13 resultados para Reproducible method


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The comet assay is a technique used to quantify DNA damage and repair at a cellular level. In the assay, cells are embedded in agarose and the cellular content is stripped away leaving only the DNA trapped in an agarose cavity which can then be electrophoresed. The damaged DNA can enter the agarose and migrate while the undamaged DNA cannot and is retained. DNA damage is measured as the proportion of the migratory ‘tail’ DNA compared to the total DNA in the cell. The fundamental basis of these arbitrary values is obtained in the comet acquisition phase using fluorescence microscopy with a stoichiometric stain in tandem with image analysis software. Current methods deployed in such an acquisition are expected to be both objectively and randomly obtained. In this paper we examine the ‘randomness’ of the acquisition phase and suggest an alternative method that offers both objective and unbiased comet selection. In order to achieve this, we have adopted a survey sampling approach widely used in stereology, which offers a method of systematic random sampling (SRS). This is desirable as it offers an impartial and reproducible method of comet analysis that can be used both manually or automated. By making use of an unbiased sampling frame and using microscope verniers, we are able to increase the precision of estimates of DNA damage. Results obtained from a multiple-user pooled variation experiment showed that the SRS technique attained a lower variability than that of the traditional approach. The analysis of a single user with repetition experiment showed greater individual variances while not being detrimental to overall averages. This would suggest that the SRS method offers a better reflection of DNA damage for a given slide and also offers better user reproducibility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Elucidation of the transcriptome and proteome of the normal retina will be difficult since it is comprised of at least 55 different cell types. However the characteristic layered cellular anatomy of the retina makes it amenable to planar sectioning, enabling the generation of enriched retinal cell populations. The aim of this study was to validate a reproducible method for preparing enriched retinal layers from porcine retina.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Monitoring multiple myeloma patients for relapse requires sensitive methods to measure minimal residual disease and to establish a more precise prognosis. The present study aimed to standardize a real-time quantitative polymerase chain reaction (PCR) test for the IgH gene with a JH consensus self-quenched fluorescence reverse primer and a VDJH or DJH allele-specific sense primer (self-quenched PCR). This method was compared with allele-specific real-time quantitative PCR test for the IgH gene using a TaqMan probe and a JH consensus primer (TaqMan PCR). We studied nine multiple myeloma patients from the Spanish group treated with the MM2000 therapeutic protocol. Self-quenched PCR demonstrated sensitivity of >or=10(-4) or 16 genomes in most cases, efficiency was 1.71 to 2.14, and intra-assay and interassay reproducibilities were 1.18 and 0.75%, respectively. Sensitivity, efficiency, and residual disease detection were similar with both PCR methods. TaqMan PCR failed in one case because of a mutation in the JH primer binding site, and self-quenched PCR worked well in this case. In conclusion, self-quenched PCR is a sensitive and reproducible method for quantifying residual disease in multiple myeloma patients; it yields similar results to TaqMan PCR and may be more effective than the latter when somatic mutations are present in the JH intronic primer binding site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In agroecosystems, most isotopic investigations of NO3- involve the use of tracers that are artificially enriched in 15N. Although the dual isotope composition of NO3-— d15N and d18O is especially beneficial for understanding the origin and fate of NO3-, its use for KCl-extractable soil NO3- has been hampered by the lack of a suitable analytical technique. Our objective was to test whether the denitrifier method, whereby NO3- is reduced to N2O before mass spectrometric analysis, can be used to determine the N and O isotopic composition of NO3- from 2 M KCl soil extracts. Several internationally accepted NO3- standards were dissolved in 2 M KCl, the conventional extractant for soil inorganic N, and inoculated with the bacterial strain Pseudomonas aureofaciens (ATCC no. 13985). The standard deviation of the NO3- standards analyzed did not exceed 0.2‰ for d15N and 0.3‰ for d18O values. After appropriate corrections, differences between our measured and consensus d15N and d18O values of standard NO3- generally were within the standard deviations given for the consensus values. Both d15N and d18O values were reproducible among separate analytical runs. The method was also tested on genuine 2 M KCl extracts from unfertilized and fertilized soils. Depending on N fertilization, the soils had distinct d15N and d18O values, which were attributed to amendment with NH4NO3 fertilizer. Hence, our data indicate that the denitrifier method provides a fast, reliable, precise, and accurate way of simultaneously analyzing the natural abundances of 15N and 18O in KCl-extractable soil NO3-.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large numbers of identical and stable SE(R)RS [surface-enhanced (resonance) Raman]-active media, which are convenient to handle and manipulate but sufficiently inexpensive that they can be used once and then discarded, have been prepared by isolating nanoparticles from Ag and Au sols in hydrophilic polymer gels. The preparation simply involves mixing a suitable polymer with the sol to give a viscous suspension that can be coated onto a substrate and dried to form a hard translucent film. The films remain inactive until they are treated with aqueous analyte solution, which causes the film to swell and brings the analyte into contact with the active metal particles. The swollen films give strong SERS spectra which are effectively identical to those obtained from simple sols. The advantage of this method is that the dried polymers can be stored indefinitely before use and that they give a high degree of spectral reproducibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Index properties such as the liquid limit and plastic limit are widely used to evaluate certain geotechnical parameters of fine-grained soils. Measurement of the liquid limit is a mechanical process, and the possibility of errors occurring during measurement is not significant. However, this is not the case for plastic limit testing, despite the fact that the current method of measurement is embraced by many standards around the world. The method in question relies on a fairly crude procedure known widely as the ‘thread rolling' test, though it has been the subject of much criticism in recent years. It is essential that a new, more reliable method of measuring the plastic limit is developed using a mechanical process that is both consistent and easily reproducible. The work reported in this paper concerns the development of a new device to measure the plastic limit, based on the existing falling cone apparatus. The force required for the test is equivalent to the application of a 54 N fast-static load acting on the existing cone used in liquid limit measurements. The test is complete when the relevant water content of the soil specimen allows the