97 resultados para Non-Ideal Duffing System
Resumo:
Massive multiple-input multiple-output (MIMO) systems are cellular networks where the base stations (BSs) are equipped with unconventionally many antennas, deployed on colocated or distributed arrays. Huge spatial degrees-of-freedom are achieved by coherent processing over these massive arrays, which provide strong signal gains, resilience to imperfect channel knowledge, and low interference. This comes at the price of more infrastructure; the hardware cost and circuit power consumption scale linearly/affinely with the number of BS antennas N. Hence, the key to cost-efficient deployment of large arrays is low-cost antenna branches with low circuit power, in contrast to today’s conventional expensive and power-hungry BS antenna branches. Such low-cost transceivers are prone to hardware imperfections, but it has been conjectured that the huge degrees-of-freedom would bring robustness to such imperfections. We prove this claim for a generalized uplink system with multiplicative phasedrifts, additive distortion noise, and noise amplification. Specifically, we derive closed-form expressions for the user rates and a scaling law that shows how fast the hardware imperfections can increase with N while maintaining high rates. The connection between this scaling law and the power consumption of different transceiver circuits is rigorously exemplified. This reveals that one can make the circuit power increase as p N, instead of linearly, by careful circuit-aware system design.
Resumo:
We study the influence of non-ideal boundary and initial conditions (BIC) of a temporal analysis of products (TAP) reactor model on the data (observed exit flux) analysis. The general theory of multi-response state-defining experiments for a multi-zone TAP reactor is extended and applied to model several alternative boundary and initial conditions proposed in the literature. The method used is based on the Laplace transform and the transfer matrix formalism for multi-response experiments. Two non-idealities are studied: (1) the inlet pulse not being narrow enough (gas pulse not entering the reactor in Dirac delta function shape) and (2) the outlet non-ideality due to imperfect vacuum. The effect of these non-idealities is analyzed to the first and second order of approximation. The corresponding corrections were obtained and discussed in detail. It was found that they are negligible. Therefore, the model with ideal boundary conditions is proven to be completely adequate to the description and interpretation of transport-reaction data obtained with TAP-2 reactors.
Resumo:
Non-ideal behaviour of 1-butyl-3-methylimidazolium hexafluorophosphate [bmim][PF6] in ethylene glycol monomethyl ether; CH3OCH2CH2OH (EGMME), ethylene glycol dimethyl ether; CH3OCH2CH2OCH3 (EGDME) and diethylene glycol dimethyl ether; CH3(OCH2CH2)2OCH3 (DEGDME) have been investigated over the whole composition range at T = (298.15 to 318.15) K. To gain insight into the mixing behaviour, results of density measurements were used to estimate excess molar volumes, image, apparent molar volumes, Vphi,i, partial molar volumes, image, excess partial molar volumes, image, and their limiting values at infinite dilution, image, image, and image, respectively. Volumetric results have been analyzed in the light of Prigogine–Flory–Patterson (PFP) statistical mechanical theory. Measurements of refractive indices n were also performed for all the binary mixtures over whole composition range at T = 298.15 K. Deviations in refractive indices ?phin and the deviation of molar refraction ?xR have been calculated from experimental data. Refractive indices results have been correlated with volumetric results and have been interpreted in terms of molecular interactions. Excess properties are fitted to the Redlich–Kister polynomial equation to obtain the binary coefficients and the standard errors.
Resumo:
In this paper, a data driven orthogonal basis function approach is proposed for non-parametric FIR nonlinear system identification. The basis functions are not fixed a priori and match the structure of the unknown system automatically. This eliminates the problem of blindly choosing the basis functions without a priori structural information. Further, based on the proposed basis functions, approaches are proposed for model order determination and regressor selection along with their theoretical justifications. © 2008 IEEE.
Resumo:
We show that the use of a recently proposed iterative collision model with interenvironment swaps displays a signature of strongly non-Markovian dynamics that is highly dependent on the establishment of system-environment correlations. Two models are investigated: one in which such correlations are canceled iteratively and one in which they are kept all across the dynamics. The degree of non-Markovianity, quantified using a measure based on the trace distance, is found to be much greater for all coupling strengths, when system-environment correlations are maintained.
