7 resultados para Output Analysis


Relevância:

60.00% 60.00%

Publicador:

Resumo:

An assessment of the sustainability of the Irish economy has been carried out using three methodologies, enabling comparison and evaluation of the advantages and disadvantages of each, and potential synergies among them. The three measures chosen were economy-wide Material Flow Analysis (MFA), environmentally extended input-output (EE-IO) analysis and the Ecological Footprint (EF). The research aims to assess the sustainability of the Irish economy using these methods and to draw conclusions on their effectiveness in policy making both individually and in combination. A theoretical description discusses the methods and their respective advantages and disadvantages and sets out a rationale for their combined application. The application of the methods in combination has provided insights into measuring the sustainability of a national economy and generated new knowledge on the collective application of these methods. The limitations of the research are acknowledged and opportunities to address these and build on and extend the research are identified. Building on previous research, it is concluded that a complete picture of sustainability cannot be provided by a single method and/or indicator.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analysis of the operation of a new series-L/parallel-tuned Class-E amplifier and its equivalence to the classic shunt-C/series-tuned Class-E amplifier are presented. The first reported closed form design equations for the series-L/parallel-tuned topology operating under ideal switching conditions are given, including the switch current and voltage in steady state, the circuit component values, the peak values of switch current and voltage and the power-output capability. Theoretical analysis is confirmed by numerical simulation for a 500 mW (27 dBm), 10% bandwidth, 5 V series-L/parallel-tuned, then, shunt-C/series-tuned Class-E power amplifier, operating at 2.5 GHz. Excellent agreement between theory and simulation results is achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two direct sampling correlator-type receivers for differential chaos shift keying (DCSK) communication systems under frequency non-selective fading channels are proposed. These receivers operate based on the same hardware platform with different architectures. In the first scheme, namely sum-delay-sum (SDS) receiver, the sum of all samples in a chip period is correlated with its delayed version. The correlation value obtained in each bit period is then compared with a fixed threshold to decide the binary value of recovered bit at the output. On the other hand, the second scheme, namely delay-sum-sum (DSS) receiver, calculates the correlation value of all samples with its delayed version in a chip period. The sum of correlation values in each bit period is then compared with the threshold to recover the data. The conventional DCSK transmitter, frequency non-selective Rayleigh fading channel, and two proposed receivers are mathematically modelled in discrete-time domain. The authors evaluated the bit error rate performance of the receivers by means of both theoretical analysis and numerical simulation. The performance comparison shows that the two proposed receivers can perform well under the studied channel, where the performances get better when the number of paths increases and the DSS receiver outperforms the SDS one.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the first multi vector energy analysis for the interconnected energy systems of Great Britain (GB) and Ireland. Both systems share a common high penetration of wind power, but significantly different security of supply outlooks. Ireland is heavily dependent on gas imports from GB, giving significance to the interconnected aspect of the methodology in addition to the gas and power interactions analysed. A fully realistic unit commitment and economic dispatch model coupled to an energy flow model of the gas supply network is developed. Extreme weather events driving increased domestic gas demand and low wind power output were utilised to increase gas supply network stress. Decreased wind profiles had a larger impact on system security than high domestic gas demand. However, the GB energy system was resilient during high demand periods but gas network stress limited the ramping capability of localised generating units. Additionally, gas system entry node congestion in the Irish system was shown to deliver a 40% increase in short run costs for generators. Gas storage was shown to reduce the impact of high demand driven congestion delivering a reduction in total generation costs of 14% in the period studied and reducing electricity imports from GB, significantly contributing to security of supply.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we consider the uplink of a single-cell massive multiple-input multiple-output (MIMO) system with inphase and quadrature-phase imbalance (IQI). This scenario is of particular importance in massive MIMO systems, where the deployment of lower-cost, lower-quality components is desirable to make massive MIMO a viable technology. Particularly, we investigate the effect of IQI on the performance of massive MIMO employing maximum-ratio combining (MRC) receivers. In order to study how IQI affects channel estimation, we derive a new channel estimator for the IQI-impaired model and show that IQI can substantially downgrade the performance of MRC receivers. Moreover, a low-complexity IQI compensation scheme, suitable for massive MIMO, is proposed which is based on the IQI coefficients' estimation and it is independent of the channel gain. The performance of the proposed compensation scheme is analytically evaluated by deriving a tractable approximation of the ergodic achievable rate and providing the asymptotic power scaling laws assuming transmission over Rayleigh fading channels with log-normal large-scale fading. Finally, we show that massive MIMO effectively suppresses the residual IQI effects, as long as, the compensation scheme is applied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the energy efficiency (EE) of a point-to-point rank-1 Ricean fading multiple-input-multiple-output (MIMO) channel. In particular, a tight lower bound and an asymptotic approximation for the EE of the considered MIMO system are presented, under the assumption that the channel is unknown at the transmitter and perfectly known at the receiver. Moreover, the effects of different system parameters, namely, transmit power, spectral efficiency (SE), and number of transmit and receive antennas, on the EE are analytically investigated. An important observation is that, in the high signal-to-noise ratio regime and with the other system parameters fixed, the optimal transmit power that maximizes the EE increases as the Ricean-K factor increases. On the contrary, the optimal SE and the optimal number of transmit antennas decrease as K increases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Harnessing solar energy to provide for the thermal needs of buildings is one of the most promising solutions to the global energy issue. Exploiting the additional surface area provided by the building’s façade can significantly increase the solar energy output. Developing a range of integrated and adaptable products that do not significantly affect the building’s aesthetics is vital to enabling the building integrated solar thermal market to expand and prosper. This work reviews and evaluates solar thermal facades in terms of the standard collector type, which they are based on, and their component make-up. Daily efficiency models are presented, based on a combination of the Hottel Whillier Bliss model and finite element simulation. Novel and market available solar thermal systems are also reviewed and evaluated using standard evaluation methods, based on experimentally determined parameters ISO 9806. Solar thermal collectors integrated directly into the facade benefit from the additional wall insulation at the back; displaying higher efficiencies then an identical collector offset from the facade. Unglazed solar thermal facades with high capacitance absorbers (e.g. concrete) experience a shift in peak maximum energy yield and display a lower sensitivity to ambient conditions than the traditional metallic based unglazed collectors. Glazed solar thermal facades, used for high temperature applications (domestic hot water), result in overheating of the building’s interior which can be reduced significantly through the inclusion of high quality wall insulation. For low temperature applications (preheating systems), the cheaper unglazed systems offer the most economic solution. The inclusion of brighter colour for the glazing and darker colour for the absorber shows the lowest efficiency reductions (<4%). Novel solar thermal façade solutions include solar collectors integrated into balcony rails, shading devices, louvers, windows or gutters.