13 resultados para commercial language technology
Resumo:
We present the results of exploratory experiments using lexical valence extracted from brain using electroencephalography (EEG) for sentiment analysis. We selected 78 English words (36 for training and 42 for testing), presented as stimuli to 3 English native speakers. EEG signals were recorded from the subjects while they performed a mental imaging task for each word stimulus. Wavelet decomposition was employed to extract EEG features from the time-frequency domain. The extracted features were used as inputs to a sparse multinomial logistic regression (SMLR) classifier for valence classification, after univariate ANOVA feature selection. After mapping EEG signals to sentiment valences, we exploited the lexical polarity extracted from brain data for the prediction of the valence of 12 sentences taken from the SemEval-2007 shared task, and compared it against existing lexical resources.
Resumo:
The potential for physical removal of Mycobacterium avium ssp. paratuberculosis (M. paratuberculosis) from milk by centrifugation and microfiltration was investigated by simulating commercial processing conditions in the laboratory by means of a microcentrifuge and syringe filters, respectively. Results indicated that both centrifugation of preheated milk (60 degrees C) at 7000 x g for 10 s, and microfiltration through a filter of pore size 1.2 mu m, were capable of removing up to 95-99.9% of M. paratuberculosis cells from spiked whole milk and Middlebrook 7H9 broth suspensions, respectively. Centrifugation and microfiltration may therefore have potential application within the dairy industry as pretreatments to reduce M. paratuberculosis contamination of raw milk.
Resumo:
Purpose
– Information science has been conceptualized as a partly unreflexive response to developments in information and computer technology, and, most powerfully, as part of the gestalt of the computer. The computer was viewed as an historical accident in the original formulation of the gestalt. An alternative, and timely, approach to understanding, and then dissolving, the gestalt would be to address the motivating technology directly, fully recognizing it as a radical human construction. This paper aims to address the issues.
Design/methodology/approach
– The paper adopts a social epistemological perspective and is concerned with collective, rather than primarily individual, ways of knowing.
Findings
– Information technology tends to be received as objectively given, autonomously developing, and causing but not itself caused, by the language of discussions in information science. It has also been characterized as artificial, in the sense of unnatural, and sometimes as threatening. Attitudes to technology are implied, rather than explicit, and can appear weak when articulated, corresponding to collective repression.
Research limitations/implications
– Receiving technology as objectively given has an analogy with the Platonist view of mathematical propositions as discovered, in its exclusion of human activity, opening up the possibility of a comparable critique which insists on human agency.
Originality/value
– Apprehensions of information technology have been raised to consciousness, exposing their limitations.
Resumo:
This paper discusses a number of checks that should be carried out to ensure that the kinetic and spectroscopic measurements made using a DRIFTS cell are meaningful. The observations reported here demonstrate how an appropriately modified commercial DRIFTS cell can provide pertinent kinetic information about both gaseous products and the related surface intermediates. The oxidation of CO with 02 was used as a test to assess the catalyst bed bypass by the reaction mixture. Full CO conversion was obtained after the light-off temperature in the case of the modified cell, contrary to the case of the original cell, for which 80% of the reaction mixture bypassed the catalyst bed. The water-gas shift reaction over a Pt/CeO2 catalyst was used as a model reaction to further characterize the behavior of the cell under reaction conditions. The catalyst bed was shown not to be a dead-zone and was purged in essentially the same time as that needed to purge the cell. The reaction chamber globally operated in a quasi plug-flow mode and the gas composition in the thin catalyst bed appears to be homogeneous when operated under differential conditions. The production of the gas-phase reaction product CO2 could be simultaneously followed both by mass spectrometry and DRIFTS, both techniques leading to identical results. Various IR bands integration methods were discussed to allow a precise and accurate determination of the surface concentration of adsorbates during isotopic exchange. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
The performance of three conventional enzyme and radioimmunoassays routinely used to detect residues of anabolic steroids in cattle sera were compared with dissociation enhanced lanthanide fluorescence immunoassay (DELFIA) kits designed for the hospital market. Slight modifications to the kit reagents were required for the analysis of bovine sera. Owing to the large sample volumes used in conventional assays, detection limits were generally better than those obtained with DELFIA kits, however, assay reproducibility was enhanced using the DELFIA technology. Comparison of sera obtained from cattle implanted with anabolic steroids revealed a good correlation between alternate methods (r(2) from 0.91 to 0.97). The DELFIA kits offer a faster method for measuring estradiol, progesterone and testosterone with adequate sensitivity and in a safer environment than that encountered using radioimmunoassays.
