3 resultados para Neonatal seizure detection
Resumo:
In this paper, we have developed a low-complexity algorithm for epileptic seizure detection with a high degree of accuracy. The algorithm has been designed to be feasibly implementable as battery-powered low-power implantable epileptic seizure detection system or epilepsy prosthesis. This is achieved by utilizing design optimization techniques at different levels of abstraction. Particularly, user-specific critical parameters are identified at the algorithmic level and are explicitly used along with multiplier-less implementations at the architecture level. The system has been tested on neural data obtained from in-vivo animal recordings and has been implemented in 90nm bulk-Si technology. The results show up to 90 % savings in power as compared to prevalent wavelet based seizure detection technique while achieving 97% average detection rate. Copyright 2010 ACM.
Resumo:
Background: Approximately 5-6% of all infective episodes in NICU are of viral origin. Previous studies suggest that human parechovirus (HPeV) infection presents most commonly in term infants, as a sepsis-like syndrome in which meningoencephalitis is prominent. Our aim was to study the infection rate and associated features of HPeV.
Methods: Blood samples were taken from NICU babies greater than 48 hours old, who were being investigated for late onset sepsis. Clinical and laboratory data were collected at the time of the suspected sepsis episode. Samples were tested using universal primers and probe directed at the 5'-untranslated region of the HPeV genome by reverse transcriptase PCR. Results were confirmed by electrophoresis and DNA sequencing.
Results: HPeV was detected in 11 of 84 samples (13%). These infants had a mean (interquartile range, IQR) gestational age of 28.9 (26.9 - 30.6) weeks and mean birth weight of 1.26 (SD = 0.72) kg. The median day of presentation was 16 (IQR: 11-27). These characteristics were similar to the infants without positive viral detection. Six infants presented with respiratory signs. One infant presented with signs of meningitis. Six of the 11 episodes of HPeV infection occurred during the winter months (December - February). No HPeV positive infants had abnormal findings on their 28-day cranial ultrasound examination.
Conclusions: We found a HPeV infection rate of 13% in infants being tested for late onset sepsis. HPeV should be considered as a possible cause of sepsis-like symptoms in preterm infants.
Resumo:
We describe, for the first time the use of hydrogel-forming microneedle (MN) arrays for minimally-invasive extraction and quantification of drug substances and glucose from skin in vitro and in vivo. MN prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) (11.1% w/w) and poly(ethyleneglycol) 10,000 daltons (5.6% w/w) and crosslinked by esterification swelled upon skin insertion by uptake of fluid. Post-removal, theophylline and caffeine were extracted from MN and determined using HPLC, with glucose quantified using a proprietary kit. In vitro studies using excised neonatal porcine skin bathed on the underside by physiologically-relevant analyte concentrations showed rapid (5 min) analyte uptake. For example, mean concentrations of 0.16 μg/mL and 0.85 μg/mL, respectively, were detected for the lowest (5 μg/mL) and highest (35 μg/mL) Franz cell concentrations of theophylline after 5 min insertion. A mean concentration of 0.10 μg/mL was obtained by extraction of MN inserted for 5 min into skin bathed with 5 μg/mL caffeine, while the mean concentration obtained by extraction of MN inserted into skin bathed with 15 μg/mL caffeine was 0.33 μg/mL. The mean detected glucose concentration after 5 min insertion into skin bathed with 4 mmol/L was 19.46 nmol/L. The highest theophylline concentration detected following extraction from a hydrogel-forming MN inserted for 1 h into the skin of a rat dosed orally with 10 mg/kg was of 0.363 μg/mL, whilst a maximum concentration of 0.063 μg/mL was detected following extraction from a MN inserted for 1 h into the skin of a rat dosed with 5 mg/kg theophylline. In human volunteers, the highest mean concentration of caffeine detected using MN was 91.31 μg/mL over the period from 1 to 2 h post-consumption of 100 mg Proplus® tablets. The highest mean blood glucose level was 7.89 nmol/L detected 1 h following ingestion of 75 g of glucose, while the highest mean glucose concentration extracted from MN was 4.29 nmol/L, detected after 3 hours skin insertion in human volunteers. Whilst not directly correlated, concentrations extracted from MN were clearly indicative of trends in blood in both rats and human volunteers. This work strongly illustrates the potential of hydrogel-forming MN in minimally-invasive patient monitoring and diagnosis. Further studies are now ongoing to reduce clinical insertion times and develop mathematical algorithms enabling determination of blood levels directly from MN measurements.