43 resultados para Wavelength pumping


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Multipulse irradiation with 100 ps pulses of stripe Germanium targets is shown to enhance by up to several orders-of-magnitude the output of Ne-like Ge lasing on the J = 0-1 line at 196 Angstrom compared to single pulse pumping. Various pre-pulse and multipulse configurations have been experimentally investigated for irradiances of approximate to 4 x 10(13) W/cm(2) with a 1.06 mu m wavelength pumping laser. The ionisation balance measured by a KeV crystal spectrometer (KAP crystal) has been found to not affect the X-ray laser output. Good agreement between the experimental results and a fluid code incorporating atomic physics, gain and X-ray beam ray tracing is obtained. The code results show that the enhanced X-ray laser output is produced by multipulse irradiation reducing the electron density gradients in the gain region and simultaneously increasing the gain region spatial size. These changes reduce the effect of refraction on the X-ray laser beam propagation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a systematic study of double pulse pumping of the Ni-like Sm x-ray laser at 73 Angstrom, currently the shortest wavelength saturated x-ray laser. It is found that the Sm x-ray laser output can change by orders of magnitude when the intensity ratio of the pumping pulses and their relative delay are varied. Optimum pumping conditions are found and interpreted in terms of a simple model. (C) 1999 American Institute of Physics. [S0021-8979(99)07102-9].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raman microscopy, based upon the inelastic scattering (Raman) of light by molecular species, has been applied as a specific structural probe in a wide range of biomedical samples. The purpose of the present investigation was to assess the potential of the technique for spectral characterization of the porcine outer retina derived from the area centralis, which contains the highest proportion of cone:rod cell ratio in the pig retina. METHODS: Retinal cross-sections, immersion-fixed in 4% (w/v) PFA and cryoprotected, were placed on salinized slides and air-dried prior to direct Raman microscopic analysis at three excitation wavelengths, 785 nm, 633 nm, and 514 nm. RESULTS: Raman spectra of each of the photoreceptor inner and outer segments (PIS, POS) and of the outer nuclear layer (ONL) of the retina acquired at 785 nm were dominated by vibrational features characteristic of proteins and lipids. There was a clear difference between the inner and outer domains in the spectroscopic regions, amide I and III, known to be sensitive to protein conformation. The spectra recorded with 633 nm excitation mirrored those observed at 785 nm excitation for the amide I region, but with an additional pattern of bands in the spectra of the PIS region, attributed to cytochrome c. The same features were even more enhanced in spectra recorded with 514 nm excitation. A significant nucleotide contribution was observed in the spectra recorded for the ONL at all three excitation wavelengths. A Raman map was constructed of the major spectral components found in the retinal outer segments, as predicted by principal component analysis of the data acquired using 633 nm excitation. Comparison of the Raman map with its histological counterpart revealed a strong correlation between the two images. CONCLUSIONS: It has been demonstrated that Raman spectroscopy offers a unique insight into the biochemical composition of the light-sensing cells of the retina following the application of standard histological protocols. The present study points to the considerable promise of Raman microscopy as a component-specific probe of retinal tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we have conclusively proven that the "enhanced" optical transmission through a periodic array of sub-wavelength holes in metal films (Ebbessen's experiment) is the result of the array periodicity. This work has overturned the commonly accepted theory that the surface plasmons were responsible for the transmission enhancement. It was demonstrated that the reflectance, transmittance and frequency selectivity of the multilayered arrays can be efficiently modified by the aperture shapes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since 1995, when pumps were withdrawn from deep mines in East Fife (Scotland), mine waters have been rebounding throughout the coalfield. Recently, it has become necessary to pump and treat these waters to prevent their uncontrolled emergence at the surface. However, even relatively shallow pumping to surface treatment lagoons of the initially chemically-stratified mine water from a shaft in the coastal Frances Colliery during two dynamic step-drawdown tests to establish the hydraulic characteristics of the system resulted in rapid breakdown of the stratification within 24 h and a poor pumped water quality with high dissolved Fe loading. Further, data are presented here of hydrochemical and isotopic sampling of the extended pump testing lasting up to several weeks. The use in particular of the environmental isotopes d18O, d2H, d34S, 3H, 13C and 14C alongside hydrochemical and hydraulic pump test data allowed characterisation of the Frances system dynamics, mixing patterns and water quality sources feeding into this mineshaft under continuously pumped conditions. The pumped water quality reflects three significant components of mixing: shallow freshwater, seawater, and leakage from the surface treatment lagoons. In spite of the early impact of recirculating lagoon waters on the hydrochemistries, the highest Fe loadings in the longer-term pumped waters are identified with a mixed freshwater–seawater component affected by pyrite oxidation/melanterite dissolution in the subsurface system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impedance and radiation pattern parameters of a lambda/2 quadrifilar helix antenna (QHA) with turn angles in the range 0 degrees to 235 degrees are analyzed. It is shown that by selecting the helix turn angle to satisfy the minimum bandwidth and beamwidth requirements, an improved electrical performance and a reduction in the physical size of the antenna is obtained. This is demonstrated by comparing the performance of a conventional half turn QHA with structures having a smaller pitch length. The computed results are validated by experimental data at L-band.