19 resultados para flow electrolytic reactor
Resumo:
The H+NO2 titration scheme for the determination of atomic hydrogen densities within a microwave excited flow tube reactor has been investigated by laser-induced fluorescence spectroscopy in the vacuum UV. Absolute hydrogen densities are determined on the basis of calibration by Rayleigh scattering from argon. The measurement is performed at a gas mixture containing 0.5% of D2 added to the main gas H2. The ground state density of the hydrogen atoms generated in the flow tube reactor was inferred from the fluorescence radiation of the spectrally shifted optically thin D-Lyman-a transition.
Resumo:
The present work is focused on the demonstration of the advantages of miniaturized reactor systems which are essential for processes where potential for considerable heat transfer intensification exists as well as for kinetic studies of highly exothermic reactions at near-isothermal conditions. The heat transfer characteristics of four different cross-flow designs of a microstructured reactor/heat-exchanger (MRHE) were studied by CFD simulation using ammonia oxidation on a platinum catalyst as a model reaction. An appropriate distribution of the nitrogen flow used as a coolant can decrease drastically the axial temperature gradient in the reaction channels. In case of a microreactor made of a highly conductive material, the temperature non-uniformity in the reactor is strongly dependent on the distance between the reaction and cooling channels. Appropriate design of a single periodic reactor/heat-exchanger unit, combined with a non-uniform inlet coolant distribution, reduces the temperature gradients in the complete reactor to less than 4degreesC, even at conditions corresponding to an adiabatic temperature rise of about 1400degreesC, which are generally not accessible in conventional reactors because of the danger of runaway reactions. To obtain the required coolant flow distribution, an optimization study was performed to acquire the particular geometry of the inlet and outlet chambers in the microreactor/heat-exchanger. The predicted temperature profiles are in good agreement with experimental data from temperature sensors located along the reactant and coolant flows. The results demonstrate the clear potential of microstructured devices as reliable instruments for kinetic research as well as for proper heat management in the case of highly exothermic reactions. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Gas-liquid processing in microreactors remains mostly restricted to the laboratory scale due to the complexity and expenditure needed for an adequate numbering-up with a uniform flow distribution. Here, the numbering-up is presented for multi-phase (gas-liquid) flow in microreactor suitable for a production capacity of kg/h. Based on the barrier channels concept, the barrier-based micro/milli reactor (BMMR) is designed and fabricated to deliver flow non-uniformity of less than 10%. The BMMR consists of eight parallel channels all operated in the Taylor flow regime and with a liquid flow rate up to 150. mL/min. The quality of the flow distribution is reported by studying two aspects. The first aspect is the influence of different viscosities, surface tensions and flow rates. The second aspect is the influence of modularity by testing three different reaction channels type: (1) square channels fabricated in a stainless steel plate, (2) square channels fabricated in a glass plate, and (3) circular channels (capillaries) made of stainless steel. Additionally, the BMMR is compared to that of a single channel regard the slug and bubble lengths and bubble generation frequency. The results pave the ground for bringing multi-phase flow in microreactor one step closer for large scale production via numbering-up. © 2012 Elsevier B.V.
Resumo:
This paper reports the detailed description and validation of a fully automated, computer controlled analytical method to spatially probe the gas composition and thermal characteristics in packed bed systems. As an exemplar, we have examined a heterogeneously catalysed gas phase reaction within the bed of a powdered oxide supported metal catalyst. The design of the gas sampling and the temperature recording systems are disclosed. A stationary capillary with holes drilled in its wall and a moveable reactor coupled with a mass spectrometer are used to enable sampling and analysis. This method has been designed to limit the invasiveness of the probe on the reactor by using the smallest combination of thermocouple and capillary which can be employed practically. An 80 mu m (O.D.) thermocouple has been inserted in a 250 mu m (O.D.) capillary. The thermocouple is aligned with the sampling holes to enable both the gas composition and temperature profiles to be simultaneously measured at equivalent spatially resolved positions. This analysis technique has been validated by studying CO oxidation over a 1% Pt/Al2O3 catalyst and the spatial resolution profiles of chemical species concentrations and temperature as a function of the axial position within the catalyst bed are reported.
Resumo:
The water treatment capability of a novel photocatalytic slurry reactor was investigated using methylene blue (MB) as a model pollutant in an aqueous suspension. A pellet TiO 2 catalyst was employed and this freed the system from the need of filtration of catalyst following photocatalysis. This configuration combines the high surface area contact of catalyst with pollutant of the slurry reactor and also offers a high illumination of catalyst by its unique array of weir-like baffles. In this work, the batch adsorption of MB from aqueous solution (10μM) onto the TiO 2 catalyst was studied, adsorption isotherms and kinetics were determined from the experimental data. Complete degradation of MB was achieved within 60 min illumination with various loadings of catalyst (30-200 g L -1). A modest catalyst loading (30 g L -1) achieved 98% degradation within 60 min of irradiation. Experimental results indicate that this novel reactor configuration has a high effective mass transfer rate and UV light penetration characteristics.
