86 resultados para Shortening of duration of studies


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Systematic reviews and meta-analyses are essential to summarize evidence relating to efficacy and safety of health care interventions accurately and reliably. The clarity and transparency of these reports, however, is not optimal. Poor reporting of systematic reviews diminishes their value to clinicians, policy makers, and other users. Since the development of the QUOROM (QUality Of Reporting Of Meta-analysis) Statement-a reporting guideline published in 1999-there have been several conceptual, methodological, and practical advances regarding the conduct and reporting of systematic reviews and meta-analyses. Also, reviews of published systematic reviews have found that key information about these studies is often poorly reported. Realizing these issues, an international group that included experienced authors and methodologists developed PRISMA ( Preferred Reporting Items for Systematic reviews and Meta-Analyses) as an evolution of the original QUOROM guideline for systematic reviews and meta-analyses of evaluations of health care interventions. The PRISMA Statement consists of a 27-item checklist and a four-phase flow diagram. The checklist includes items deemed essential for transparent reporting of a systematic review. In this Explanation and Elaboration document, we explain the meaning and rationale for each checklist item. For each item, we include an example of good reporting and, where possible, references to relevant empirical studies and methodological literature. The PRISMA Statement, this document, and the associated Web site (http://www.prisma-statement.org/) should be helpful resources to improve reporting of systematic reviews and metaanalyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Underpinning current models of the mechanisms of the action of radiation is a central role for DNA damage and in particular double-strand breaks (DSBs). For radiations of different LET, there is a need to know the exact yields and distributions of DSBs in human cells. Most measurements of DSB yields within cells now rely on pulsed-field gel electrophoresis as the technique of choice. Previous measurements of DSB yields have suggested that the yields are remarkably similar for different types of radiation with RBE values less than or equal to1.0. More recent studies in mammalian cells, however, have suggested that both the yield and the spatial distribution of DSBs are influenced by radiation quality. RBE values for DSBs induced by high-LET radiations are greater than 1.0, and the distributions are nonrandom. Underlying this is the interaction of particle tracks with the higher-order chromosomal structures within cell nuclei. Further studies are needed to relate nonrandom distributions of DSBs to their rejoining kinetics. At the molecular level, we need to determine the involvement of clustering of damaged bases with strand breakage, and the relationship between higher-order clustering over sizes of kilobase pairs and above to localized clustering at the DNA level. Overall, these studies will allow us to elucidate whether the nonrandom distributions of breaks produced by high-LET particle tracks have any consequences for their repair and biological effectiveness. (C) 2001 by Radiation Research Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background
Mechanical ventilation is a life-saving intervention for critically ill newborn infants with respiratory failure admitted to a neonatal intensive care unit (NICU). Ventilating newborn infants can be challenging due to small tidal volumes, high breathing frequencies, and the use of uncuffed endotracheal tubes. Mechanical ventilation has several short-term, as well as long-term complications. To prevent complications, weaning from the ventilator is started as soon as possible. Weaning aims to support the transfer from full mechanical ventilation support to spontaneous breathing activity.

Objectives
To assess the efficacy of protocolized versus non-protocolized ventilator weaning for newborn infants in reducing the duration of invasive mechanical ventilation, the duration of weaning, and shortening the NICU and hospital length of stay. To determine efficacy in predefined subgroups including: gestational age and birth weight; type of protocol; and type of protocol delivery. To establish whether protocolized weaning is safe and clinically effective in reducing the duration of mechanical ventilation without increasing the risk of adverse events.

Search methods
We searched the Cochrane Central Register of Controlled trials (CENTRAL; the Cochrane Library; 2015, Issue 7); MEDLINE In-Process and other Non-Indexed Citations and OVID MEDLINE (1950 to 31 July 2015); CINAHL (1982 to 31 July 2015); EMBASE (1988 to 31 July 2015); and Web of Science (1990 to 15 July 2015). We did not restrict language of publication. We contacted authors of studies with a subgroup of newborn infants in their study, and experts in the field regarding this subject. In addition, we searched abstracts from conference proceedings, theses, dissertations, and reference lists of all identified studies for further relevant studies.