Resumo:
Synchronisation of small distributed generation, 30 kVA–2 MVA, employing salient-pole synchronous machines is normally performed within a narrow range of tolerances for voltage, frequency and phase angle. However, there are situations when the ability to synchronise with non-ideal conditions would be beneficial. Such applications include power system islanding and rapid generator start-up. The physical process and effect of out-of-phase synchronisation is investigated both through simulation and experimental tests on a salient-pole alternator. There are many factors that affect synchronisation, but particular attention is given to synchronisation angle, voltage difference and, as generators will be loaded during islanding, the load angle. The results suggest that it would be acceptable for the maximum synchronisation angle of distributed generation to exceed that of current practice. Interesting observations on the nature of out-of-phase synchronisation are made, including some specific to small salient-pole synchronous machines. Furthermore, recommendations are made for synchronisation under different system conditions.
Resumo:
DRAM technology faces density and power challenges to increase capacity because of limitations of physical cell design. To overcome these limitations, system designers are exploring alternative solutions that combine DRAM and emerging NVRAM technologies. Previous work on heterogeneous memories focuses, mainly, on two system designs: PCache, a hierarchical, inclusive memory system, and HRank, a flat, non-inclusive memory system. We demonstrate that neither of these designs can universally achieve high performance and energy efficiency across a suite of HPC workloads. In this work, we investigate the impact of a number of multilevel memory designs on the performance, power, and energy consumption of applications. To achieve this goal and overcome the limited number of available tools to study heterogeneous memories, we created HMsim, an infrastructure that enables n-level, heterogeneous memory studies by leveraging existing memory simulators. We, then, propose HpMC, a new memory controller design that combines the best aspects of existing management policies to improve performance and energy. Our energy-aware memory management system dynamically switches between PCache and HRank based on the temporal locality of applications. Our results show that HpMC reduces energy consumption from 13% to 45% compared to PCache and HRank, while providing the same bandwidth and higher capacity than a conventional DRAM system.
Resumo:
In this paper, we consider the variable selection problem for a nonlinear non-parametric system. Two approaches are proposed, one top-down approach and one bottom-up approach. The top-down algorithm selects a variable by detecting if the corresponding partial derivative is zero or not at the point of interest. The algorithm is shown to have not only the parameter but also the set convergence. This is critical because the variable selection problem is binary, a variable is either selected or not selected. The bottom-up approach is based on the forward/backward stepwise selection which is designed to work if the data length is limited. Both approaches determine the most important variables locally and allow the unknown non-parametric nonlinear system to have different local dimensions at different points of interest. Further, two potential applications along with numerical simulations are provided to illustrate the usefulness of the proposed algorithms.
Resumo:
Germanium (Ge) does not grow a suitable oxide for MOS devices. The Ge/dielectric interface is of prime importance to the operation of photo-detectors and scaled MOSTs. Therefore there is a requirement for deposited or bonded dielectric materials. MOS capacitors have been formed on germanium substrates with three different dielectric materials. Firstly, a thermally grown and bonded silicon dioxide (SiO2) layer, secondly, SiO2 deposited by atmospheric pressure CVD ‘silox’, and thirdly a hafnium oxide (HfO2) high-k dielectric deposited by atomic layer deposition (ALD). Ge wafers used were p-type 1 0 0 2 O cm. C–V measurements have been made on all three types of capacitors to assess the interface quality. ALD HfO2 and silox both display acceptable C–V characteristics. Threshold voltage and maximum and minimum capacitance values closely match expected values found through calculation. However, the bonded SiO2 has non-ideal C–V characteristics, revealing the presence of a high density of interface states. A H2/N2 post metal anneal has a detrimental effect on C–V characteristics of HfO2 and silox dielectrics, causing a shift in the threshold voltage and rise in the minimum capacitance value. In the case of hafnium dioxide, capacitor properties can be improved by performing a plasma nitridation of the Ge surface prior to dielectric deposition.
