISA was the most simple to perform followed by that of the SPR method. The ELIME array involved an additional clean-up step thereby increasing both the time and cost of analysis. Therefore in the current format, field use would not be an option for the ELIME array. In relation to speed of analysis, the ELISA outperformed the other methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative measurement of the activity of photoactive films is an area of importance. The establishment of tests for standardisation of performance is important for efficient research but also a major milestone in achieving technology acceptance. In this paper, we compare three different techniques across a range of film samples from various sources. Furthermore, we demonstrate the potential of the dye-based approach as a quick and simple test. A series of photoactive film samples are compared for measured activity against each test. The test is shown to be capable of reproducible and quantitative activity results. The test has potential for use