Resumo:
Blooms of Alexandrium occur annually during the summer months in the North Channel of Cork Harbour on the south coast of Ireland. This study monitored an extensive bloom of the toxin producing Alexandrium minutum during the summer of 2011 with the use of the MIDTAL (Microarrays for the Detection of Toxic Algae) microarray and a prototype multiplex surface plasmon resonance (multi SPR) biosensor. Microarray signal intensities and toxin results from three testing platforms of the prototype multi SPR biosensor, commercial (CER) enzyme-linked immunosorbent assay (ELISA) and high performance liquid chromatography (HPLC) were compared against light microscopy counts. The main aim was to demonstrate the use of these methodologies to support national monitoring agencies by providing a faster and more accurate means of identifying and quantifying the harmful phytoplankton community and their toxins in natural water samples. Both the microarray signals and multi SPR biosensor results followed a significant trend with light microscopy results and both techniques indicated detection limits of <4000 cells of A. minutum in natural seawater samples.
Resumo:
This chapter discusses English Language Education at university and highlights a number of trends and their associated challenges in teaching and learning academic discourse. Academic discourse refers to the ways in which language is used by participants in academia. It encompasses written discourse, from article and book publishing, PhD theses to course assignments; spoken discourse, from study groups, tutorials, conference presentations to inaugural lectures; and more recently, computer-mediated discourse, from asynchronous text-based conferencing to academic blogs. The role of English language educators in preparing students and academics for successful participation in these academic events, or the academy, in English is not to be underestimated. Academic communication is not only vital to an individual’s success at university, but to the maintenance and creation of academic communities and to scientific progress itself (Hyland, 2009). This chapter presents an overview of academic discourse and discusses recent issues which have an impact on teaching and learning English at university and discusses their associated challenges: first, the increasing internationalisation of universities. Second, the emergence of a mobile academe in its broadest sense, in which students and academics move across traditional geopolitical, institutional and disciplinary boundaries, is discussed. Third, the growth of UK transnational higher education is examined as a trend which sees academics and students vicariously or otherwise involved in English language teaching and learning. Fourth, the chapter delves into the rapid and ongoing development in technology assisted and online learning. While responding to trends can be difficult, they can also inspire ingenuity. Furthermore, such trends and challenges will not emerge in the same manner in different contexts. The discussion in this chapter is illustrated with examples from a UK context but the implications of the trends and challenges are such that they reach beyond borders.
Resumo:
Transdermal drug delivery offers a number of advantages for the patient, due not only its non-invasive and convenient nature, but also factors such as avoidance of first pass metabolism and prevention of gastrointestinal degradation. It has been demonstrated that microneedle arrays can increase the number of compounds amenable to transdermal delivery by penetrating the skin's protective barrier, the stratum corneum, and creating a pathway for drug permeation to the dermal tissue below. Microneedles have been extensively investigated in recent decades for drug and vaccine delivery as well as minimally invasive patient monitoring/diagnosis. This review focuses on a range of critically important aspects of microneedle technology, namely their material composition, manufacturing techniques, methods of evaluation and commercial translation to the clinic for patient benefit and economic return. Microneedle research and development is finally now at the stage where commercialisation is a realistic possibility. However, progress is still required in the areas of scaled-up manufacture and regulatory approval.
