5 resultados para Output-only Modal Analysis
Resumo:
An analysis of the operation of a new series-L/parallel-tuned Class-E amplifier and its equivalence to the classic shunt-C/series-tuned Class-E amplifier are presented. The first reported closed form design equations for the series-L/parallel-tuned topology operating under ideal switching conditions are given, including the switch current and voltage in steady state, the circuit component values, the peak values of switch current and voltage and the power-output capability. Theoretical analysis is confirmed by numerical simulation for a 500 mW (27 dBm), 10% bandwidth, 5 V series-L/parallel-tuned, then, shunt-C/series-tuned Class-E power amplifier, operating at 2.5 GHz. Excellent agreement between theory and simulation results is achieved.
Resumo:
With the main focus on safety, design of structures for vibration serviceability is often overlooked or mismanaged, resulting in some high profile structures failing publicly to perform adequately under human dynamic loading due to walking, running or jumping. A standard tool to inform better design, prove fitness for purpose before entering service and design retrofits is modal testing, a procedure that typically involves acceleration measurements using an array of wired sensors and force generation using a mechanical shaker. A critical but often overlooked aspect is using input (force) to output (response) relationships to enable estimation of modal mass, which is a key parameter directly controlling vibration levels in service.
This paper describes the use of wireless inertial measurement units (IMUs), designed for biomechanics motion capture applications, for the modal testing of a 109 m footbridge. IMUs were first used for an output-only vibration survey to identify mode frequencies, shapes and damping ratios, then for simultaneous measurement of body accelerations of a human subject jumping to excite specific vibrations modes and build up bridge deck accelerations at the jumping location. Using the mode shapes and the vertical acceleration data from a suitable body landmark scaled by body mass, thus providing jumping force data, it was possible to create frequency response functions and estimate modal masses.
The modal mass estimates for this bridge were checked against estimates obtained using an instrumented hammer and known mass distributions, showing consistency among the experimental estimates. Finally, the method was used in an applied research application on a short span footbridge where the benefits of logistical and operational simplicity afforded by the highly portable and easy to use IMUs proved extremely useful for an efficient evaluation of vibration serviceability, including estimation of modal masses.
Resumo:
Background The use of simulation in medical education is increasing, with students taught and assessed using simulated patients and manikins. Medical students at Queen’s University of Belfast are taught advanced life support cardiopulmonary resuscitation as part of the undergraduate curriculum. Teaching and feedback in these skills have been developed in Queen’s University with high-fidelity manikins. This study aimed to evaluate the effectiveness of video compared to verbal feedback in assessment of student cardiopulmonary resuscitation performance Methods Final year students participated in this study using a high-fidelity manikin, in the Clinical Skills Centre, Queen’s University Belfast. Cohort A received verbal feedback only on their performance and cohort B received video feedback only. Video analysis using ‘StudioCode’ software was distributed to students. Each group returned for a second scenario and evaluation 4 weeks later. An assessment tool was created for performance assessment, which included individual skill and global score evaluation. Results One hundred thirty eight final year medical students completed the study. 62 % were female and the mean age was 23.9 years. Students having video feedback had significantly greater improvement in overall scores compared to those receiving verbal feedback (p = 0.006, 95 % CI: 2.8–15.8). Individual skills, including ventilation quality and global score were significantly better with video feedback (p = 0.002 and p < 0.001, respectively) when compared with cohort A. There was a positive change in overall score for cohort B from session one to session two (p < 0.001, 95 % CI: 6.3–15.8) indicating video feedback significantly benefited skill retention. In addition, using video feedback showed a significant improvement in the global score (p < 0.001, 95 % CI: 3.3–7.2) and drug administration timing (p = 0.004, 95 % CI: 0.7–3.8) of cohort B participants, from session one to session two. Conclusions There is increased use of simulation in medicine but a paucity of published data comparing feedback methods in cardiopulmonary resuscitation training. Our study shows the use of video feedback when teaching cardiopulmonary resuscitation is more effective than verbal feedback, and enhances skill retention. This is one of the first studies to demonstrate the benefit of video feedback in cardiopulmonary resuscitation teaching.
Resumo:
A field experiment was conducted on a real continuous steel Gerber-truss bridge with artificial damage applied. This article summarizes the results of the experiment for bridge damage detection utilizing traffic-induced vibrations. It investigates the sensitivities of a number of quantities to bridge damage including the identified modal parameters and their statistical patterns, Nair’s damage indicator and its statistical pattern and different sets of measurement points. The modal parameters are identified by autoregressive time-series models. The decision on bridge health condition is made and the sensitivity of variables is evaluated with the aid of the Mahalanobis–Taguchi system, a multivariate pattern recognition tool. Several observations are made as follows. For the modal parameters, although bridge damage detection can be achieved by performing Mahalanobis–Taguchi system on certain modal parameters of certain sets of measurement points, difficulties were faced in subjective selection of meaningful bridge modes and low sensitivity of the statistical pattern of the modal parameters to damage. For Nair’s damage indicator, bridge damage detection could be achieved by performing Mahalanobis–Taguchi system on Nair’s damage indicators of most sets of measurement points. As a damage indicator, Nair’s damage indicator was superior to the modal parameters. Three main advantages were observed: it does not require any subjective decision in calculating Nair’s damage indicator, thus potential human errors can be prevented and an automatic detection task can be achieved; its statistical pattern has high sensitivity to damage and, finally, it is flexible regarding the choice of sets of measurement points.
Resumo:
An assessment of the sustainability of the Irish economy has been carried out using three methodologies, enabling comparison and evaluation of the advantages and disadvantages of each, and potential synergies among them. The three measures chosen were economy-wide Material Flow Analysis (MFA), environmentally extended input-output (EE-IO) analysis and the Ecological Footprint (EF). The research aims to assess the sustainability of the Irish economy using these methods and to draw conclusions on their effectiveness in policy making both individually and in combination. A theoretical description discusses the methods and their respective advantages and disadvantages and sets out a rationale for their combined application. The application of the methods in combination has provided insights into measuring the sustainability of a national economy and generated new knowledge on the collective application of these methods. The limitations of the research are acknowledged and opportunities to address these and build on and extend the research are identified. Building on previous research, it is concluded that a complete picture of sustainability cannot be provided by a single method and/or indicator.