BACKGROUND: Sleep-disordered breathing is a common and serious feature of many paediatric conditions and is particularly a problem in children with Down syndrome. Overnight pulse oximetry is recommended as an initial screening test, but it is unclear how overnight oximetry results should be interpreted and how many nights should be recorded.

METHODS: This retrospective observational study evaluated night-to-night variation using statistical measures of repeatability for 214 children referred to a paediatric respiratory clinic, who required overnight oximetry measurements. This included 30 children with Down syndrome. We measured length of adequate trace, basal SpO2, number of desaturations (>4% SpO2 drop for >10 s) per hour ('adjusted index') and time with SpO2<90%. We classified oximetry traces into normal or abnormal based on physiology.

RESULTS: 132 out of 214 (62%) children had three technically adequate nights' oximetry, including 13 out of 30 (43%) children with Down syndrome. Intraclass correlation coefficient for adjusted index was 0.54 (95% CI 0.20 to 0.81) among children with Down syndrome and 0.88 (95% CI 0.84 to 0.91) for children with other diagnoses. Negative predictor value of a negative first night predicting two subsequent negative nights was 0.2 in children with Down syndrome and 0.55 in children with other diagnoses.

CONCLUSIONS: There is substantial night-to-night variation in overnight oximetry readings among children in all clinical groups undergoing overnight oximetry. This is a more pronounced problem in children with Down syndrome. Increasing the number of attempted nights' recording from one to three provides useful additional clinical information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Idiopathic Erythrocytosis (IE) is a diagnosis given to patients who have an absolute erythrocytosis (red cell mass more than 25% above their mean normal predicted value) but who do not have a known form of primary or secondary erythrocytosis (BCSH guideline, 2005). We report here the results of a follow-up study of 80 patients (44 male and 36 female) diagnosed with IE from the United Kingdom and the Republic of Ireland over a 10 year period. Baseline information was initially collected when investigating for molecular causes of erythrocytosis in this group. The diagnosis of IE was made on the basis of a raised red cell mass >25% above mean normal predicted value, absence of Polycythaemia Vera (PV) based on the criteria of Pearson and Messinezy (1996), and the exclusion of secondary erythrocytosis (oxygen saturation >92% on pulse oximetry, no history of sleep apnoea, no renal or hepatic pathology, and a normal oxygen dissociation curve (if indicated). The average age at diagnosis of erythrocytosis was 34.5 (2–74 years). Erythropoietin levels were available for 77/80 of the patients and were low in 18 (23%) and normal or high in 59 (74%). Ultrasound imaging was carried out in 67 patients (84%) at time of diagnosis and no significant abnormalities found. Fourteen patients had a family history of erythrocytosis. These patients have now been followed up for an average of 9.4 years (range 1–39). Out of 80 patients 56 patients can still be classified as having IE, of whom 52 are living (cause of death in the other 4 - lung cancer, RTA, sepsis, unknown). Thirty-five of these patients are regularly venesected, 3 take hydroxyurea (one also venesected), 11 receive no treatment while treatment is unknown in 2. Twenty take aspirin, 1 warfarin and 31 no thromboprophylaxis. Four of these patients had suffered thromboembolic complications (3 with CVA/TIAs and 1 with recurrent DVT) at or before their original diagnosis. Since diagnosis 8 patients have had 9 thrombotic events of which 7 were arterial (1 CVA, 3 TIAs, 1 MI, 2 PVD) and 2 venous (DVT/PE). Twenty take aspirin, 1 dipyridamole, 1 warfarin and 30 take no thromboprophylaxis. Out of the 24 patients who now have a diagnosis other than IE, 8 have been diagnosed with myelo-proliferative disease. Thirteen patients have a molecular abnormality which is likely to account for their erythrocytosis (11 VHL, 1 PHD-2, 1 EPO-receptor mutations). Three patients have secondary erythrocytosis. Older case studies identified a heterogenous group of patients, some of whom probably had apparent erythrocytosis and some who had either primary polycythaemia or secondary causes later identified (Modan and Modan, Najean et al). More recent reviews have identified a more homogenous group with low rates of transformation to myelofibrosis/acute leukaemia and low rates of thrombosis of around 1% patient-year. Follow up of our initial patient group does indeed reveal a heterogeneous group of patients with 10% now diagnosed with an MPD, although when analysis is confined to those patients who continue to fulfil the criteria for IE, the clinical course has been more stable. There has been no progression to MDS or leukaemia in this group (one patient with PV progressed to AML). The rate of thrombosis is 1.6% patient-years which is lower than the rate seen in PV and is consistent with the rate identified in other series. Molecular defects continue to be identified in this group and future investigation is likely to reveal further abnormalities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Arterial desaturation as measured using pulse oximetry may not reflect cardiorespiratory disease; other possible causes, including certain drugs, should be sought. Within the literature, examples exist of dapsone-induced methaemoglobinaemia causing diagnostic confusion, particularly where respiratory disease is a feature. Few cases have been reported that demonstrate the potential of relatively low levels of methaemoglobinaemia to upset pulse oximetry readings. We describe three examples of dapsone-induced methaemoglobinaemia emphasising the potential for low-grade methaemoglobinaemia to cause diagnostic confusion. Widespread use of the pulse oximeter indicates this problem may occur more regularly, hence there is a need for increased awareness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter.

METHODS: Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies.

RESULTS: There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions.

CONCLUSIONS: A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.