24 resultados para Perfusion-weighted electroencephalography
Resumo:
It is shown, for a bounded weighted bilateral shift T acting on l(p)(Z), and for 1
Resumo:
Objectives:
We studied whether an increase in adenosine dose overcomes caffeine antagonism on adenosine-mediated coronary vasodilation.
Background:
Caffeine is a competitive antagonist at the adenosine receptors, but it is unclear whether caffeine in coffee alters the actions of exogenous adenosine, and whether the antagonism can be surmounted by increasing the adenosine dose.
Methods:
Myocardial perfusion scintigraphy (MPS) was used to assess adenosine-induced hyperemia in 30 patients before (baseline) and after coffee ingestion (caffeine). At baseline, patients received 140 µg/kg/min of adenosine combined with low-level exercise. For the caffeine study, 12 patients received 140 µg/kg/min of adenosine (standard) and 18 patients received 210 µg/kg/min (high dose) after caffeine intake (200 mg). Myocardial perfusion was assessed semiquantitatively and quantitatively, and perfusion defect was characterized according to the presence of reversibility.
Results:
Caffeine reduced the magnitude of perfusion abnormality induced by standard adenosine as measured by the summed difference score (SDS) (12.0 ± 4.4 at baseline vs. 4.1 ± 2.1 after caffeine, p < 0.001) as well as defect size (18% [3% to 38%] vs. 8% [0% to 22%], p < 0.01), whereas it had no effect on the abnormalities caused by high-dose adenosine (SDS, 7.7 ± 4.0 at baseline vs. 7.8 ± 4.2 after caffeine, p = 0.7). There was good agreement between baseline and caffeine studies for segmental defect category (kappa = 0.72, 95% confidence interval: 0.65 to 0.79) in the high-dose group. An increase in adenosine after caffeine intake was well tolerated.
Conclusions:
Caffeine in coffee attenuates adenosine-induced coronary hyperemia and, consequently, the detection of perfusion abnormality by adenosine MPS. This can be overcome by increasing the adenosine dose without compromising test tolerability.
Resumo:
A ranking method assigns to every weighted directed graph a (weak) ordering of the nodes. In this paper we axiomatize the ranking method that ranks the nodes according to their outflow using four independent axioms. Besides the well-known axioms of anonymity and positive responsiveness we introduce outflow monotonicity – meaning that in pairwise comparison between two nodes, a node is not doing worse in case its own outflow does not decrease and the other node’s outflow does not increase – and order preservation – meaning that adding two weighted digraphs such that the pairwise ranking between two nodes is the same in both weighted digraphs, then this is also their pairwise ranking in the ‘sum’ weighted digraph. The outflow ranking method generalizes the ranking by outdegree for directed graphs, and therefore also generalizes the ranking by Copeland score for tournaments.
Resumo:
We introduce three compact graph states that can be used to perform a measurement-based Toffoli gate. Given a weighted graph of six, seven, or eight qubits, we show that success probabilities of 1/4, 1/2, and 1, respectively, can be achieved. Our study puts a measurement-based version of this important quantum logic gate within the reach of current experiments. As the graphs are setup independent, they could be realized in a variety of systems, including linear optics and ion traps.
Resumo:
Background: We investigated if minimizing bowel manipulation and mesenteric traction using the retroperitoneal approach in open abdominal aortic aneurysm (AAA) repair preserves splanchnic perfusion, as measured by gastric tonometry, and reduces the systemic inflammatory response and dysfunction of the various organs.