34 resultados para Pen and Pencil Club.
Resumo:
The relative biological effectiveness (RBE) of passive scattered (PS) and pencil beam scanned (PBS) proton beam delivery techniques for uniform beam configurations was determined by clonogenic survival. The radiobiological impact of modulated beam configurations on cell survival occurring in- or out-of-field for both delivery techniques was determined with intercellular communication intact or physically inhibited. Cell survival responses were compared to those observed using a 6 MV photon beam produced with a linear accelerator. DU-145 cells showed no significant difference in survival response to proton beams delivered by PS and PBS or 6 MV photons taking into account a RBE of 1.1 for protons at the centre of the spread out Bragg peak. Significant out-of-field effects similar to those observed for 6 MV photons were observed for both PS and PBS proton deliveries with cell survival decreasing to 50-60% survival for scattered doses of 0.05 and 0.03 Gy for passive scattered and pencil beam scanned beams respectively. The observed out-of-field responses were shown to be dependent on intercellular communication between the in-and out-of-field cell populations. These data demonstrate, for the first time, a similar RBE between passive and actively scanned proton beams and confirm that out-of-field effects may be important determinants of cell survival following exposure to modulated photon and proton fields
Resumo:
OBJECTIVE:
To compare the performance of patients with mild-moderate Alzheimer's disease (AD) and vascular dementia (VaD) on tests of information processing and attention.
METHOD:
Patients with AD (n=75) and VaD (n=46) were recruited from a memory clinic along with dementia-free participants (n=28). They underwent specific tests of attention from the Cognitive Drug Research battery, and pen and paper tests including Colour Trails A and B and Stroop. All patients had a CT brain scan that was independently scored for white-matter change/ischaemia.
RESULTS:
Attention was impaired in both AD and VaD patients. VaD patients had more impaired choice reaction times and were less accurate on a vigilance test measuring sustained attention. Deficits in selective and divided attention occurred in both patient groups and showed the strongest correlations with Mini Mental State Examination scores.
CONCLUSION:
This study demonstrates problems with the attentional network in mild-moderate AD and VaD. The authors propose that attention should be tested routinely in a memory clinic setting.
Resumo:
Objective: To compare performance of patients with mild-moderate Alzheimer's disease (AD) and vascular dementia (VaD) on tests of executive functioning and working memory.
Methods: Patients with AD (n = 76) and VaD (n = 46) were recruited from a memory clinic along with dementia free participants (n = 28). They underwent specific tests of working memory from the Cognitive Drug Research (CDR) battery and pen and paper tests of executive function including CLOX 1 & 2, EXIT25 and a test of verbal fluency (COWAT). All patients had a CT brain scan which was independently scored for white matter change/ischaemia.
Results: The AD and VaD groups were significantly impaired on all measures of working memory and executive functioning compared to the disease free group. There were no significant differences between the AD and VaD groups on any measure. Z-scores confirmed the pattern of impairment in executive functioning and working memory was largely equivalent in both patient groups. Small to moderate correlations were seen between the MMSE and the neurocognitive scores in both patient groups and the pattern of correlations was also very similar in both patient groups.
Conclusions: This study demonstrates sizeable executive functioning and working memory impairments in patients with mild-moderate AD and VaD but no significant differences between the disease groups. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
The apolipoprotein (APOE) epsilon4 allele is a genetic risk factor for the development of Alzheimer's disease (AD). It has also been associated with vascular dementia (VaD) in some but not all studies. Previous studies have examined the role of APOE in predicting performance on cognitive tests in both demented and non-demented populations. In cognitively intact individuals, statistically significant group differences between APOE epsilon4 carriers and non-carriers have been demonstrated for several cognitive domains. In AD studies of the impact of APOE epsilon4 on cognition have been conflicting while no previous study has assessed cognition and impact of APOE epsilon4 in VaD. In this study we investigated the impact of APOE epsilon4 on performance in neuropsychological tests including information processing speed in patients with mild-moderate AD and VaD. We incorporated both computerized and pen and paper tests to ensure a sensitive method of assessing cognition. 109 patients participated in the study (VaD=41, AD=68). Neurocognitive performance of 44 epsilon4 present AD patients was compared to 24 epsilon4absent patients and performance of 23 epsilon4 present VaD patients was compared to 18 epsilon4 absent patients. There was evidence that APOE epsilon4 conferred a risk of poorer cognitive functioning in both patient groups. In the AD group presence of epsilon4 conferred a negative impact on some measures of speed of information processing and immediate recall while in the VaD group epsilon4 present patients had evidence of poorer accuracy on tasks such as choice reaction time and spatial working memory. In AD and VaD groups epsilon4 present patients showed impairment in selective attention. These findings provide further support of the negative impact of the epsilon4 allele in cognition.