Selection criteria
Randomized, quasi-randomized or cluster-randomized controlled trials that compared protocolized with non-protocolized ventilator weaning practices in newborn infants with a gestational age of 24 weeks or more, who were enrolled in the study before the postnatal age of 28 completed days after the expected date of birth.

Data collection and analysis
Four authors, in pairs, independently reviewed titles and abstracts identified by electronic searches. We retrieved full-text versions of potentially relevant studies.

Main results
Our search yielded 1752 records. We removed duplicates (1062) and irrelevant studies (843). We did not find any randomized, quasi-randomized or cluster-randomized controlled trials conducted on weaning from mechanical ventilation in newborn infants. Two randomized controlled trials met the inclusion criteria on type of study and type of intervention, but only included a proportion of newborns. The study authors could not provide data needed for subgroup analysis; we excluded both studies.

Authors' conclusions
Based on the results of this review, there is no evidence to support or refute the superiority or inferiority of weaning by protocol over non-protocol weaning on duration of invasive mechanical ventilation in newborn infants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To investigate the effects of weaning protocols on the total duration of mechanical ventilation, mortality, adverse events, quality of life, weaning duration, and length of stay in the intensive care unit and hospital.

Design Systematic review.

Data sources Cochrane Central Register of Controlled Trials, Medline, Embase, CINAHL, LILACS, ISI Web of Science, ISI Conference Proceedings, Cambridge Scientific Abstracts, and reference lists of articles. We did not apply language restrictions.

Review methods We included randomised and quasi-randomised controlled trials of weaning from mechanical ventilation with and without protocols in critically ill adults.

Data selection Three authors independently assessed trial quality and extracted data. A priori subgroup and sensitivity analyses were performed. We contacted study authors for additional information.

Results Eleven trials that included 1971 patients met the inclusion criteria. Compared with usual care, the geometric mean duration of mechanical ventilation in the weaning protocol group was reduced by 25% (95% confidence interval 9% to 39%, P=0.006; 10 trials); the duration of weaning was reduced by 78% (31% to 93%, P=0.009; six trials); and stay in the intensive care unit length by 10% (2% to 19%, P=0.02; eight trials). There was significant heterogeneity among studies for total duration of mechanical ventilation (I(2)=76%, P

Conclusion There is evidence of a reduction in the duration of mechanical ventilation, weaning, and stay in the intensive care unit when standardised weaning protocols are used, but there is significant heterogeneity among studies and an insufficient number of studies to investigate the source of this heterogeneity. Some studies suggest that organisational context could influence outcomes, but this could not be evaluated as it was outside the scope of this review.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent.

OBJECTIVES: To assess the effects of protocolized weaning from mechanical ventilation on the total duration of mechanical ventilation for critically ill adults; ascertain differences between protocolized and non-protocolized weaning in terms of mortality, adverse events, quality of life, weaning duration, intensive care unit (ICU) and hospital length of stay (LOS); and explore variation in outcomes by type of ICU, type of protocol and approach to delivering the protocol.

SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2010), MEDLINE (1950 to 2010), EMBASE (1988 to 2010), CINAHL (1937 to 2010), LILACS (1982 to 2010), ISI Web of Science and ISI Conference Proceedings (1970 to 2010), Cambridge Scientific Abstracts (inception to 2010) and reference lists of articles. We did not apply language restrictions.

SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults.

DATA COLLECTION AND ANALYSIS: Three authors independently assessed trial quality and extracted data. A priori subgroup and sensitivity analyses were performed. We contacted study authors for additional information.

MAIN RESULTS: Eleven trials that included 1971 patients met the inclusion criteria. The total duration of mechanical ventilation geometric mean in the protocolized weaning group was on average reduced by 25% compared with the usual care group (N = 10 trials, 95% CI 9% to 39%, P = 0.006); weaning duration was reduced by 78% (N = 6 trials, 95% CI 31% to 93%, P = 0.009); and ICU LOS by 10% (N = 8 trials, 95% CI 2% to 19%, P = 0.02). There was significant heterogeneity among studies for total duration of mechanical ventilation (I(2) = 76%, P <0.01) and weaning duration (I(2) = 97%, P <0.01), which could not be explained by subgroup analyses based on type of unit or type of approach.

