13 resultados para Oxygen therapy.
Resumo:
BACKGROUND: Although pneumonia is a common cause of death in children in Malawi, healthcare staff frequently encounter patients or carers who refuse oxygen therapy. This qualitative study documents factors that influence acceptance or refusal of oxygen therapy for children in Malawi.
METHODS: Nine group interviews involving 86 participants were held in community and hospital settings in rural and urban Malawi. Eleven in-depth interviews of healthcare staff providing oxygen were held in a central hospital. Thematic analysis of transcripts of the audio recordings was carried out to identify recurring themes.
RESULTS: Similar ideas were identified in the group interviews and in-depth staff interviews. Past experiences of oxygen use (direct and indirect, positive and negative) had a strong influence on views of oxygen. A recurrent theme was fear of oxygen, often due to a perceived association between death and recent oxygen use. Fears were intensified by a lack of familiarity with equipment used to deliver oxygen, distrust of medical staff and concerns about cost of oxygen.
CONCLUSIONS: This study identifies reasons for refusal of oxygen therapy for children in a low-income country. Findings from the study suggest that training of healthcare staff to address fears of parents, and information, education and communication (IEC) approaches that improve public understanding of oxygen and provide positive examples of its use are likely to be helpful in improving uptake of oxygen therapy in Malawi.
Resumo:
This study aims to explore the potential for palliative care among people living with advanced chronic obstructive pulmonary disease (COPD). Individual semi-structured interviews (n=13) were conducted with people who had a diagnosis of advanced COPD and were on optimal tolerated drug therapy, with their breathing volume (forced expiratory volume at less than 30%) or were on long-term oxygen therapy or non-invasion ventilation. Participants raised concerns about the uncertain trajectory of the illness and reported unmet palliative care needs with poor access to palliative care services. For most people, palliative care was associated with end of life; therefore, they were unwilling to discuss the issue. There was a wide acceptance that, medically, nothing more could be done. Findings also suggest that patients had unmet palliative care needs, requiring information and support. The research suggests the need for palliative care to be extended to all (regardless of diagnosis), with packages of care developed to target specific needs.
Resumo:
Only long-term home oxygen therapy has been shown in randomised controlled trials to increase survival in chronic obstructive pulmonary disease (COPD). There have been no trials assessing the effect of inhaled corticosteroids and long-acting bronchodilators, alone or in combination, on mortality in patients with COPD, despite their known benefit in reducing symptoms and exacerbations. The "TOwards a Revolution in COPD Health" (TORCH) survival study is aiming to determine the impact of salmeterol/fluticasone propionate (SFC) combination and the individual components on the survival of COPD patients. TORCH is a multicentre, randomised, double-blind, parallel-group, placebo-controlled study. Approximately 6,200 patients with moderate-to-severe COPD were randomly assigned to b.i.d. treatment with either SFC (50/500 microg), fluticasone propionate (500 microg), salmeterol (50 microg) or placebo for 3 yrs. The primary end-point is all-cause mortality; secondary end-points are COPD morbidity relating to rate of exacerbations and health status, using the St George's Respiratory Questionnaire. Other end-points include other mortality and exacerbation end-points, requirement for long-term oxygen therapy, and clinic lung function. Safety end-points include adverse events, with additional information on bone fractures. The first patient was recruited in September 2000 and results should be available in 2006. This paper describes the "TOwards a Revolution in COPD Health" study and explains the rationale behind it.
Resumo:
Non-invasive ventilation may be a means to temporarily reverse or slow the progression of respiratory failure in cystic fibrosis. To compare the effect of non-invasive ventilation versus no non-invasive ventilation in people with cystic fibrosis. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches, handsearching relevant journals and abstract books of conference proceedings. We searched the reference lists of each trial for additional publications possibly containing other trials.Most recent search: 22 February 2013. Randomised controlled trials comparing a form of pressure preset or volume preset non-invasive ventilation to no non-invasive ventilation in people with acute or chronic respiratory failure in cystic fibrosis. Three reviewers independently assessed trials for inclusion criteria and methodological quality, and extracted data. Fifteen trials were identified; seven trials met the inclusion criteria with a total of 106 participants. Six trials evaluated single treatment sessions and one evaluated a six-week intervention.Four trials (79 participants) evaluated non-invasive ventilation for airway clearance compared with an alternative chest physiotherapy method and showed that airway clearance may be easier with non-invasive ventilation and people with cystic fibrosis may prefer it. We were unable to find any evidence that NIV increases sputum expectoration, but it did improve some lung function parameters.Three trials (27 participants) evaluated non-invasive ventilation for overnight ventilatory support, measuring lung function, validated quality of life scores and nocturnal transcutaneous carbon dioxide. Due to the small numbers of participants and statistical issues, there were discrepancies in the results between the RevMan and the original trial analyses. No clear differences were found between non-invasive ventilation compared with oxygen or room air except for exercise performance, which significantly improved with non-invasive ventilation compared to room air over six weeks. Non-invasive ventilation may be a useful adjunct to other airway clearance techniques, particularly in people with cystic fibrosis who have difficulty expectorating sputum. Non-invasive ventilation, used in addition to oxygen, may improve gas exchange during sleep to a greater extent than oxygen therapy alone in moderate to severe disease. These benefits of non-invasive ventilation have largely been demonstrated in single treatment sessions with small numbers of participants. The impact of this therapy on pulmonary exacerbations and disease progression remain unclear. There is a need for long-term randomised controlled trials which are adequately powered to determine the clinical effects of non-invasive ventilation in cystic fibrosis airway clearance and exercise.
Resumo:
Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design--consumer-grade pumps, medical tubing, and regulators--it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device.
