5 resultados para cost per kg carcass


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: Prevention of cardiovascular disease and heart failure (HF) in a cost-effective manner is a public health goal. This work aims to assess the cost-effectiveness of the St Vincent's Screening TO Prevent Heart Failure (STOP-HF) intervention.

METHODS AND RESULTS: This is a substudy of 1054 participants with cardiovascular risk factors [median age 65.8 years, interquartile range (IQR) 57.8:72.4, with 4.3 years, IQR 3.4:5.2, follow-up]. Annual natriuretic peptide-based screening was performed, with collaborative cardiovascular care between specialist physicians and general practitioners provided to patients with BNP levels >50 pg/mL. Analysis of cost per case prevented and cost-effectiveness per quality-adjusted life year (QALY) gained was performed. The primary clinical endpoint of LV dysfunction (LVD) with or without HF was reduced in intervention patients [odds ratio (OR) 0.60; 95% confidence interval (CI) 0.38-0.94; P = 0.026]. There were 157 deaths and/or emergency hospitalizations for major adverse cardiac events (MACE) in the control group vs. 102 in the intervention group (OR 0.68; 95% CI 0.49-0.93; P = 0.01). The cost per case of LVD/HF prevented was €9683 (sensitivity range -€843 to €20 210), whereas the cost per MACE prevented was €3471 (sensitivity range -€302 to €7245). Cardiovascular hospitalization savings offset increased outpatient and primary care costs. The cost per QALY gain was €1104 and the intervention has an 88% probability of being cost-effective at a willingness to pay threshold of €30 000.

CONCLUSION: Among patients with cardiovascular risk factors, natriuretic peptide-based screening and collaborative care reduced LVD, HF, and MACE, and has a high probability of being cost-effective.

TRIAL REGISTRATION: NCT00921960.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Sepsis can lead to multiple organ failure and death. Timely and appropriate treatment can reduce in-hospital mortality and morbidity. Objectives: To determine the clinical effectiveness and cost-effectiveness of three tests [LightCycler SeptiFast Test MGRADE® (Roche Diagnostics, Risch-Rotkreuz, Switzerland); SepsiTest™ (Molzym Molecular Diagnostics, Bremen, Germany); and the IRIDICA BAC BSI assay (Abbott Diagnostics, Lake Forest, IL, USA)] for the rapid identification of bloodstream bacteria and fungi in patients with suspected sepsis compared with standard practice (blood culture with or without matrix-absorbed laser desorption/ionisation time-offlight mass spectrometry). Data sources: Thirteen electronic databases (including MEDLINE, EMBASE and The Cochrane Library) were searched from January 2006 to May 2015 and supplemented by hand-searching relevant articles. Review methods: A systematic review and meta-analysis of effectiveness studies were conducted. A review of published economic analyses was undertaken and a de novo health economic model was constructed. A decision tree was used to estimate the costs and quality-adjusted life-years (QALYs) associated with each test; all other parameters were estimated from published sources. The model was populated with evidence from the systematic review or individual studies, if this was considered more appropriate (base case 1). In a secondary analysis, estimates (based on experience and opinion) from seven clinicians regarding the benefits of earlier test results were sought (base case 2). A NHS and Personal Social Services perspective was taken, and costs and benefits were discounted at 3.5% per annum. Scenario analyses were used to assess uncertainty. Results: For the review of diagnostic test accuracy, 62 studies of varying methodological quality were included. A meta-analysis of 54 studies comparing SeptiFast with blood culture found that SeptiFast had an estimated summary specificity of 0.86 [95% credible interval (CrI) 0.84 to 0.89] and sensitivity of 0.65 (95% CrI 0.60 to 0.71). Four studies comparing SepsiTest with blood culture found that SepsiTest had an estimated summary specificity of 0.86 (95% CrI 0.78 to 0.92) and sensitivity of 0.48 (95% CrI 0.21 to 0.74), and four studies comparing IRIDICA with blood culture found that IRIDICA had an estimated summary specificity of 0.84 (95% CrI 0.71 to 0.92) and sensitivity of 0.81 (95% CrI 0.69 to 0.90). Owing to the deficiencies in study quality for all interventions, diagnostic accuracy data should be treated with caution. No randomised clinical trial evidence was identified that indicated that any of the tests significantly improved key patient outcomes, such as mortality or duration in an intensive care unit or hospital. Base case 1 estimated that none of the three tests provided a benefit to patients compared with standard practice and thus all tests were dominated. In contrast, in base case 2 it was estimated that all cost per QALY-gained values were below £20,000; the IRIDICA BAC BSI assay had the highest estimated incremental net benefit, but results from base case 2 should be treated with caution as these are not evidence based. Limitations: Robust data to accurately assess the clinical effectiveness and cost-effectiveness of the interventions are currently unavailable. Conclusions: The clinical effectiveness and cost-effectiveness of the interventions cannot be reliably determined with the current evidence base. Appropriate studies, which allow information from the tests to be implemented in clinical practice, are required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the design, construction and commissioning of LOTUS; a simple, low-cost long-slit spectrograph for the Liverpool Telescope. The design is optimized for near-UV and visible wavelengths and uses all transmitting optics. It exploits the instrument focal plane field curvature to partially correct axial chromatic aberration. A stepped slit provides narrow (2.5x95 arcsec) and wide (5x25 arcsec) options that are optimized for spectral resolution and flux calibration respectively. On sky testing shows a wavelength range of 3200-6300 Angstroms with a peak system throughput (including detector quantum efficiency) of 15 per cent and wavelength dependant spectral resolution of R=225-430. By repeated observations of the symbiotic emission line star AG Peg we demonstrate the wavelength stability of the system is less than 2 Angstroms rms and is limited by the positioning of the object in the slit. The spectrograph is now in routine operation monitoring the activity of comet 67P/Churyumov-Gerasimenko during its current post-perihelion apparition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background
Increasing physical activity in the workplace can provide employee physical and mental health benefits, and employer economic benefits through reduced absenteeism and increased productivity. The workplace is an opportune setting to encourage habitual activity. However, there is limited evidence on effective behaviour change interventions that lead to maintained physical activity. This study aims to address this gap and help build the necessary evidence base for effective, and cost-effective, workplace interventions