Resumo:
As part of its single technology appraisal (STA) process, the National Institute for Health and Care Excellence (NICE) invited the company that manufactures cabazitaxel (Jevtana(®), Sanofi, UK) to submit evidence for the clinical and cost effectiveness of cabazitaxel for treatment of patients with metastatic hormone-relapsed prostate cancer (mHRPC) previously treated with a docetaxel-containing regimen. The School of Health and Related Research Technology Appraisal Group at the University of Sheffield was commissioned to act as the independent Evidence Review Group (ERG). The ERG produced a critical review of the evidence for the clinical and cost effectiveness of the technology based upon the company's submission to NICE. Clinical evidence for cabazitaxel was derived from a multinational randomised open-label phase III trial (TROPIC) of cabazitaxel plus prednisone or prednisolone compared with mitoxantrone plus prednisone or prednisolone, which was assumed to represent best supportive care. The NICE final scope identified a further three comparators: abiraterone in combination with prednisone or prednisolone; enzalutamide; and radium-223 dichloride for the subgroup of people with bone metastasis only (no visceral metastasis). The company did not consider radium-223 dichloride to be a relevant comparator. Neither abiraterone nor enzalutamide has been directly compared in a trial with cabazitaxel. Instead, clinical evidence was synthesised within a network meta-analysis (NMA). Results from TROPIC showed that cabazitaxel was associated with a statistically significant improvement in both overall survival and progression-free survival compared with mitoxantrone. Results from a random-effects NMA, as conducted by the company and updated by the ERG, indicated that there was no statistically significant difference between the three active treatments for both overall survival and progression-free survival. Utility data were not collected as part of the TROPIC trial, and were instead taken from the company's UK early access programme. Evidence on resource use came from the TROPIC trial, supplemented by both expert clinical opinion and a UK clinical audit. List prices were used for mitoxantrone, abiraterone and enzalutamide as directed by NICE, although commercial in-confidence patient-access schemes (PASs) are in place for abiraterone and enzalutamide. The confidential PAS was used for cabazitaxel. Sequential use of the advanced hormonal therapies (abiraterone and enzalutamide) does not usually occur in clinical practice in the UK. Hence, cabazitaxel could be used within two pathways of care: either when an advanced hormonal therapy was used pre-docetaxel, or when one was used post-docetaxel. The company believed that the former pathway was more likely to represent standard National Health Service (NHS) practice, and so their main comparison was between cabazitaxel and mitoxantrone, with effectiveness data from the TROPIC trial. Results of the company's updated cost-effectiveness analysis estimated a probabilistic incremental cost-effectiveness ratio (ICER) of £45,982 per quality-adjusted life-year (QALY) gained, which the committee considered to be the most plausible value for this comparison. Cabazitaxel was estimated to be both cheaper and more effective than abiraterone. Cabazitaxel was estimated to be cheaper but less effective than enzalutamide, resulting in an ICER of £212,038 per QALY gained for enzalutamide compared with cabazitaxel. The ERG noted that radium-223 is a valid comparator (for the indicated sub-group), and that it may be used in either of the two care pathways. Hence, its exclusion leads to uncertainty in the cost-effectiveness results. In addition, the company assumed that there would be no drug wastage when cabazitaxel was used, with cost-effectiveness results being sensitive to this assumption: modelling drug wastage increased the ICER comparing cabazitaxel with mitoxantrone to over £55,000 per QALY gained. The ERG updated the company's NMA and used a random effects model to perform a fully incremental analysis between cabazitaxel, abiraterone, enzalutamide and best supportive care using PASs for abiraterone and enzalutamide. Results showed that both cabazitaxel and abiraterone were extendedly dominated by the combination of best supportive care and enzalutamide. Preliminary guidance from the committee, which included wastage of cabazitaxel, did not recommend its use. In response, the company provided both a further discount to the confidential PAS for cabazitaxel and confirmation from NHS England that it is appropriate to supply and purchase cabazitaxel in pre-prepared intravenous-infusion bags, which would remove the cost of drug wastage. As a result, the committee recommended use of cabazitaxel as a treatment option in people with an Eastern Cooperative Oncology Group performance status of 0 or 1 whose disease had progressed during or after treatment with at least 225 mg/m(2) of docetaxel, as long as it was provided at the discount agreed in the PAS and purchased in either pre-prepared intravenous-infusion bags or in vials at a reduced price to reflect the average per-patient drug wastage.