36 resultados para glass-ionomer-resin composite hybrid material


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of this study were to determine the fracture toughness of adhesive interfaces between dentine and clinically relevant, thin layers of dental luting cements. Cements tested included a conventional glass-ionomer, F (Fuji I), a resin-modified glass-ionomer, FP (Fuji Plus) and a compomer cement, D (DyractCem). Ten miniature short-bar chevron notch specimens were manufactured for each cement, each comprising a 40 µm thick chevron of lute, between two 1.5 mm thick blocks of bovine dentine, encased in resin composite. The interfacial KIC results (MN/m3/2) were median (range): F; 0.152 (0.14-0.16), FP; 0.306 (0.27-0.37), D; 0.351 (0.31-0.37). Non-parametric statistical analysis showed that the fracture toughness of F was significantly lower (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lightning strike is one of the challenges that the aerospace industry is facing in an effort to increase the percentage of composite materials used in aircraft structures. Lightning strike damage is due to high orthotropic electric resistivity of the composite panels, which leads to high thermal loads that cause decomposition of the epoxy and delimitations of the laminates. Yet, experimental testing of lightning strike on aircraft panels is expensive due to the large number of design parameters that can control the inflicted damage. A coupled thermal-electrical finite element analysis is used to investigate the design variables space that can affect lightning strike damage on epoxy/graphite composite panels. The contribution of this study is modeling the composite panels’ material properties as temperature dependent, which was excluded by other researchers. A number of practical solutions to minimize the damage effect are proposed. Two set of experimental results are used to verify the numerical ones. One experimental set for plain composite panel, and second one for composite panels with joints

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this research we investigate the performance of drilling process in carbon fibre reinforced composite (CFC) material, titanium alloy and the hybrid stack of these two materials, using coated carbide drill bit. We study the effect of the process parameters such as the feed rate and speed on the induced forces and torques, also on the wear of drill and surface roughness of the holes. In the composite material the percentage of surface damage in both drilling CFC on its own and drilling in stack form is estimated. Also, the effect of worn drill on the surface damage is identified. In the titanium, the burr formation in stack and non-stack form is investigated. The wear of the drill results in increased forces and torques required for drilling. This increases the surface delaminations substantially at the entrance in drilling of CFC. However, the surface roughness of the holes reduces with the wear of the drill in CFC drilling. Also, the surface delamination and surface roughness of the holes in the CFC whilst drilled in hybrid form reduces significantly. This is despite the increase of the forces and torques required in drilling CFC in stack form. Copyright © 2012 Inderscience Enterprises Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To use profilometry to assess the margin surface profile of all-ceramic crowns (ACC’s) at try-in and 1-week after cementation with dual-cured resin (DC, RelyX ARC, 3 M ESPE, St. Paul, MN, USA), self-adhesive dual-cured resin (SADC, RelyX Unicem, 3 M ESPE), light-cured resin (LC, RelyX Veneer, 3 M ESPE) or chemically cured resin-modified glass ionomer (RMGI, RelyX Luting Plus, 3 M ESPE) luting cement. Methods: Forty, sound, extracted, human, premolar teeth underwent a standardised preparation for ACC’s. IPS Empress (Ivoclar-Vivadent, Liechtenstein) crowns of standard dimensions were fabricated and 10 luted with each cement and stored in water for 7 days. Three groups of serial profiles were taken, the first of the tooth preparation, the second of the crown margins at try-in and lastly of the crown margins after cementation and 7 days water storage. Results: There were no significant differences in the crown margin surface profile between the four cement groups at try-in. The change in crown margin position between try-in and post-cementation was significantly greater for DC than for LC and RMGI. SADC was not significantly different to the other cements. There were no significant differences in the crown margin extensions between the four cement groups, however most of the IPS Empress ACC’s in this study were underextended but this was not statistically significant. Conclusions: IPS Empress ACC’s seated more fully with LC and RMGI than with DC cement

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Co-assembly of an inorganic–organic hybrid material through the combination of supramolecular organogel self-assembly, phase partitioning of a conjugated polymer (CP) and transcription of an inorganic oxide leads to a hybrid material with structured domains of organogel, CP and silica within tube and rod microstructures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Older dentate adults are a high caries risk group who could potentially benefit from the use of the atraumatic restorative treatment (ART). This study aimed to compare the survival of ART and a conventional restorative technique (CT) using rotary instruments and a resin-modified glass-ionomer for restoring carious lesions as part of a preventive and restorative programme for older adults after 2 years.

METHODS: In this randomised controlled clinical trial, 99 independently living adults (65-90 years) with carious lesions were randomly allocated to receive either ART or conventional restorations. The survival of restorations was assessed by an independent and blinded examiner 6 months, 1 year and 2 years after restoration placement.

RESULTS: Ninety-six (67.6%) and 121 (76.6%) restorations were assessed in the ART and CT groups, respectively, after 2 years. The cumulative restoration survival percentages after 2 years were 85.4% in the ART and 90.9% in the CT group. No statistically significant between group differences were detected (p=0.2050, logistic regression analysis).

CONCLUSIONS: In terms of restoration survival, ART was as effective as a conventional restorative approach to treat older adults after 2 years. This technique could be a useful tool to provide dental care for older adults particularly in the non-clinical setting. (Trial Registration number: ISRCTN 76299321).

CLINICAL SIGNIFICANCE: The results of this study show that ART presented survival rates similar to conventional restorations in older adults. ART appears to be a cost-effective way to provide dental care to elderly patients, particularly in out of surgery facilities, such as nursing homes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Caries experience is high in the elderly, and barriers to care for older adults include fear and cost. Access to care is especially problematic in the case of frail and homebound elderly. Objective: to compare the survival of restorations placed using Atraumatic Restorative Treatment (ART) and a conventional technique using rotary instruments and a resin-modified glass-ionomer (CT) to treat carious lesions in older patients. Methods: In this randomised clinical trial, 99 independently living adults (65-90 yrs) with carious lesions were recruited from a geriatric day hospital and a community centre and randomly allocated to receive either ART or conventional restorations. They received tailored oral hygiene instructions and scaling and polishing of teeth prior to restoration placement. The survival of restorations was assessed 6, 12 and 24 months after restoration placement by an independent examiner. Results: Ninety-nine patients participated in the trial, 46 males and 53 females, with a mean age of 73.2 (SD: 6.8). In total, 300 restorations were placed, 142 ART in 51 patients and 158 conventional restorations in 48 patients, with an average of 2.8 ART (SD: 1.83) and 3.2 conventional (SD: 2.62) restorations placed per patient. After 2 years, 88 ART and 117 conventional restorations were assessed. The restoration survival percentages were 93.1% and 94%, respectively. Conclusion: ART was found to be as effective as a conventional restorative approach to treat older adults after 2 years and could be a useful tool to provide dental care for older dentate adults.