Resumo:
Taste and odour compounds, especially geosmin (GSM) and 2-methylisoborneol (2-MIB), cause major problems in both drinking water and aquaculture industries world-wide. Aquaculture in particular has experienced significant financial losses due to the accumulation of taint compounds prior to harvest resulting in consumer rejection. UV-TiO2 photocatalysis has been demonstrated to remove GSM and 2-MIB at laboratory scale but the development of a continuous flow reactor suitable for use in water treatment has not been investigated. In this study, a pilot packed bed photocatalytic reactor was developed and evaluated for water treatment with both laboratory and naturally tainted samples. A significant reduction of both 2-MIB and GSM was achieved in both trials using the packed bed reactor unit. With the laboratory spiked water (100ngL-1 of each compound added prior to treatment), detectable levels were reduced by up to 97% after a single pass through the unit. When the reactor was used to treat water in a fish farm where both compounds were being produced in situ (2-MIB: 19ngL-1 and GSM: 14ngL-1) a reduction of almost 90% in taint compounds was achieved. These very encouraging promising results demonstrate the potential of this UV-TiO2 photocatalytic reactor for water treatment in fish rearing systems and other applications.
Resumo:
A dielectric barrier discharge (DBD) generated by flowing helium between the parallel-plate electrodes of an open air reactor has been characterized using time resolved optical and electrical measurements. A sinusoidal voltage of up to 5 kV (peak to peak) of frequencies from 3 to 50 kHz has been applied to the discharge electrodes. The helium flow rate is varied up to 10 litre min(-1). The adjustment of flow rate allows the creation of uniform DBDs with optimized input power equal to 120 +/- 10 mW cm(-3). At flow rates from 4 to 6 litre min(-1) a uniform DBD is obtained. The maxima in the line intensities of N-2(+) and helium at 391.4 nm and 706.5 nm, respectively, 2 under those conditions indicate the importance of helium metastables and He-2(+) in sustaining such a discharge. The power efficiency and discharge 2 current show maxima when the DBD In He/air is uniform. The gas temperature during the discharge has been measured as 360 +/- 20 K.
Resumo:
The hydroformylation of 1-octene under continuous flow conditions is described. The system involves dissolving the catalyst, made in situ from [ Rh(acac)(CO)(2)] (acacH = 2,4- pentanedione) and [RMIM][TPPMS] ( RMIM = 1-propyl (Pr), 1-pentyl (Pn) or 1-octyl (O)-3-methyl imidazolium, TPPMS = Ph2P(3-C6H4SO3)), in a mixture of nonanal and 1-octene and passing the substrate, 1-octene, together with CO and H-2 through the system dissolved in supercritical CO2 (scCO(2)). [PrMIM][TPPMS] is poorly soluble in the medium so heavy rhodium leaching (as complexes not containing phosphine) occurs in the early part of the reaction. [PnMIM][ PPMS] affords good rates at relatively low catalyst loadings and relatively low overall pressure (125 bar) with rhodium losses <1 ppm, but the catalyst precipitates at higher catalyst loadings, leading to lower reaction rates. [OMIM][ TPPMS] is the most soluble ligand and promotes high reaction rates, although preliminary experiments suggested that rhodium leaching was high at 5-10 ppm. Optimisation aimed at balancing flows so that the level within the reactor remained constant involved a reactor set up based around a reactor fitted with a sight glass and sparging stirrer with the CO2 being fed by a cooled head HPLC pump, 1-octene by a standard HPLC pump and CO/H-2 through a mass flow controller. The pressure was controlled by a back pressure regulator. Using this set up, [OMIM][ TPPMS] as the ligand and a total pressure of 140 bar, it was possible to control the level within the reactor and obtain a turnover frequency of ca. 180 h(-1). Rhodium losses in the optimised system were 100 ppb. Transport studies showed that 1-octene is preferentially transported over the aldehydes at all pressures, although the difference in mol fraction in the mobile phase was less at lower pressures. Nonanal in the mobile phase suppresses the extraction of 1-octene to some extent, so it is better to operate at high conversion and low pressure to optimise the extraction of the products relative to the substrate. CO and H2 in the mobile phase also suppress the extraction effciency by as much as 80%.
Resumo:
Contemporary medical science is reliant upon the rational selection and utilization of devices, and therefore, an increasing need has developed for in vitro systems aimed at replicating the conditions to which urological devices will be subjected to during their use in vivo. We report the development and validation of a novel continuous flow encrustation model based on the commercially available CDC biofilm reactor. Proteus mirabilis-induced encrustation formation on test biomaterial sections under varying experimental parameters was analyzed by X-ray diffraction, infrared- and Raman spectroscopy and by scanning electron microscopy. The model system produced encrusted deposits similar to those observed in archived clinical samples. Results obtained for the system are highly reproducible with encrustation being rapidly deposited on test biomaterial sections. This model will have utility in the rapid screening of encrustation behavior of biomaterials for use in urological applications. (C) 2010 Wiley Periodicals. Inc. J Biomed Mater Res Part B: Appl Biomater 93B: 128-140, 2010
Resumo:
Precise control over the interfacial area of aqueous and organic slugs in segmented flow in a microchannel reactor provides an attractive means to optimize the yield and productivity of a phase-transfer-catalyzed reaction. Herein, we report the selective alkylation of phenylacetonitrile to the monoalkylated product in a microchannel of 250-mu m internal diameter operated in a continuous and solvent-free manner in the slug-flow regime. The conversion of phenylacetonitrile increased from 40% to 99% as a result of a 97% larger slug surface-to-volume ratio when the volumetric aqueous-to-organic phase flow ratio was raised from 1.0 to 6.1 at the same residence time. The larger surface-to-volume ratio significantly promoted catalyst phase transfer but decreased selectivity because of the simultaneous increase of the rate of the consecutive reaction to the dialkylated product. There exists all Optimum flow ratio with a maximum productivity. Conversion and selectivity in the microchannel reactor were both found to be significantly larger than in a stirred reactor.