cone to achieve a penetration of 20 mm. The new technique was used to measure the plastic limit of 16 different clays from around the world. The plastic limit measured using the new method identified reasonably well the water content at which the soil phase changes from the plastic to the semi-solid state. Further evaluation was undertaken by conducting plastic limit tests using the new method on selected samples and comparing the results with values reported by local site investigation laboratories. Again, reasonable agreement was found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The laboratory mouse is a powerful tool in cardiovascular research. In this report, we describe a method for a reproducible mouse myocardial infarction model that would allow subsequent comparative and quantitative studies on molecular and pathophysiological variables. Methods: (A) The distribution of the major coronary arteries including the septal artery in the left ventricle of the C57BL/6J mice (n=20) was mapped by perfusion of latex dye or fluorescent beads through the aorta. (B) The territory of myocardial infarction after the ligation of the most proximal aspect of the left anterior descending (LAD) coronary artery was quantified. (C) The consistency in the histological changes parallel to the infarction at different time points was analyzed. Results: (A) The coronary artery tree of the mouse is different from human and, particularly, in regard to the blood supply of the septum. (B) Contrary to previous belief, the septal coronary artery in the mouse is variable in origin. (C) A constant ligation of the LAD immediately below the left auricular level ensures a statistically significant reproducible infarct size. (D) The ischemic changes can be monitored at a histological level in a way similar to what is described in the human. Conclusion: We illustrate a method for maximal reproducibility of experimental acute myocardial infarction in the mouse model, due to a consistent loss of perfusion in the lower half of the left ventricle. This will allow the study of molecular and physiological variables in a controlled and quantifiable experimental model environment. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Barrett's oesophagus (BO) is a well recognized precursor of the majority of cases of oesophageal adenocarcinoma (OAC). Endoscopic surveillance of BO patients is frequently undertaken in an attempt to detect early OAC, high grade dysplasia (HGD) or low grade dysplasia (LGD). However histological interpretation and grading of dysplasia is subjective and poorly reproducible. The alternative flow cytometry and cytology-preparation image cytometry techniques require large amounts of tissue and specialist expertise which are not widely available for frontline health care.
Methods: This study has combined whole slide imaging with DNA image cytometry, to provide a novel method for the detection and quantification of abnormal DNA contents. 20 cases were evaluated, including 8 Barrett's specialised intestinal metaplasia (SIM), 6 LGD and 6 HGD. Feulgen stained oesophageal sections (1µm thickness) were digitally scanned in their entirety and evaluated to select regions of interests and abnormalities. Barrett’s mucosa was then interactively chosen for automatic nuclei segmentation where irrelevant cell types are ignored. The combined DNA content histogram for all selected image regions was then obtained. In addition, histogram measurements, including 5c exceeding ratio (xER-5C), 2c deviation index (2cDI) and DNA grade of malignancy (DNA-MG), were computed.
Results: The histogram measurements, xER-5C, 2cDI and DNA-MG, were shown to be effective in differentiating SIM from HGD, SIM from LGD, and LGD from HGD. All three measurements discriminated SIM from HGD cases successfully with statistical significance (pxER-5C=0.0041, p2cDI=0.0151 and pDNA-MG=0.0057). Statistical significance is also achieved differentiating SIM from LGD samples with pxER-5C=0.0019, p2cDI=0.0023 and pDNA-MG=0.0030. Furthermore the differences between LGD and HGD cases are statistical significant (pxER-5C=0.0289, p2cDI=0.0486 and pDNA-MG=0.0384).
Conclusion: Whole slide image cytometry is a novel and effective method for the detection and quantification of abnormal DNA content in BO. Compared to manual histological review, this proposed method is more objective and reproducible. Compared to flow cytometry and cytology-preparation image cytometry, the current method is low cost, simple to use and only requires a single 1µm tissue section. Whole slide image cytometry could assist the routine clinical diagnosis of dysplasia in BO, which is relevant for future progression risk to OAC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A highly sensitive broad specificity monoclonal antibody was produced and characterised for microcystin detection through the development of a rapid surface plasmon resonance (SPR) optical biosensor based immunoassay. The antibody displayed the following cross-reactivity: MC-LR 100%; MC-RR 108%; MC-YR 68%; MC-LA 69%; MC-LW 71%; MC-LF 68%; and Nodularin 94%. Microcystin-LR was covalently attached to a CM5 chip and with the monoclonal antibody was employed in a competitive 4min injection assay to detect total microcystins in water samples below the WHO recommended limit (1µg/L). A 'total microcystin' level was determined by measuring free and intracellular concentrations in cyanobacterial culture samples as this toxin is an endotoxin. Glass bead beating was used to lyse the cells as a rapid extraction procedure. This method was validated according to European Commission Decision 96/23/EC criteria. The method was proven to measure intracellular microcystin levels, the main source of the toxin, which often goes undetected by other analytical procedures and is advantageous in that it can be used for the monitoring of blooms to provide an early warning of toxicity. It was shown to be repeatable and reproducible, with recoveries from spiked samples ranging from 74 to 123%, and had % CVs below 10% for intra-assay analysis and 15% for inter-assay analysis. The detection capability of the assay was calculated as 0.5ng/mL for extracellular toxins and 0.05ng/mL for intracellular microcystins. A comparison of the SPR method with LC-MS/MS was achieved by testing six Microcystis aeruginosa cultures and this study yielded a correlation R(2) value of 0.9989.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gene therapy has the potential to provide safe and targeted therapies for a variety of diseases. A range of intracellular gene delivery vehicles have been proposed for this purpose. Non-viral vectors are a particularly attractive option and among them cationic peptides have emerged as promising candidates. For the pharmaceutical formulation and application to clinical studies it is necessary to quantify the amount of pDNA condensed with the delivery system. There is a severe deficiency in this area, thus far no methods have been reported specifically for pDNA condensed with cationic peptide to form nanoparticles. The current study seeks to address this and describes the evaluation of a range of disruption agents to extract DNA from nanoparticles formed by condensation with cationic fusogenic peptides RALA and KALA. Only proteinase K exhibited efficient and reproducible results and compatibility with the PicoGreen reagent based quantification assay. Thus we report for the first time a simple and reliable method that can quantify the pDNA content in pDNA cationic peptide nanoparticles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background

