6 resultados para PCR clone isolation method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective
Scant evidence is available on the discordance between loneliness and social isolation among older adults. We aimed to investigate this discordance and any health implications that it may have.

Method
Using nationally representative datasets from ageing cohorts in Ireland (TILDA) and England (ELSA), we created a metric of discordance between loneliness and social isolation, to which we refer as Social Asymmetry. This metric was the categorised difference between standardised scores on a scale of loneliness and a scale of social isolation, giving categories of: Concordantly Lonely and Isolated, Discordant: Robust to Loneliness, or Discordant: Susceptible to Loneliness. We used regression and multilevel modelling to identify potential relationships between Social Asymmetry and cognitive outcomes.

Results
Social Asymmetry predicted cognitive outcomes cross-sectionally and at a two-year follow-up, such that Discordant: Robust to Loneliness individuals were superior performers, but we failed to find evidence for Social Asymmetry as a predictor of cognitive trajectory over time.

Conclusions
We present a new metric and preliminary evidence of a relationship with clinical outcomes. Further research validating this metric in different populations, and evaluating its relationship with other outcomes, is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Philippines has a population of approximately 103 million people, of which 6.7 million live in schistosomiasis-endemic areas with 1.8 million people being at risk of infection with Schistosoma japonicum. Although the country-wide prevalence of schistosomiasis japonica in the Philippines is relatively low, the prevalence of schistosomiasis can be high, approaching 65% in some endemic areas. Of the currently available microscopy-based diagnostic techniques for detecting schistosome infections in the Philippines and elsewhere, most exhibit varying diagnostic performances, with the Kato-Katz (KK) method having particularly poor sensitivity for detecting low intensity infections. This suggests that the actual prevalence of schistosomiasis japonica may be much higher than previous reports have indicated.

METHODOLOGY/PRINCIPAL FINDINGS: Six barangay (villages) were selected to determine the prevalence of S. japonicum in humans in the municipality of Palapag, Northern Samar. Fecal samples were collected from 560 humans and examined by the KK method and a validated real-time PCR (qPCR) assay. A high S. japonicum prevalence (90.2%) was revealed using qPCR whereas the KK method indicated a lower prevalence (22.9%). The geometric mean eggs per gram (GMEPG) determined by the qPCR was 36.5 and 11.5 by the KK. These results, particularly those obtained by the qPCR, indicate that the prevalence of schistosomiasis in this region of the Philippines is much higher than historically reported.

CONCLUSIONS/SIGNIFICANCE: Despite being more expensive, qPCR can complement the KK procedure, particularly for surveillance and monitoring of areas where extensive schistosomiasis control has led to low prevalence and intensity infections and where schistosomiasis elimination is on the horizon, as for example in southern China.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Droplet digital PCR (ddPCR) can be used to detect low frequency mutations in oncogene-driven lung cancer. The range of KRAS point mutations observed in NSCLC necessitates a multiplex approach to efficient mutation detection in circulating DNA. Here we report the design and optimisation of three discriminatory ddPCR multiplex assays investigating nine different KRAS mutations using PrimePCR™ ddPCR™ Mutation Assays and the Bio-Rad QX100 system. Together these mutations account for 95% of the nucleotide changes found in KRAS in human cancer. Multiplex reactions were optimised on genomic DNA extracted from KRAS mutant cell lines and tested on DNA extracted from fixed tumour tissue from a cohort of lung cancer patients without prior knowledge of the specific KRAS genotype. The multiplex ddPCR assays had a limit of detection of better than 1 mutant KRAS molecule in 2,000 wild-type KRAS molecules, which compared favourably with a limit of detection of 1 in 50 for next generation sequencing and 1 in 10 for Sanger sequencing. Multiplex ddPCR assays thus provide a highly efficient methodology to identify KRAS mutations in lung adenocarcinoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monitoring multiple myeloma patients for relapse requires sensitive methods to measure minimal residual disease and to establish a more precise prognosis. The present study aimed to standardize a real-time quantitative polymerase chain reaction (PCR) test for the IgH gene with a JH consensus self-quenched fluorescence reverse primer and a VDJH or DJH allele-specific sense primer (self-quenched PCR). This method was compared with allele-specific real-time quantitative PCR test for the IgH gene using a TaqMan probe and a JH consensus primer (TaqMan PCR). We studied nine multiple myeloma patients from the Spanish group treated with the MM2000 therapeutic protocol. Self-quenched PCR demonstrated sensitivity of >or=10(-4) or 16 genomes in most cases, efficiency was 1.71 to 2.14, and intra-assay and interassay reproducibilities were 1.18 and 0.75%, respectively. Sensitivity, efficiency, and residual disease detection were similar with both PCR methods. TaqMan PCR failed in one case because of a mutation in the JH primer binding site, and self-quenched PCR worked well in this case. In conclusion, self-quenched PCR is a sensitive and reproducible method for quantifying residual disease in multiple myeloma patients; it yields similar results to TaqMan PCR and may be more effective than the latter when somatic mutations are present in the JH intronic primer binding site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a European BIOMED-2 collaborative study, multiplex PCR assays have successfully been developed and standardized for the detection of clonally rearranged immunoglobulin (Ig) and T-cell receptor (TCR) genes and the chromosome aberrations t(11;14) and t(14;18). This has resulted in 107 different primers in only 18 multiplex PCR tubes: three VH-JH, two DH-JH, two Ig kappa (IGK), one Ig lambda (IGL), three TCR beta (TCRB), two TCR gamma (TCRG), one TCR delta (TCRD), three BCL1-Ig heavy chain (IGH), and one BCL2-IGH. The PCR products of Ig/TCR genes can be analyzed for clonality assessment by heteroduplex analysis or GeneScanning. The detection rate of clonal rearrangements using the BIOMED-2 primer sets is unprecedentedly high. This is mainly based on the complementarity of the various BIOMED-2 tubes. In particular, combined application of IGH (VH-JH and DH-JH) and IGK tubes can detect virtually all clonal B-cell proliferations, even in B-cell malignancies with high levels of somatic mutations. The contribution of IGL gene rearrangements seems limited. Combined usage of the TCRB and TCRG tubes detects virtually all clonal T-cell populations, whereas the TCRD tube has added value in case of TCRgammadelta(+) T-cell proliferations. The BIOMED-2 multiplex tubes can now be used for diagnostic clonality studies as well as for the identification of PCR targets suitable for the detection of minimal residual disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to develop a multiplex loop-mediated isothermal amplification (LAMP) method capable of detecting Escherichia coli generally and verocytotoxigenic E. coli (VTEC) specifically in beef and bovine faeces. The LAMP assay developed was highly specific (100%) and able to distinguish between E. coli and VTEC based on the amplification of the phoA, and stx1 and/or stx2 genes, respectively. In the absence of an enrichment step, the limit of detection 50% (LOD50) of the LAMP assay was determined to be 2.83, 3.17 and 2.83-3.17 log CFU/g for E. coli with phoA, stx1 and stx2 genes, respectively, when artificially inoculated minced beef and bovine faeces were tested. The LAMP calibration curves generated with pure cultures, and spiked beef and faeces, suggested that the assay had good quantification capability. Validation of the assay, performed using retail beef and bovine faeces samples, demonstrated good correlation between counts obtained by the LAMP assay and by a conventional culture method, but suggested the possibility of false negative LAMP results for 12.5-14.7% of samples tested. The multiplex LAMP assay developed potentially represents a rapid alternative to culture for monitoring E.coli levels in beef or faeces and it would provide additional information on the presence of VTEC. However, some further optimisation is needed to improve detection sensitivity.