Resumo:
Single-phase microreactors and micro-heat-exchangers have been widely used in industrial and scientific applications over the last decade. In several cases, operation of microreactors has shown that their expected efficiency cannot be reached either due to non-uniform distribution of reactants between different channels or due to flow maldistribution between individual microreactors working in parallel. The latter problem can result in substantial temperature deviations between different microreactors resulting in thermal run away which could arise from an exothermicreaction. Thus advances in the understanding of heat transfer and fluid flow distribution continue to be crucial in achieving improved performance, efficiency and safety in microstructured reactors used for different applications. This paper presents a review of the experimental and numerical results on fluid flow distribution, heat transfer and combination thereof, available in the open literature. Heat transfer in microchannels can be suitably described by standard theory and correlations, but scaling effects (entrance effects, conjugate heat transfer, viscous heating, and temperature-dependent properties) have often to be accounted for in microsystems. Experiments with single channels are in good agreement with predictions from the published correlations. The accuracy of multichannel experiments is lower due to flow maldistribution. Special attention is devoted to theoretical and experimental studies on the effect of a flow maldistribution on the thermal and conversion response of catalytic microreactors. There view concludes with a set of design recommendations aimed at improving the reactor performance. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The capillary micro reactor, with four stable operating flow patterns and a throughput range from grams per hour to kilograms per hour, presents an attractive alternative to chip-based and microstructured reactors for laboratory- and pilot-scale applications. In this article, results for the extraction of 2-butanol from toluene under different flow patterns in a water/toluene flow in long capillary microreactors are presented. The effects of the capillary length (0.4-2.2 m), flow rate (0.1-12 mL/min), and aqueous-to-organic volumetric flow ratio (0.25-9) on the slug, bubbly, parallel, and annular flow hydrodynamics were investigated. Weber-number-dependent flow maps were composed for capillary lengths of 0.4 and 2 m that were used to interpret the flow pattern formation in terms of surface tension and inertia forces. When the capillary length was decreased from 2 to 0.4 m, a transition from annular to parallel flow was observed. The capillary length had little influence on slug and bubbly flows. The flow patterns were evaluated in terms of stability, surface-to-volume ratio, throughput, and extraction efficiency. Slug and bubbly flow operations yielded 100% thermodynamic extraction efficiency, and increasing the aqueous-to-organic volumetric ratio to 9 allowed for 99% 2-butanol extraction. The parallel and annular flow operating windows were limited by the capillary length, thus yielding maximum 2-butanol extractions of 30% and 47% for parallel and annular flows, respectively.
Resumo:
The activity of a 5-wt% Cu/CeO2-x catalyst during preferential CO oxidation in hydrogen-rich gas mixtures was studied in a microchannel reactor. The CO concentration dropped from 1 vol.% to 10 ppm at a selectivity of 60%, at a temperature of 190 degrees C, and a weight hour space velocity (WHSV) of 55,000 cm(3) g(-1) h(-1). Both the CO concentration and the temperature increased when the WHSV was increased from 50,000 to 500,000 cm(3) g(-1) h(-1). An increase of the O-2 concentration from a 1.2 to 3 fold excess reduced the CO concentration to 10 ppm in a broad temperature interval of 50 degrees C at WHSVs up to 275,000 cm(3) g(-1) h(-1). The preferential CO oxidation could be carried out at higher flow rates and at higher selectivities in the microchannel reactor compared to a fixed-bed flow reactor. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A systematic computational fluid dynamics (CFD) approach has been applied to design the geometry of the channels of a three-dimensional (thick-walled) screen comprising upstream and downstream sets of elongated channels positioned at an angle of 90 degrees with respect to each other. Such a geometry of the thick-wall screen can effectively drop the ratio of the maximum flow velocity to mean flow velocity below 1.005 in a downstream microstructured reactor at low Reynolds numbers. In this approach the problem of flow equalization reduces to that of flow equalization in the first and second downstream channels of the thick-walled screen. In turn, this requires flow equalization in the corresponding cross-sections of the upstream channels. The validity of the proposed design method was assessed through a case study. The effect of different design parameters on the flow non-uniformity in the downstream channels has been established. The design equation is proposed to calculate the optimum values of the screen parameters. The CFD results on flow distribution were experimentally validated by Laser Doppler Anemometry measurements in the range of Reynolds numbers from 6 to 113. The measured flow non-uniformity in the separate reactor channels was below 2%.