]In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of ensuring the accuracy of linac mechanical performance.


Methods

The Varian EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in MLC carriages as a result of linac rotation were separately investigated by acquisition of EPID images of a simple phantom comprised of 5 ball-bearings during arc delivery. A fast and robust software package was developed for automated analysis of image data. Twelve Varian linacs of different models were investigated.


Results

The average EPID sag was within 1 mm for all tested linacs. All machines showed less than 1 mm gantry sag. Changes in SDD values were within 1.7 mm except for three linacs of one centre which were within 9 mm. Values of EPID skewness and tilt were negligible in all tested linacs. The maximum sag in MLC leaf bank assemblies was around 1 mm. The EPID sag showed a considerable improvement in TrueBeam linacs.


Conclusion

The methodology and software developed in this study provide a simple tool for effective investigation of the behaviour of linac components with gantry rotation. It is reproducible and accurate and can be easily performed as a routine test in clinics.




Relevância:

30.00% 30.00%

Publicador:

Resumo:

Currently there is no reliable objective method to quantify the setting properties of acrylic bone cements within an operating theatre environment. Ultrasonic technology can be used to determine the acoustic properties of the polymerising bone cement, which are linked to material properties and provide indications of the physical and chemical changes occurring within the cement. The focus of this study was the critical evaluation of pulse-echo ultrasonic test method in determining the setting and mechanical properties of three different acrylic bone cement when prepared under atmospheric and vacuum mixing conditions. Results indicated that the ultrasonic pulse-echo technique provided a highly reproducible and accurate method of monitoring the polymerisation reaction and indicating the principal setting parameters when compared to ISO 5833 standard, irrespective of the acrylic bone cement or mixing method used. However, applying the same test method to predict the final mechanical properties of acrylic bone cement did not prove a wholly accurate approach. Inhomogeneities within the cement microstructure and specimen geometry were found to have a significant influence on mechanical property predictions. Consideration of all the results suggests that the non-invasive and non-destructive pulse-echo ultrasonic test method is an effective and reliable method for following the full polymerisation reaction of acrylic bone cement in real-time and then determining the setting properties within a surgical theatre environment. However the application of similar technology for predicting the final mechanical properties of acrylic bone cement on a consistent basis may prove difficult.