Resumo:
Background: The treatment of solid tumours and angiogenic ocular diseases by photodynamic therapy (PDT) requires the injection of a photosensitiser (PS) to destroy target cells through a combination of visible light irradiation and molecular oxygen. There is currently great interest in the development of efficient and specific carrier delivery platforms for systemic PDT. Objective: This article aims to review recent developments in systemic carrier delivery platforms for PDT, with an emphasis on target specificity. Methods: Recent publications, spanning the last five years, concerning delivery carrier platforms for systemic PDT were reviewed, including PS conjugates, dendrimers, micelles, liposomes and nanoparticles. Results/conclusion: PS conjugates and supramolecular delivery platforms can improve PDT selectivity by exploiting cellular and physiological specificities of the targeted tissue. Overexpression of receptors in cancer and angiogenic endothelial cells allows their targeting by affinity-based moieties for the selective uptake of PS conjugates and encapsulating delivery carriers, while the abnormal tumour neovascularisation induces a specific accumulation of heavy weighted PS carriers by enhanced permeability and retention (EPR) effect. in addition, polymeric prodrug delivery platforms triggered by the acidic nature of the tumour environment or the expression of proteases can be designed. Promising results obtained with recent systemic carrier platforms will, in due course, be translated into the clinic for highly efficient and selective PDT protocols.
Resumo:
Despite the critical role of Epidermal Growth Factor Receptor (EGFR) in glioblastoma pathogenesis [1,2], EGFR targeted therapies have achieved limited clinical efficacy [3]. Here we propose an alternate therapeutic strategy based on the conceptual framework of non-oncogene addiction [4,5]. A directed RNAi screen revealed that glioblastoma cells overexpressing EGFRvIII [6], an oncogenic variant of EGFR, become hyper-dependent on a variety of DNA repair genes. Among these, there was an enrichment of Base Excision Repair (BER) genes required for the repair of Reactive Oxygen Species (ROS)-induced DNA damage, including poly-ADP ribose polymerase 1 (PARP1). Subsequent studies revealed that EGFRvIII overexpression in glioblastoma cells caused increased levels of ROS, DNA strand break accumulation, and genome instability. In a panel of primary glioblastoma lines, sensitivity to PARP1 inhibition correlated with the levels of EGFR activation and oxidative stress. Gene expression analysis indicated that reduced expression of BER genes in glioblastomas with high EGFR expression correlated with improved patient survival. These observations suggest that oxidative stress secondary to EGFR hyperactivation necessitates increased cellular reliance on PARP1 mediated BER, and offer critical insights into clinical trial design.
Resumo:
Introduction: The application of light as a stimulus in pharmaceutical systems and the associated ability to provide precise spatiotemporal control over location, wavelength and intensity, allowing ease of external control independent of environmental conditionals, has led to its increased use. Of particular note is the use of light with photosensitisers.
Areas covered: Photosensitisers are widely used in photodynamic therapy to cause a cidal effect towards cells on irradiation due to the generation of reactive oxygen species. These cidal effects have also been used to treat infectious diseases. The effects and benefits of photosensitisers in the treatment of such conditions are still being developed and further realised, with the design of novel delivery strategies. This review provides an overview of the realisation of the pharmaceutically relevant uses of photosensitisers, both in the context of current research and in terms of current clinical application, and looks to the future direction of research.
Expert opinion: Substantial advances have been and are being made in the use of photosensitisers. Of particular note are their antimicrobial applications, due to absence of resistance that is so frequently associated with conventional treatments. Their potency of action and the ability to immobilise to polymeric supports is opening a wide range of possibilities with great potential for use in healthcare infection prevention strategies.
Resumo:
Photodynamic therapy and photodynamic antimicrobial chemotherapy are widely used, but despite this, the relationships between fluence, wavelength of irradiation and singlet oxygen (1O2) production are poorly understood. To establish the relationships between these factors in medically-relevant materials, the effect of fluence on 1O2 production from a tetrakis(4-N-methylpyridyl)porphyrin (TMPyP)-incorporated 2-hydroxyethyl methacrylate: methyl methacrylate: methacrylic acid (HEMA:MMA:MAA) copolymer, a total energy of 50.48 J/cm², was applied at varying illumination power, and times. 1O2 production was characterised using anthracene-9,10-dipropionic acid, disodium salt (ADPA) using a recently described method. Using two light sources, a white LED array and a white halogen source, the LED array was found to produce less 1O2 than the halogen source when the same power (over 500-600 nm) and time conditions were applied. Importantly, it showed that the longest wavelength Q band (590 nm) is primarily responsible for 1O2 generation, and that a linear relationship exists between increasing power and time and the production of singlet oxygen.
Resumo:
Photodynamic therapy and photodynamic antimicrobial chemotherapy are widely used, but despite this, the relationships between fluence, wavelength of irradiation and singlet oxygen ((1) O2 ) production are poorly understood. To establish the relationships between these factors in medically relevant materials, the effect of fluence on (1) O2 production from a tetrakis(4-N-methylpyridyl)porphyrin (TMPyP)-incorporated 2-hydroxyethyl methacrylate: methyl methacrylate: methacrylic acid (HEMA: MMA:MAA) copolymer, a total energy of 50.48 J/cm(2) , was applied at varying illumination power, and times. (1) O2 production was characterized using anthracene-9,10-dipropionic acid, disodium salt (ADPA) using a recently described method. Using two light sources, a white LED array and a white halogen source, the LED array was found to produce less (1) O2 than the halogen source when the same power (over 500 - 600 nm) and time conditions were applied. Importantly, it showed that the longest wavelength Q band (590 nm) is primarily responsible for (1) O2 generation, and that a linear relationship exists between increasing power and time and the production of singlet oxygen.
Resumo:
BACKGROUND: A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter.
METHODS: Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies.
RESULTS: There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions.
CONCLUSIONS: A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.