Resumo:
Double laser pulses of duration similar to 75 ps and short laser pulses similar to 1 ps superimposed on longer duration background pulses have been shown to efficiently pump lasing in Ne-like and Ni-like ions. For the 75 ps pumping, X-ray laser output without travelling wave pumping is shown to be well-described by a model of ASE output. With I ps pumping, the X-ray laser output with different velocity travelling wave pumping is well-fitted with an extension to the ASE model allowing for travelling wave excitation of the gain along the plasma line. The model is used to investigate the production of short (<1 ps) x-ray laser pulses and the effects of non-ideal travelling wave velocities on the X-ray laser output. Resonance line spectra of emission perpendicular to the plasma line are measured and simulated. It is shown that an accurate opacity model for the more intense Ne-like ions is needed to correctly simulate the spectra.
Resumo:
Background: Patients with Barrett's oesophagus have an increased risk of oesophageal adenocarcinoma but this cancer only accounts for a small proportion of deaths in these patients. Other causes of death are reportedly raised in this group. We examined cause specific mortality among individuals in a population based Barrett's oesophagus register. Methods: We constructed a register of all patients diagnosed with columnar mucosa (including specialised intestinal metaplasia) of the oesophagus within Northern Ireland between 1993 and 1999. Deaths occurring within this cohort until 31 December 2000 were identified and mortality rates were compared with the general population. Results: Overall mortality was not raised in Barrett's patients. During 7413 person years of follow up in 2373 patients there were 253 deaths (standardised mortality ratio (SMR) 96 (95% confidence interval (CI) 84-107)). Mortality from oesophageal cancer was raised in patients with specialised intestinal metaplasia (SMR 774 (95% CI 317-1231 )) but only 4.7% of patients died from this cancer. Mortality from stroke (SMR 65 (95% CI 37-93)) was significantly lower than the general population while mortality from non-cancerous digestive system diseases was significantly higher (SMR 211 (95% CI 111-311)). Mortality rates from all other causes were similar to those of the general population. Conclusions: This study demonstrates that the overall mortality rate in patients with Barrett's oesophagus is closely similar to that of the general population. Oesophageal cancer mortality was raised but is an uncommon cause of death in these patients who also appear to have a reduced risk of death from stroke.
Resumo:
A proof-of-concept study was reported on analysis of antigen–antibody recognition based on resonant Rayleigh scattering response of single Au nanoparticles in an imaging chamber. As benefited by a traditional dark-field microscope and a spectrograph, individual Au nanoparticles (30 nm) were observed with high signal-to-noise ratio and they were effectively utilized to monitor changes in refractive index induced by specific binding of the adsorbates. Using PSA antigen as a model, a LSPR ?max shift of about 2.85 nm was recorded for a molecular binding corresponding to 0.1 pg ml-1 of the protein biomarker. This result successfully demonstrates a non-labeling detection system for proteins as well as thousands of different chemical or biological species, and it possesses a great potential as a sensitive, on-chip and multiplexing detection.
Resumo:
Modern internal combustion (IC) engines reject around two thirds of the energy provided by the fuel as low-grade waste heat. Capturing a portion of this waste heat energy and transforming it into a more useful form of energy could result in a significant reduction in fuel consumption. By using the low-grade heat, an organic Rankine cycle (ORC) can produce mechanical work from a pressurised organic fluid with the use of an expander.
Ideal gas assumptions are shown to produce significant errors in expander performance predictions when using an organic fluid. This paper details the mathematical modelling technique used to accurately model the thermodynamic processes for both ideal and non-ideal fluids within the reciprocating expander. A comparison between the two methods illustrates the extent of the errors when modelling a reciprocating piston expander. Use of the ideal gas assumptions are shown to produce an error of 55% in the prediction of power produced by the expander when operating on refrigerant R134a.
Resumo:
A proof-of-concept study was reported on analysis of antigen-antibody recognition based on resonant Rayleigh scattering response of single Au nanoparticles on a microimaging chamber. As benefited by a traditional dark-field microscope and a spectrograph, tiny 30 nm Au nanoparticles were effectively used as nanosensors to monitor changes in refractive index induced by every single binding of the adsorbates. The individual Au nanoparticles were observed with very high signal-to-noise ratio, and a LSPR ?max shift of about 2.5 nm accounting for the detection of PSA antigen with concentration as low as 0.1 pg ml-1 was recorded. This resulted in the successful demonstration of a non-labelling detection system for proteins as well as thousands of different chemical or biological species with possibility of miniaturization and multiplexing scheme.