AUTHORS' CONCLUSIONS: There is some evidence of a reduction in the duration of mechanical ventilation, weaning duration and ICU LOS with use of standardized protocols, but there is significant heterogeneity among studies and an insufficient number of studies to investigate the source of this heterogeneity. Although some study authors suggest that organizational context may influence outcomes, these factors were not considered in all included studies and therefore could not be evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:Mechanical ventilation is a critical component of paediatric intensive care therapy. It is indicated when the patient’s spontaneous ventilation is inadequate to sustain life. Weaning is the gradual reduction of ventilatory support and the transfer of respiratory control back to the patient. Weaning may represent a large proportion of the ventilatory period. Prolonged ventilation is associated with significant morbidity, hospital cost, psychosocial and physical risks to the child and even death. Timely and effective weaning may reduce the duration of mechanical ventilation and may reduce the morbidity and mortality associated with prolonged ventilation. However, no consensus has been reached on criteria that can be used to identify when patients are ready to wean or the best way to achieve it.Objectives:To assess the effects of weaning by protocol on invasively ventilated critically ill children. To compare the total duration of invasive mechanical ventilation of critically ill children who are weaned using protocols versus those weaned through usual (non-protocolized) practice. To ascertain any differences between protocolized weaning and usual care in terms of mortality, adverse events, intensive care unit length of stay and quality of life.Search methods:We searched the Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library, Issue 10, 2012), MEDLINE (1966 to October 2012), EMBASE (1988 to October 2012), CINAHL (1982 to October 2012), ISI Web of Science and LILACS. We identified unpublished data in the Web of Science (1990 to October 2012), ISI Conference Proceedings (1990 to October 2012) and Cambridge Scientific Abstracts (earliest to October 2012). We contacted first authors of studies included in the review to obtain further information on unpublished studies or work in progress. We searched reference lists of all identified studies and review papers for further relevant studies. We applied no language or publication restrictions.Selection criteriaWe included randomized controlled trials comparing protocolized weaning (professional-led or computer-driven) versus non-protocolized weaning practice conducted in children older than 28 days and younger than 18 years.Data collection and analysis:Two review authors independently scanned titles and abstracts identified by electronic searching. Three review authors retrieved and evaluated full-text versions of potentially relevant studies, independently extracted data and assessed risk of bias.Main results:We included three trials at low risk of bias with 321 children in the analysis. Protocolized weaning significantly reduced total ventilation time in the largest trial (260 children) by a mean of 32 hours (95% confidence interval (CI) 8 to 56; P = 0.01). Two other trials (30 and 31 children, respectively) reported non-significant reductions with a mean difference of -88 hours (95% CI -228 to 52; P = 0.2) and -24 hours (95% CI -10 to 58; P = 0.06). Protocolized weaning significantly reduced weaning time in these two smaller trials for a mean reduction of 106 hours (95% CI 28 to 184; P = 0.007) and 21 hours (95% CI 9 to 32; P < 0.001). These studies reported no significant effects for duration of mechanical ventilation before weaning, paediatric intensive care unit (PICU) and hospital length of stay, PICU mortality or adverse events.Authors' conclusions:Limited evidence suggests that weaning protocols reduce the duration of mechanical ventilation, but evidence is inadequate to show whether the achievement of shorter ventilation by protocolized weaning causes children benefit or harm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE - The aim if the study was to investigate whether children born to older mothers have an increased risk of type 1 diabetes by performing a pooled analysis of previous studies using individual patient data to adjust for recognized confounders.
RESEARCH DESIGN AND METHODS - Relevant studies published before June 2009 were identified from MEDLINE, Web of Science, and EMBASE. Authors of studies were contacted and asked to provide individual patient data or conduct prespecified analyses. Risk estimates of type 1 diabetes by maternal age were calculated for each study, before and after adjustment for potential confounders. Meta-analysis techniques were used to derive combined odds ratios and to investigate heterogeneity among studies.