Methods/design
This cluster randomised control trial will recruit 776 office-based employees from public sector organisations in Belfast and Lisburn city centres, Northern Ireland. Participants will be randomly allocated by cluster to either the Intervention Group or Control Group (waiting list control). The 6-month intervention consists of rewards (retail vouchers, based on similar principles to high street loyalty cards), feedback and other evidence-based behaviour change techniques. Sensors situated in the vicinity of participating workplaces will promote and monitor minutes of physical activity undertaken by participants. Both groups will complete all outcome measures. The primary outcome is steps per day recorded using a pedometer (Yamax Digiwalker CW-701) for 7 consecutive days at baseline, 6, 12 and 18 months. Secondary outcomes include health, mental wellbeing, quality of life, work absenteeism and presenteeism, and use of healthcare resources. Process measures will assess intervention “dose”, website usage, and intervention fidelity. An economic evaluation will be conducted from the National Health Service, employer and retailer perspective using both a cost-utility and cost-effectiveness framework. The inclusion of a discrete choice experiment will further generate values for a cost-benefit analysis. Participant focus groups will explore who the intervention worked for and why, and interviews with retailers will elucidate their views on the sustainability of a public health focused loyalty card scheme.

Discussion
The study is designed to maximise the potential for roll-out in similar settings, by engaging the public sector and business community in designing and delivering the intervention. We have developed a sustainable business model using a ‘points’ based loyalty platform, whereby local businesses ‘sponsor’ the incentive (retail vouchers) in return for increased footfall to their business.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the cost-effectiveness of adding zoledronic acid or strontium-89 to standard docetaxel chemotherapy for patients with castrate-refractory prostate cancer (CRPC).

PATIENTS AND METHODS: Data on resource use and quality of life for 707 patients collected prospectively in the TRAPEZE 2 × 2 factorial randomised trial (ISRCTN 12808747) were used to assess the cost-effectiveness of i) zoledronic acid versus no zoledronic acid (ZA vs. no ZA), and ii) strontium-89 versus no strontium-89 (Sr89 vs. no Sr89). Costs were estimated from the perspective of the National Health Service in the UK and included expenditures for trial treatments, concomitant medications, and use of related hospital and primary care services. Quality-adjusted life-years (QALYs) were calculated according to patients' responses to the generic EuroQol EQ-5D-3L instrument, which evaluates health status. Results are expressed as incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves.

RESULTS: The per-patient cost for ZA was £12 667, £251 higher than the equivalent cost in the no ZA group. Patients in the ZA group had on average 0.03 QALYs more than their counterparts in no ZA group. The ICER for this comparison was £8 005. Sr89 was associated with a cost of £13 230, £1365 higher than no Sr89, and a gain of 0.08 QALYs compared to no Sr89. The ICER for Sr89 was £16 884. The probabilities of ZA and Sr89 being cost-effective were 0.64 and 0.60, respectively.

CONCLUSIONS: The addition of bone-targeting treatments to standard chemotherapy led to a small improvement in QALYs for a modest increase in cost (or cost-savings). ZA and Sr89 resulted in ICERs below conventional willingness-to-pay per QALY thresholds, suggesting that their addition to chemotherapy may represent a cost-effective use of resources.