Resumo:
Although consumer perception of the health claims and nutrition information has been studied widely there is relatively little understanding about the motivational factors underpinning claim perception. The objective of this study is to investigate how levels of perceived relevance influence consumers’ responses to health claims that either promise to reduce a targeted disease risk or improve well-being in comparison to other types of health-related messages, and how attitudes towards nutritionally healthy eating, functional food and previous experience relating to products with health claims affect the consumers’ perceptions of nutrition and health claims. The data (N=2385) were collected by paper and pencil surveys in Finland, the UK, Germany and Italy on a target group of consumers over 35 year old, solely or jointly responsible for the family’s food shopping. The results showed that relevance has a strong influence on perceptions of personal benefit and willingness to buy products with health claims. However the impact of relevance is much stronger when the health risks are relevant to self than when it is relevant to those close to oneself, especially when the claim promises a targeted risk reduction with detailed information about function and health outcome. Previous experience with products with health claims and interest in nutritionally healthy eating promoted the utility of all claims, regardless of whether they were health or nutrition claims. However, to be influenced by health claims consumers also need to have a positive attitude towards functional food products.
Resumo:
Water-based colourimetric indicator films are shown to have increased operational lifetimes under ambient conditions compared to similar solvent-based counterparts. The response and sensitivity characteristics of a water-based, carbon dioxide-responsive ink are characterised and compared and contrasted to those of a similar solvent-based indicator. The changes in the response characteristics of the ink as a function of the amount of base (sodium hydrogen carbonate) and plasticizer (glycerol) contained in the ink are reported, as are the effects of varying ambient temperature and humidity. The ink is incorporated into a felt tip pen and applied to a number of different substrates, producing a distinct, reversible colour change on all tested surfaces, when a sufficient level of carbon dioxide is present. The possible application of the indicator is discussed briefly.
Resumo:
The effect of nonconservative current-induced forces on the ions in a defect-free metallic nanowire is investigated using both steady-state calculations and dynamical simulations. Nonconservative forces were found to have a major influence on the ion dynamics in these systems, but their role in increasing the kinetic energy of the ions decreases with increasing system length. The results illustrate the importance of nonconservative effects in short nanowires and the scaling of these effects with system size. The dependence on bias and ion mass can be understood with the help of a simple pen and paper model. This material highlights the benefit of simple preliminary steady-state calculations in anticipating aspects of brute-force dynamical simulations, and provides rule of thumb criteria for the design of stable quantum wires.
Resumo:
Dynamical effects of non-conservative forces in long, defect free atomic wires are investigated. Current flow through these wires is simulated and we find that during the initial transient, the kinetic energies of the ions are contained in a small number of phonon modes, closely clustered in frequency. These phonon modes correspond to the waterwheel modes determined from preliminary static calculations. The static calculations allow one to predict the appearance of non-conservative effects in advance of the more expensive real-time simulations. The ion kinetic energy redistributes across the band as non-conservative forces reach a steady state with electronic factional forces. The typical ion kinetic energy is found to decrease with system length, increase with atomic mass, and its dependence on bias, mass and length is supported with a pen and paper model. This paper highlights the importance of non-conservative forces in current carrying devices and provides criteria for the design of stable atomic wires.
Resumo:
The object of this work is to assess the suitability of metallocene catalyzed linear low-density polyethylenes for the rotational molding of foams and to link the material and processing conditions to cell morphology and part mechanical properties (flexural and compressive strength). Through adjustments to molding conditions, the significant processing and physical material parameters that optimize metallocene catalyzed linear low-density polyethylene foam structure have been identified. The results obtained from an equivalent conventional grade of Ziegler-Natta catalyzed linear low-density polyethylene are used as a basis for comparison. The key findings of this study are that metallocene catalyzed LLDPE can be used in rotational foam molding to produce a foam that will perform as well as a ZieglerNatta catalyzed foam and that foam density Is by far the most Influential factor over mechanical properties of foam. © 2004 Society of Plastics Engineers.