RESULTS - Data were available for 5 cohort and 25 case-control studies, including 14,724 cases of type 1 diabetes. Overall, there was, on average, a 5% (95% CI 2-9) increase in childhood type 1 diabetes odds per 5-year increase in maternal age (P = 0.006), but there was heterogeneity among studies (heterogeneity I 2 = 70%). In studies with a low risk of bias, there was a more marked increase in diabetes odds of 10% per 5-year increase in maternal age. Adjustments for potential confounders little altered these estimates. CONCLUSIONS - There was evidence of a weak but significant linear increase in the risk of childhood type 1 diabetes across the range of maternal ages, but the magnitude of association varied between studies. A very small percentage of the increase in the incidence of childhood type 1 diabetes in recent years could be explained by increases in maternal age.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The incidence rates of childhood onset type 1 diabetes are almost universally increasing across the globe but the aetiology of the disease remains largely unknown. We investigated whether birth order is associated with the risk of childhood diabetes by performing a pooled analysis of previous studies. Methods: Relevant studies published before January 2010 were identified from MEDLINE, Web of Science and EMBASE. Authors of studies provided individual patient data or conducted pre-specified analyses. Meta-analysis techniques were used to derive combined odds ratios (ORs), before and after adjustment for confounders, and investigate heterogeneity. Results: Data were available for 6 cohort and 25 case-control studies, including 11 955 cases of type 1 diabetes. Overall, there was no evidence of an association prior to adjustment for confounders. After adjustment for maternal age at birth and other confounders, a reduction in the risk of diabetes in second-or later born children became apparent [fully adjusted OR=0.90 95% confidence interval (CI) 0.83-0.98; P=0.02] but this association varied markedly between studies (I 2=67%). An a priori subgroup analysis showed that the association was stronger and more consistent in children <5years of age (n=25 studies, maternal age adjusted OR=0.84 95% CI 0.75, 0.93; I 2=23%). Conclusion: Although the association varied between studies, there was some evidence of a lower risk of childhood onset type 1 diabetes with increasing birth order, particularly in children aged <5 years. This finding could reflect increased exposure to infections in early life in later born children. Published by Oxford University Press on behalf of the International Epidemiological Association © The Author 2010; all rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although there have been a number of studies in adults, to date there has been little research into sequential antimicrobial therapy (SAT) in paediatric populations. The present study evaluates the impact of a SAT protocol for the treatment of severe lower respiratory tract infection in paediatric patients. The study involved 89 paediatric patients (44 control and 45 SAT). The SAT patients had a shorter length of hospital stay (4.0 versus 8.3 days), shorter duration of inpatient antimicrobial therapy (4.0 versus 7.9 days) with the period of iv therapy being reduced from a mean of 5.6 to 1.7 days. The total healthcare costs were reduced by 52%. The resolution of severe lower respiratory tract infection with a short course of iv antimicrobials, followed by conversion to oral therapy yielded clinical outcomes comparable to those achieved using longer term iv therapy. SAT proved to be an important cost-minimizing tool for realizing substantial healthcare costs savings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Scanning laser polarimetry (SLP) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the SLP for diagnosing glaucoma. METHODS: A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the SLP for glaucoma was performed. Two reviewers independently selected and appraised the manuscripts. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS: A total of 47 papers were identified of which the first 10 (from 1997 to 2000) and the last 10 articles (from 2004 to 2005) were appraised. Interobserver rating agreement of STARD items was high (85.5% agreement, ?=0.796). The number of STARD items properly reported ranged from 3/25 to 19/25. Only a quarter of studies (5/20) explicitly reported more than half of the STARD items. Important aspects of the methodology were often missing such as participant sampling (reported in 40% of manuscripts), masking of the readers of the index test and reference standard (reported in 20% of manuscripts), and estimation of uncertainty (eg, 95% confidence intervals, reported in 25% of manuscripts). There was a slight increase in the number of STARD items reported with time. CONCLUSIONS: The quality of reporting of diagnostic accuracy tests for glaucoma with SLP is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. © 2007 Lippincott Williams & Wilkins, Inc.