57 resultados para installation
Resumo:
Effects of inappropriate installation can bias the measurements of flowmeters. For vortex flowmeters, a method is proposed to detect inappropriate installation of the flowmeter from the oscillatory signal of the vortex sensor. The method is based on assuming the process of vortex generation to be a generic, noisy, nonlinear oscillation, describable by a noisy Stuart-Landau equation, with a corresponding sensor signal that also contains higher harmonic excitations. By making use of the scaling properties of the Navier-Stokes Equation, the method was designed to be robust with respect to uncertainties in the fluid properties. The diagnostic functionality is demonstrated on measurement data. In the experiments, installation effects that lead to more than 0.5% error in the output of the flowmeter could clearly be detected. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
For Gallery Installation
Resumo:
The objective was to design a treatment that would dematerialise an above ground gas installation on the Liffey quayside while still meeting the functional requirement to ventilate the pressure reducing chamber inside. To do this we wrapped the installation in a skin of glass that allows the air to enter below the skin and to escape behind the parapet. The installation building is covered in plastic sequins and the glass is treated with alternating bands of dichroic film. The flow of air causes the sequins to shimmer reflecting spots of coloured light back onto the glass. At night a similar effect is created by lighting concealed within the outer skin. This project won a commendation in the RIAI Awards 2010, and an AAI award in 2011. It was published in New Irish Architecture 26. The British architectural historian William JR Curtis described it as ‘a beautiful understated little kiosk.’
Resumo:
This dissertation examines the emergence and development of sound installation art, an under-recognized tradition that has developed between music, architecture, and media art practices since the late 1950s. Unlike many musical works, which are concerned with organizing sounds in time, sound installations organize sounds in space; they thus necessitate new theoretical and analytical models that take into consideration the spatial situated-ness of sound. Existing discourses on “spatial sound” privilege technical descriptions of sound localization. By contrast, this dissertation examines the ways in which concepts of space are socially, culturally, and politically construed, and how spatially-organized sound works reflect and resist these different constructions. Using an interdisciplinary methodology of critical spatial analysis and critical studies in music, this dissertation explores such topics as: conceptions of acoustic space in postwar Western art music, architecture, and media theory; the development of sound installation art in relation to philosophies of everyday life and social space; the historical links between musical performance, conceptual art, and sound sculpture; the body as a site for sound installations; and sonicspatial strategies that confront politics of race and gender. Through these different investigations, this dissertation proposes an “ontopological” model for considering sound: a critical model of analysis and reception that privileges an understanding of sound in relation to ontologies of space and place.
Resumo:
Ground-source heat pump (GSHP) systems represent one of the most promising techniques for heating and cooling in buildings. These systems use the ground as a heat source/sink, allowing a better efficiency thanks to the low variations of the ground temperature along the seasons. The ground-source heat exchanger (GSHE) then becomes a key component for optimizing the overall performance of the system. Moreover, the short-term response related to the dynamic behaviour of the GSHE is a crucial aspect, especially from a regulation criteria perspective in on/off controlled GSHP systems. In this context, a novel numerical GSHE model has been developed at the Instituto de Ingeniería Energética, Universitat Politècnica de València. Based on the decoupling of the short-term and the long-term response of the GSHE, the novel model allows the use of faster and more precise models on both sides. In particular, the short-term model considered is the B2G model, developed and validated in previous research works conducted at the Instituto de Ingeniería Energética. For the long-term, the g-function model was selected, since it is a previously validated and widely used model, and presents some interesting features that are useful for its combination with the B2G model. The aim of the present paper is to describe the procedure of combining these two models in order to obtain a unique complete GSHE model for both short- and long-term simulation. The resulting model is then validated against experimental data from a real GSHP installation.
Resumo:
Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in certain harsh environments, for example, in combustion systems and engine exhausts, large wire diameters are required, and consequently the measurement bandwidth is reduced. This article discusses a software compensation technique to address the loss of high frequency fluctuations based on measurements from two thermocouples. In particular, a difference equation sDEd approach is proposed and compared with existing methods both in simulation and on experimental test rig data with constant flow velocity. It is found that the DE algorithm, combined with the use of generalized total least squares for parameter identification, provides better performance in terms of time constant estimation without any a priori assumption on the time constant ratios of the thermocouples.
Resumo:
Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in the harsh environment found in combustion systems and automotive engine exhausts, large wire diameters are required and consequently the measurement bandwidth is reduced. This paper describes two new algorithmic compensation techniques based on blind deconvolution to address this loss of high-frequency signal components using the measurements from two thermocouples. In particular, a continuous-time approach is proposed, combined with a cross-relation blind deconvolution for parameter estimation. A feature of this approach is that no a priori assumption is made about the time constant ratio of the two thermocouples. The advantages, including small estimation variance and limitations of the method, are highlighted using results from simulation and test rig studies.
Resumo:
This article discusses how the notion of performance provides impetus for the design of interactive digital environments. These environments can ultimately be regarded as user-spaces; a condition which replaces the "fixed" art-object with a configuration of interactions. Our understanding of space, as suggested by Lefevbre (2001), defines the "inhabitant" as a full participant, a user, a performer of space. What is at play when the installation artist designs environments that invite performative exploration? The issue of improvised performance in the inhabiting of installation spaces is exposed. Two interactive installations by the author and works by others in the field provide a context for discussion for discussion and analysis.
Resumo:
Received for publication October 31, 2002. Design and operation of Fe0 permeable reactive barriers (PRBs) can be improved by understanding the long-term mineralogical transformations that occur within PRBs. Changes in mineral precipitates, cementation, and corrosion of Fe0 filings within an in situ pilot-scale PRB were examined after the first 30 months of operation and compared with results of a previous study of the PRB conducted 15 months earlier using X-ray diffraction and scanning electron microscopy employing energy dispersive X-ray and backscatter electron analyses. Iron (oxy)hydroxides, aragonite, and maghemite and/or magnetite occurred throughout the cores collected 30 mo after installation. Goethite, lepidocrocite, mackinawite, aragonite, calcite, and siderite were associated with oxidized and cemented areas, while green rusts were detected in more reduced zones. Basic differences from our last detailed investigation include (i) mackinawite crystallized from amorphous FeS, (ii) aragonite transformed into calcite, (iii) akaganeite transformed to goethite and lepidocrocite, (iv) iron (oxy)hydroxides and calcium and iron carbonate minerals increased, (v) cementation was greater in the more recent study, and (vi) oxidation, corrosion, and disintegration of Fe0 filings were greater, especially in cemented areas, in the more recent study. If the degree of corrosion and cementation that was observed from 15 to 30 mo after installation continues, certain portions of the PRB (i.e., up-gradient entrance of the ground water to the Fe0 section of the PRB) may last less than five more years, thus reducing the effectiveness of the PRB to mitigate contaminants. Abbreviations: EDX, energy dispersive X-ray • Fe0, zerovalent iron • PRB, permeable reactive barrier • SEM, scanning electron microscopy • XRD, X-ray diffraction