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent experiments undertaken at the Rutherford Appleton Laboratory to produce X-ray lasing over the 5-30 nm wavelength range are reviewed. The efficiency of lasing is optimized when the main pumping pulse interacts with a preformed plasma. Experiments using double 75-ps pulses and picosecond pulses superimposed on 300-ps background pulses are described. The use of travelling wave pumping with the approximately picosecond pulse experiments is necessary as the gain duration becomes comparable to the time for the X-ray laser pulse to propagate along the target length. Results from a model taking account of laser saturation and deviations from the speed of light c of the travelling wave and X-ray laser group velocity are presented. We show that X-ray laser pulses as short as 2-3 ps can be produced with optical pumping pulses of approximate to1-ps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a time-resolved study of a Ni-like transient collisionnal X-ray laser with a resolution as high as 1.9 ps The FWHM duration of the Ni-like x-ray laser pulse at 13.99 nin Ag J = 0 -->1 4d-4p line is measured to be as short as similar to2 ps at optimum conditions of pump laser irradiation. This is about four times shorter than was estimated in previous experiments. The x-ray laser signal appears in the rising edge of the continuum emission. The x-ray laser duration rises significantly when the short (heating) pulse duration is increased and when doubling the peak-to-peak delay of the two irradiation pulses, It does not change when the short pulse energy is increased. The results presented are the first direct measurements of the temporal profile of the x-ray laser output at a high resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saturated output has been observed for both Ne and Ni-like X-ray lasers when Pumped in the transient mode. As these 'normal' transitions display very high gain, attempts have been made to observe a 2p --> 2s inner shell transition in Ne-like ions, which scale well towards the water window. Modelling of the pump conditions for Ge lasing at 6.2 run is presented. As the predicted gain is low the experiment was set up for 18 mm targets. Shots were taken on Ti, Fe, Ni and Ge. A similar to1.5 ps travelling wave pulse is applied at various times after the peak of a long, preforming Pulse. Various pump conditions were attempted but no inner shell X-ray laser was detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NADH:ubiquinone oxidoreductase (complex I) is the largest and most complicated enzyme of aerobic electron transfer. The mechanism how it uses redox energy to pump protons across the bioenergetic membrane is still not understood. Here we determined the pumping stoichiometry of mitochondrial complex I from the strictly aerobic yeast Yarrowia lipolytica. With intact mitochondria, the measured value of 3.8H(->+)/2e(-) indicated that four protons are pumped per NADH oxidized. For purified complex I reconstituted into proteoliposomes we measured a very similar pumping stoichiometry of 3.6H(->+)/2e(-). This is the first demonstration that the proton pump of complex I stayed fully functional after purification of the enzyme. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanism of energy converting NADH:ubiquinone oxidoreductase (complex 1) is Still unknown. A current controversy centers around the question whether electron transport of complex I is always linked to vectorial proton translocation or whether in some organisms the enzyme pumps sodium ions instead. To develop better experimental tools to elucidate its mechanism, we have reconstituted the affinity purified enzyme into proteoliposomes and monitored the generation of Delta pH and Delta psi. We tested several detergents to solubilize the asolectin used for liposome formation. Tightly coupled proteoliposomes containing highly active complex I were obtained by detergent removal with BioBeads after total solubilization or the phospholipids with n-octyl-beta-D-glucopyranoside. We have used dyes to monitor the formation of the two components of the proton motive force, Delta pH and Delta psi, across the liposomal membrane, and analyzed the effects of inhibitors, uncouplers and ionophores on this process. We show that electron transfer of complex I of the lower eukaryote Y. lipolytica is clearly linked to proton translocation. While this study was not specifically designed to demonstrate possible additional sodium translocating properties of complex 1, we did not find indications for primary or secondary Na+ translocation by Y lipolytica complex I. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental results are presented for the focusing capability of an active phase conjugating lens for a single and a dipole source pair and these are compared with predictions. In addition for a single source we illustrate the ability of the lens to project a null at the lens focus instead of a peak. A scheme is also presented such that when a source or pair of sources is imaged through an identical pair of passive scatterers located symmetrically about the lens that imaging with sub-wavelength resolution is possible. The rationale for the operation of the lens and aberrations observed due to its finite array size is discussed and is supported throughout by means of numerical simulation.