7 resultados para Timber structures
Resumo:
The research and development of connecting and strengthening timber structural elements with glued-inrods (GiR) has been ongoing since the 1980s. Despite many successful applications in practice, agreement regarding design criteria has not been reached. This state-of-the-art review summarises results from both research and practical applications regarding connections and reinforcement with GiR. The review considers manufacturing methods, mechanisms and parameters governing the performance and strength of GiR, theoretical approaches to estimate their load-bearing capacity and existing design recommendations.
Resumo:
Timber engineering has advanced over recent decades to offer an alternative to traditional materials and methods. The bonding of fibre reinforced plastics (FRP) with adhesives to timber structures for repair and strengthening has many advantages. However, the lack of established design rules has strongly restrained the use of FRP strengthening in many situations, where these could be a preferable option to most traditional techniques. A significant body of research has been carried out in recent years on the performance of FRP reinforced timber and engineered wood products. This paper gives a State of the Art summary of material formulations, application areas, design approaches and quality control issues for practical engineers to introduce on-site bonding of FRP to timber as a new way in design for structural repair and rehabilitation.
Resumo:
Many timber structures may require strengthening due to either decay and aging or an increase of load. This paper presents an experimental study in which eleven timber beams were tested, including three unstrengthened reference beams and eight beams strengthened with NSM CFRP bars. The test parameters include the position of NSM (tensile face or the bottom of the sides), the number of CFRP bars (1 or 2), and additional anchorage of NSM CFRP bars (steel wire U anchors or CFRP U strips). The test results show that the ultimate flexural strength of the timber beams were increased by 14%∼85% with an average of 47% due to NSM CFRP bar strengthening. Their deflection corresponding to the peak load was increased by 33% in average.
Resumo:
Synopsis: Bonded-in rod timber joints off er several advantages over conventional types of joint, including high local force transfer, very stiff connections, and improved ?re and aesthetic properties since the connection is completely hidden in the insulating timber members. More recently, the use of ?bre reinforced polymer (FRP) as a connecting rod, alternative to steel rods, in bonded-in rod connections for timber structures has been investigated. However, the investigation into the behaviour of such joints is limited, in particular, connections involving basalt ?bre reinforced polymers (BFRP) bars - which is the primary focus of this research. This paper presents an experimental programme conducted to investigate the behaviour of bonded-in BFRP bars loaded parallel to the grain of glulam members. Tensile pull-out tests were conducted to examine the effect of bonded length and bond stress-slip on the structural capacity of the connection. An analytical design expression for predicting pull-out capacity is proposed and the results have been compared with some established design equations. It was found that pull-out load increased approximately linearly with the bonded length, up to maximum which occurred at a bonded length of 15 times the hole diameter, and did not increase beyond this bonded length. The most signi?cant failure modes were failure at the timber/adhesive interface followed by pullout of the BFRP rod. Increased bonded lengths resulted in higher bond slip values compared to lower equivalent bonded lengths. The proposed design model gave the best predictions of pull-out capacity compared with other existing models.
Resumo:
Glued-in rods (GiR) have been successfully used for both constructing new and strengthening existing timber structures. The research and development of connecting and strengthening timber structural elements with GiR has been going on since the 1980s. However, agreement regarding design criteria for these applications has not been reached. Today, some few technical approvals for specific adhesives suitable to GiR exist, but an approach for the design of connections or reinforcement with GiR has not been included in the European design code EN 1995 so far. Therefore, it is desired to gather the current state of knowledge to enable application in practice of the existing and documented knowledge and experience. This state-of-the-art review (STAR) summarises results from research done regarding connections and reinforcement with GiR. The review considers manufacturing methods, mechanisms and parameters governing the performance and strength of GiR, theoretical approaches and existing design recommendations. For GiR applied as reinforcement similar rules and requirements apply as for GiR being used as connectors.
Resumo:
In the early 19th century the requirement for clear span industrial buildings brought about the development of a variety of timber truss types. The Belfast truss was introduced circa 1860 to meet the demand for efficient wide span industrial buildings. It has essentially a bow-string configuration with a curved top chord, straight horizontal bottom chord and close-spaced lattice web. Several thousand still exist in Ireland, many in buildings of historic significance. This paper sets out to demonstrate the efficiency of the Belfast truss and to show that, by modern structural design criteria, the concept, member sizes and joint details were well chosen. Trusses in historic buildings can be replicated almost exactly as originally fabricated. Results of a theoretical study are compared with the experimental behaviour of two full-scale trusses: one a replacement truss, tested in the laboratory; the other an 80-year-old truss tested on site. In addition, experimental results from a manufacturers archive material of full-scale truss tests carried out about 100 years ago are compared with theoretical models. As well as considering their significance in building conservation the paper proposes that Belfast trusses are an attractive sustainable alternative to other roof structures. The analysis, design, fabrication and testing of trusses have resulted in a better understanding of their behaviour which is not only of historic interest and fundamental to the repair/restoration of existing trusses, but also relevant to the design of modern timber trusses and the promotion of a sustainable form of roof construction.