8 resultados para infinito Cantor numeri transfiniti


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We examined the role of common genetic variation in schizophrenia in a genome-wide association study of substantial size: a stage 1 discovery sample of 21,856 individuals of European ancestry and a stage 2 replication sample of 29,839 independent subjects. The combined stage 1 and 2 analysis yielded genome-wide significant associations with schizophrenia for seven loci, five of which are new (1p21.3, 2q32.3, 8p23.2, 8q21.3 and 10q24.32-q24.33) and two of which have been previously implicated (6p21.32-p22.1 and 18q21.2). The strongest new finding (P = 1.6 x 10(-11)) was with rs1625579 within an intron of a putative primary transcript for MIR137 (microRNA 137), a known regulator of neuronal development. Four other schizophrenia loci achieving genome-wide significance contain predicted targets of MIR137, suggesting MIR137-mediated dysregulation as a previously unknown etiologic mechanism in schizophrenia. In a joint analysis with a bipolar disorder sample (16,374 affected individuals and 14,044 controls), three loci reached genome-wide significance: CACNA1C (rs4765905, P = 7.0 x 10(-9)), ANK3 (rs10994359, P = 2.5 x 10(-8)) and the ITIH3-ITIH4 region (rs2239547, P = 7.8 x 10(-9)).

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims. To evaluate the effect of acute elevation of intraocular pressure (IOP) on optic disc cupping. Methods. 10 emmetropic and 10 myopic volunteers were included in this study. The cup area (CA) and cup volume (CV) of the optic disc were determined with the Heidelberg retina tomograph (HRT). After baseline determinations, a suction cup was used to increase the intraocular pressure (IOP) to 20-25 mmHg above the baseline and HRT images were obtained. Results. Baseline IOP was 13.5 (SD 1.3) mmHg and 12.6 (2.6) mmHg in the emmetropic and myopic groups, respectively. The IOP was elevated to 35.4 (3.3) mmHg and 34.4 (2.5) mmHg in the emmetropic and myopic groups, respectively. When compared with their baseline values, the cupping variables (CA and CV) were significantly increased (p <0.05) during the suction treatment in both emmetropic and myopic subjects. Conclusion. There was a significant enlargement in the optic disc cupping during the artificial increment of intraocular pressure in both emmetropic and myopic eyes. In non-glaucomatous eyes the optic nerve head has a partially dynamic topography dependent upon the level of IOP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To study the effect of topical dorzolamide on retinal sensitivity in normal subjects. Methods. 20 normal subjects were prospectively randomized in a two period crossover study. Baseline threshold perimetry (HVF, program 24-2, Statpac analysis) was obtained. The study eye was randomly chosen and then was randomly assigned to receive either dorzolamide 2% or placebo one hour before repeat HVF. After at least two weeks washout the same eye was given the opposite drop one hour prior to repeat HVF. Global indices were compared using a paired T-test. Results. AFTER PLACEBO AFTER DORZOLAMIDE P-VALUE (mean±SD) (mean±SD) MD 0.12±1.4 0.16±1.4 0.82 PSD 1.83±0.6 1.66±0.4 0.04 SF 1.28±0.4 1.24±0.2 0.73 CPSD 1.05±0.9 0.84±0.6 0.35 Conclusion. In this population, topical dorzolamide had little effect on visual function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare the reproducibility of optic disk measurements provided by an image analyzer and a scanning laser tomograph. Methods: Ten images of the same eye of 10 normal volunteers were taken with the Heidelberg Retina Tomograph and with the Topcon ImageNet. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were used to evaluate the reproducibility of the measurements. Results: Eleven parameters were analyzed with the Topcon ImageNet. Six parameters (55%) had ICC greater than 90%. Four parameters (36%) had CV less than 10%. Twelve parameters were evaluated with the Heidelberg Retina Tomograph. Nine parameters (75%) had ICC over 90%. Nine parameters (75%) had CV less than 10%. Conclusion: Both systems provided reproducible data. The optic disk parameters provided by the Heidelberg Retina Tomograph had a better reproducibility than those obtained from the Topcon ImageNet.