2 resultados para National System for Evaluation of Higher Education (SINAES in Portuguese)-Brazil


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silica additives in bone substitute materials are topical, clinically interesting and have significant support in the Orthopaedic field. Biosilica, e.g isolated from diatoms, has many advantages over its synthetic counterparts, e.g. it is amorphous, thus will be absorbed by the body, however, issues such as purity, presence of endotoxins and cytotoxicity need to be addressed before it can be further exploited. Biosilica isolated from Cyclotella Meneghiniana was then tested in a mouse model, to test the immunological response, organ toxicity (kidney, spleen, liver) and route of metabolism/excretion of silica. Five-week-old Balb-c mice were injected subcutaneously with a single high dose (50mg/ml) of Si-frustules, Si-frustules + organic linker and vehicle only control. Animals were sacrificed at 1d and 28d. The animal studies were conducted under an ethically approved protocol at Queen’s University, Belfast. The animals showed no adverse stress during the experiment and remained healthy until sacrifice. Blood results using ICP-OES analysis suggest the frustules were metabolized between comparator groups at different rates, and clearly showed elevated levels of silicon in groups injected with frustules relative to control. The histology of organs showed no variation in morphology of mice injected frustules relative compared to the control group.
Acknowledgements: The authors would like to thank Marie Curie International Outgoing Fellowships from the EU and Beaufort Marine Biodiscovery Award as part of the Marine Biotechnology Ireland Programme for providing financial support to this project.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increasing energy efficiency in the residential sector, while maintaining adequate home ventilation for health and well-being, is proving to be a challenge. This study assesses the efficacy of passive ventilation strategies designed to comply with building regulations and imposed after housing energy-efficiency retrofits. In particular, it focuses on the provision of ventilation using background through-wall vents, which remains a common strategy in a number of European countries including Ireland and the UK, where vent sizes, related to floor area, are stipulated in building regulations. A collective of social housing, with background through-wall vents installed post thermal retrofit, is taken as a case study. These homes are modelled to interrogate the impact of the passive ventilation strategy on house air exchange rate and thermal heating energy loads. The reaction of occupants to through-wall vent installation is decidedly negative and many block vents to limit thermal discomfort and heat loss. Simulation studies show significant external air ingress through vents. A wide range of effective air change rates are observed when vents are sized without reference to building airtightness, and significant energy penalties result for the leakier homes. This study evaluates the provision of passive through-wall ventilation as part of a retrofit programme and shows it to have a number of drawbacks that may impact on the health of the building and its occupants and ultimately be at odds with the aims of achieving energy efficiency in the residential sector.